Plan Review Details - Permit 19100568
Plan Review Stops For Permit 19100568
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-05-26 Cont ID  
Sent By pvalenti Date 2020-05-26 Time 08:43 Rev Time 0.00
Received By pvalenti Date 2020-05-26 Time 07:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-03-09 Cont ID  
Sent By dbattles Date 2020-03-09 Time 09:38 Rev Time 0.00
Received By dbattles Date 2020-03-09 Time 09:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-01-28 Cont ID  
Sent By dbattles Date 2020-01-28 Time 14:55 Rev Time 0.00
Received By dbattles Date 2020-01-28 Time 14:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-10-28 Cont ID  
Sent By dbattles Date 2019-10-28 Time 08:06 Rev Time 0.00
Received By dbattles Date 2019-10-25 Time 14:54 Sent To  
Notes
2019-10-28 08:08:08BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19100568
 REVIEWED: OCTOBER 25, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1. 501 FBC[EXISTING] LEVEL OF ALTERATION FOR WORK BEING
 PERFORMED.
 - PLEASE CHANGE TO LEVEL 3 ALTERATION. SINCE THE WORK
 AREA IS OVER 50% OF THE BUILDING AREA.
  
 2. 320.1 FBC[R] ALL NEW SINGLE-FAMILY HOUSES, DUPLEXES,
 TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL PROVIDE AT
 LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE
 PRIVACY, WHERE BATHROOMS ARE PROVIDED ON HABITABLE
 GRADE LEVELS, WITH A DOOR THAT HAS A 29-INCH CLEAR
 OPENING. HOWEVER, IF ONLY A TOILET ROOM IS PROVIDED AT
 GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR
 OPENING OF NOT LESS THAN 29 INCHES.
 - WHAT IS THE WIDTH OF CLEAR OPENING AT BATHROOM DOORS?
 WILL ONE OF THEM PROVIDE MINIMUM OF 29 INCHES?
  
 3. 311.2 FBC[R] NOT LESS THAN ONE EGRESS DOOR SHALL BE
 PROVIDED FOR EACH DWELLING UNIT. THE EGRESS DOOR SHALL
 BE SIDE-HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT
 LESS THAN 32 INCHES WHERE MEASURED BETWEEN THE FACE OF
 THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES
 (1.57 RAD). THE CLEAR HEIGHT OF THE DOOR OPENING SHALL
 BE NOT LESS THAN 78 INCHES IN HEIGHT MEASURED FROM THE
 TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP. OTHER
 DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE
 MINIMUM DIMENSIONS. EGRESS DOORS SHALL BE READILY
 OPENABLE FROM INSIDE THE DWELLING WITHOUT THE USE OF A
 KEY OR SPECIAL KNOWLEDGE OR EFFORT.
  
 4. 311.3 FBC[R] FLOORS AND LANDINGS AT EXTERIOR DOORS.
 THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH
 EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT
 LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A
 DIMENSION OF NOT LESS THAN 36 INCHES (914 MM) MEASURED
 IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR
 LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS
 HORIZONTAL (2 PERCENT).
 - PROVIDE LANDING AT EXTERIOR SIDE OF DOOR IF GREATER
 THAN 2 RISERS PROVIDED.
  
 5. 408.1 FBC[R] PROVIDE VENTING CALCULATIONS FOR UNDER
 FLOOR SPACE, OR FOLLOW REQUIREMENTS FOR UNVENTED.
 - IS THE UNDER FLOOR SPACE VENTED OR UNVENTED? IF
 UNVENTED SEE SECTION R408.3 UNVENTED CRAWL SPACE.
  
 6. 408.4 FBC[R] PROVIDE ACCESS TO THE UNDER FLOOR SPACE
 18X24 MINIMUM.
 - THIS IS REQUIRED FOR VENTED OR UNVENTED.
  
 7. 806 FBC[R] SUPPLY VENTING CALCULATIONS FOR THE ATTIC
 AND HOW THE AREA OF VENTING WILL BE ACHIEVED, OR FOLLOW
 R806.5 FOR UNVENTED.
 - IS THE ATTIC TO BE VENTED OR UNVENTED?
  
