Plan Review Details - Permit 19100694
Plan Review Stops For Permit 19100694
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-12-13 Cont ID  
Sent By jleahy Date 2019-12-13 Time 08:29 Rev Time 0.00
Received By jleahy Date 2019-12-13 Time 08:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-10-28 Cont ID  
Sent By pvalenti Date 2019-10-28 Time 11:21 Rev Time 0.00
Received By pvalenti Date 2019-10-28 Time 11:21 Sent To  
Notes
2019-10-28 11:25:42***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1 MORE INFORMATION IS REQUIRED. PLEASE
 PROVIDE ENGINEER APPROVED SLAB AND CONNECTION DETAILS
 INCLUDING BOLT SIZES AND QUANTITIES.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-12-13 Cont ID  
Sent By jleahy Date 2019-12-13 Time 08:29 Rev Time 0.00
Received By jleahy Date 2019-12-13 Time 08:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-10-29 Cont ID  
Sent By jleahy Date 2019-10-29 Time 07:27 Rev Time 0.00
Received By jleahy Date 2019-10-29 Time 07:27 Sent To  
Notes
2019-10-29 07:29:00FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 VALUE FOR THIS SIZE GENERATOR IS USUALLY $12,500 TO
 $16,000 PLEASE ADJUST THE VALUE FOR THE WORK AND
 MATERIAL.
  
 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS
 (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE
 BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING,
 MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK,
 ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-10-29 Cont ID  
Sent By rfalcone Date 2019-10-29 Time 07:29 Rev Time 0.00
Received By jleahy Date 2019-10-15 Time 13:58 Sent To  
Notes
2019-10-16 13:58:21ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date 2019-10-17 Cont ID  
Sent By rfalcone Date 2019-10-17 Time 09:37 Rev Time 0.00
Received By rfalcone Date 2019-10-17 Time 09:38 Sent To B
Notes
***NONE***