| 2019-10-15 13:23:50 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM |
| | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) |
| | 805-6724 |
| | [email protected] |
| | |
| | 1ST REVIEW: FBC 2017 6TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | YOU MAY RESUBMIT PRINTABLE DOCUMENTS ALONG WITH A |
| | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO |
| | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT |
| | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE |
| | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: |
| | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B |
| | UILDING-PERMIT-FORMS |
| | |
| | 1.FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF |
| | PROTECTIVE DEVICES OR ASSEMBLIES: PLEASE CORRECT COLUMN |
| | HEADING ?ANCHOR SPACING?; PROVIDE INFORMATION FROM PAGE |
| | FROM PAGE 12 OF FL1850-R11. EXAMPLE: POURED CONCRETE; |
| | (A) WALL MOUNTING HEADER W/ (12); MAXIMUM A.S.D. DESIGN |
| | PRESSURE RATING (P.S.F.) 60 OR LESS, MAXIMUM SPAN |
| | 12?-0?; TAPCON WITH ADVANCED THREADFORM TECHNOLOGY; |
| | ANCHOR SPACING 5.5? WITH A FACTOR OF .9 IS 4.95?. |
| | EXAMPLE: POURED CONCRETE; (D) WALL SILL MOUNTING W/ |
| | (12); MAXIMUM A.S.D. DESIGN PRESSURE RATING (P.S.F.) 60 |
| | OR LESS, MAXIMUM SPAN 12?-0?; TAPCON WITH ADVANCED |
| | THREADFORM TECHNOLOGY; THIS CONNECTION IS NOT ALLOWED. |
| | EXAMPLE: POURED CONCRETE; (D) WALL SILL MOUNTING W/ |
| | (12); MAXIMUM A.S.D. DESIGN PRESSURE RATING (P.S.F.) 40 |
| | OR LESS, MAXIMUM SPAN 12?-0?; TAPCON WITH ADVANCED |
| | THREADFORM TECHNOLOGY; ANCHOR SPACING 7? WITH A FACTOR |
| | OF .9 IS 6.3?. |
| | 2. FBC R 310.4. REVISE PLAN TO SHOW REQUIRED MEANS OF |
| | EGRESS. INCLUDE ROOM DESIGNATION. |
| | |