 8. 806.5 FBC[R] UNVENTED ATTIC AND UNVENTED ENCLOSED
 RAFTER ASSEMBLIES. 5.1.2. WHERE AIR-PERMEABLE
 INSULATION IS PROVIDED INSIDE THE BUILDING THERMAL
 ENVELOPE, IT SHALL BE INSTALLED IN ACCORDANCE WITH
 SECTION 5.1.1. IN ADDITION TO THE AIR-PERMEABLE
 INSULATION INSTALLED DIRECTLY BELOW THE STRUCTURAL
 SHEATHING, RIGID BOARD OR SHEET INSULATION SHALL BE
 INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHEATHING
 IN ACCORDANCE WITH THE R-VALUES IN TABLE R806.5 FOR
 CONDENSATION CONTROL.
 - IF UNVENTED PLEASE REVIEW THIS SECTION FOR AIR
 PERMEABLE INSULATION AT ROOF DECK.
  
 9. [RAS 117]PROVIDE ENGINEERING FOR ENHANCED NAILING AS
 STATED IN PRODUCT APPROVAL UNDER GENERAL LIMITATIONS
 #7.
 - THE PRODUCT APPROVAL FOR FLAT ROOFING REQUIRES
 ENGINEERING FOR ENHANCED NAILING OF ZONES 2 AND 3.
 ALSO, SELECT FASTENING OPTION TO BE USED FROM SHEET 51
 OR 52.
  
 NOTES:
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS.
 FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE
 REQUIRED.
  
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2021-02-08 Cont ID  
Sent By ppetty Date 2021-02-08 Time 11:09 Rev Time 0.00
Received By ppetty Date 2021-02-08 Time 11:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2020-07-22 Cont ID  
Sent By ppetty Date 2020-07-22 Time 12:27 Rev Time 0.00
Received By ppetty Date 2020-07-22 Time 12:27 Sent To  
Notes
2020-07-22 11:42:44CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. CORRECTED
 2. CORRECTED
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3 (NOT PROVIDED.)(3RD REVIEW: STILL NOT
 PROVIDED.)
 4. CORRECTED.
 5. CORRECTED.
 6. CORRECTED
 7. CORRECTED.
 8. CORRECTED.
 9. CORRECTED.
 10. CORRECTED.
 11. CORRECTED
 12. CORRECTED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2020-05-27 Cont ID  
Sent By ppetty Date 2020-05-27 Time 08:02 Rev Time 0.00
Received By ppetty Date 2020-05-27 Time 07:59 Sent To  
Notes
2020-05-27 08:02:39CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. CORRECTED
 2. CORRECTED
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3 (NOT PROVIDED.)(3RD REVIEW: STILL NOT
 PROVIDED.)
 4. CORRECTED.
 5. CORRECTED.
 6. RISER DIAGRAM SHOWS A FEED FROM THE METER TO THE
 INTERIOR PANEL WHICH IS LOCATED IN THE HALLWAY.
 CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR
 DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE
 IN THIS FASHION. PROVIDE EITHER A MAIN ON THE OUTSIDE
 OF THE HOME, OR INSTALL THE CONDUCTORS UNDER THE SLAB.
 IF THERE IS A DISCONNECT AT THE METER, THE CONDUIT TO
 THE INTERIOR PANEL SHALL INCLUDE AN EQUIPMENT GROUNDING
 CONDUCTOR. PROVIDE CORRECTIONS. NEC 230.70, 250.6,
 250.118; FBC RE E3601.6 (NOT CORRECTED.)(3RD REVIEW:
 STILL NOT CORRECTED.)
 7. CORRECTED.
 8. CORRECTED.
 9. CORRECTED.
 10. CORRECTED.
 11. CORRECTED
 12. CORRECTED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2020-03-06 Cont ID  
Sent By jpearson Date 2020-03-06 Time 15:20 Rev Time 0.00
Received By jpearson Date 2020-03-06 Time 15:20 Sent To  
Notes
2020-03-06 15:07:59CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. AFCI PROTECTION DETAILED IN NEW ELECTRIC NOTE IS NOT
 CODE COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY
 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS
 INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS,
 LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,
 SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS,
 LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI
 PROTECTED. THIS INCLUDES LIGHTING AND POWER OUTLETS AND
 RECEPTACLES. SOME AREAS REQUIRE BOTH AFCI AND GFCI
 PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12; FBC
 RE E3902; FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS
 APPLICABLE. (NOT CORRECTED.)(3RD REVIEW: NOTE IS
 CORRECTED IN ONE LOCATION, BUT NOT THE OTHER. CORRECT
 DISCREPANCY.)
 2. UNDER NEW ELECTRIC NOTE AND NOTE 14, THESE NOTES
 STATE THAT RECEPTACLES SHALL BE TAMPER RESISTANT PER
 NEC 406.11. THIS CODE SECTION DOES NOT APPLY TO TAMPER
 RESISTANT RECEPTACLES. PROVIDE CORRECTION. NEC 406.12;
 FBC RE E4002.14 (NOT CORRECTED.)(3RD REVIEW: NOTE IS
 CORRECTED IN ONE LOCATION, BUT NOT THE OTHER. CORRECT
 DISCREPANCY.)
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3 (NOT PROVIDED.)(3RD REVIEW: STILL NOT
 PROVIDED.)
 4. CORRECTED.
 5. CORRECTED.
 6. RISER DIAGRAM SHOWS A FEED FROM THE METER TO THE
 INTERIOR PANEL WHICH IS LOCATED IN THE HALLWAY.
 CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR
 DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE
 IN THIS FASHION. PROVIDE EITHER A MAIN ON THE OUTSIDE
 OF THE HOME, OR INSTALL THE CONDUCTORS UNDER THE SLAB.
 IF THERE IS A DISCONNECT AT THE METER, THE CONDUIT TO
 THE INTERIOR PANEL SHALL INCLUDE AN EQUIPMENT GROUNDING
 CONDUCTOR. PROVIDE CORRECTIONS. NEC 230.70, 250.6,
 250.118; FBC RE E3601.6 (NOT CORRECTED.)(3RD REVIEW:
 STILL NOT CORRECTED.)
 7. CORRECTED.
 8. CORRECTED.
 9. CORRECTED.
 10. CORRECTED.
 11. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. LOAD CALCULATION PROVIDED IS NOT CODE COMPLIANT.
 NEC 220; FBC RE E3602.2 (NOT PROVIDED. THERE ARE
 SEVERAL PROBLEMS WITH CALCULATION. ALSO, WHAT IS THE
 SIZE OF THE TANKLESS WATER HEATER BEING USED. PANEL
 SCHEDULE SAYS IT IS 3500 VA, BUT THIS IS NOT ONE OF THE
 SIZES SHOWN ON CUT SHEET PROVIDED.)(3RD REVIEW: STILL
 NOT CORRECTED. CALCULATION SHOULD BE OF THE TYPE FOR A
 DWELLING UNIT, AS SPEICIFED IN FBC RE 3602.2)
 12. CORRECTED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-01-31 Cont ID  
Sent By jpearson Date 2020-01-31 Time 14:18 Rev Time 0.00
Received By jpearson Date 2020-01-31 Time 14:18 Sent To  
Notes
2020-01-31 13:44:09CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. AFCI PROTECTION DETAILED IN NEW ELECTRIC NOTE IS NOT
 CODE COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY
 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS
 INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS,
 LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,
 SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS,
 LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI
 PROTECTED. THIS INCLUDES LIGHTING AND POWER OUTLETS AND
 RECEPTACLES. SOME AREAS REQUIRE BOTH AFCI AND GFCI
 PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12; FBC
 RE E3902; FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS
 APPLICABLE. (NOT CORRECTED.)
 2. UNDER NEW ELECTRIC NOTE AND NOTE 14, THESE NOTES
 STATE THAT RECEPTACLES SHALL BE TAMPER RESISTANT PER
 NEC 406.11. THIS CODE SECTION DOES NOT APPLY TO TAMPER
 RESISTANT RECEPTACLES. PROVIDE CORRECTION. NEC 406.12;
 FBC RE E4002.14 (NOT CORRECTED.)
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3 (NOT PROVIDED.)
 4. CORRECTED.
 5. RISER DIAGRAM CONFLICTS WITH PANEL SCHEDULE. IS
 PANEL A A PANEL WITH A MAIN BREAKER, OR IS IT MAIN LUG
 ONLY? PROVIDE CLARIFICATIONS AND CORRECTIONS. NEC
 215.5; WPB FBC 107.2.1 (NOT CORRECTED.)
 6. RISER DIAGRAM SHOWS A FEED FROM THE METER TO THE
 INTERIOR PANEL WHICH IS LOCATED IN THE HALLWAY.
 CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR
 DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE
 IN THIS FASHION. PROVIDE EITHER A MAIN ON THE OUTSIDE
 OF THE HOME, OR INSTALL THE CONDUCTORS UNDER THE SLAB.
 IF THERE IS A DISCONNECT AT THE METER, THE CONDUIT TO
 THE INTERIOR PANEL SHALL INCLUDE AN EQUIPMENT GROUNDING
 CONDUCTOR. PROVIDE CORRECTIONS. NEC 230.70, 250.6,
 250.118; FBC RE E3601.6 (NOT CORRECTED.)
 7. CORRECTED.
 8. CORRECTED.
 9. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10 (NOT PROVIDED.)
 10. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1 (NOT PROVIDED.)
 11. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. LOAD CALCULATION PROVIDED IS NOT CODE COMPLIANT.
 NEC 220; FBC RE E3602.2 (NOT PROVIDED. THERE ARE
 SEVERAL PROBLEMS WITH CALCULATION. ALSO, WHAT IS THE
 SIZE OF THE TANKLESS WATER HEATER BEING USED. PANEL
 SCHEDULE SAYS IT IS 3500 VA, BUT THIS IS NOT ONE OF THE
 SIZES SHOWN ON CUT SHEET PROVIDED.)
 12. CORRECTED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-10-31 Cont ID  
Sent By jpearson Date 2019-10-31 Time 15:13 Rev Time 0.00
Received By jpearson Date 2019-10-31 Time 06:37 Sent To  
Notes
2019-10-31 15:13:19CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. AFCI PROTECTION DETAILED IN NEW ELECTRIC NOTE IS NOT
 CODE COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY
 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS
 INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS,
 LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,
 SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS,
 LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI
 PROTECTED. THIS INCLUDES LIGHTING AND POWER OUTLETS AND
 RECEPTACLES. SOME AREAS REQUIRE BOTH AFCI AND GFCI
 PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12; FBC
 RE E3902; FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS
 APPLICABLE.
 2. UNDER NEW ELECTRIC NOTE AND NOTE 14, THESE NOTES
 STATE THAT RECEPTACLES SHALL BE TAMPER RESISTANT PER
 NEC 406.11. THIS CODE SECTION DOES NOT APPLY TO TAMPER
 RESISTANT RECEPTACLES. PROVIDE CORRECTION. NEC 406.12;
 FBC RE E4002.14
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3
 4. PROVIDE AIC RATING OF ANY SERVICE DISCONNECTS AND
 PANELS. NEC 110.3, 110.9; FBC RE E3606.3
 5. RISER DIAGRAM CONFLICTS WITH PANEL SCHEDULE. IS
 PANEL A A PANEL WITH A MAIN BREAKER, OR IS IT MAIN LUG
 ONLY? PROVIDE CLARIFICATIONS AND CORRECTIONS. NEC
 215.5; WPB FBC 107.2.1
 6. RISER DIAGRAM SHOWS A FEED FROM THE METER TO THE
 INTERIOR PANEL WHICH IS LOCATED IN THE HALLWAY.
 CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR
 DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE
 IN THIS FASHION. PROVIDE EITHER A MAIN ON THE OUTSIDE
 OF THE HOME, OR INSTALL THE CONDUCTORS UNDER THE SLAB.
 IF THERE IS A DISCONNECT AT THE METER, THE CONDUIT TO
 THE INTERIOR PANEL SHALL INCLUDE AN EQUIPMENT GROUNDING
 CONDUCTOR. PROVIDE CORRECTIONS. NEC 230.70, 250.6,
 250.118; FBC RE E3601.6
 7. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM
 BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET
 FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE
 R314.3(4), NFPA 72:29.8.3.4
 8. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1
 9. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 10. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 11. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. LOAD CALCULATION PROVIDED IS NOT CODE COMPLIANT.
 NEC 220; FBC RE E3602.2
 12. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR
 SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE
 EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2020-05-22 Cont ID  
Sent By aborngra Date 2020-05-22 Time 10:41 Rev Time 0.00
Received By aborngra Date 2020-05-22 Time 10:40 Sent To B
Notes
2020-05-22 10:41:08THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 AMENDMENT(S) AND CONDITION(S):
  
 THE FOLLOWING ITEMS ARE NOT APPROVED WITH THIS PERMIT:
 A. A SEPARATE DEMOLITION PERMIT IS REQUIRED WITH
 INTERIOR AND EXTERIOR PHOTOS SUBMITTED FOR DEMOLITION
 OF THE ACCESSORY STRUCTURE. ADDITIONAL REQUIREMENTS MAY
 BE NECESSARY.
 B. A SEPARATE FENCE PERMIT IS REQUIRED.
  
 THE FOLLOWING CONDITION(S) OF APPROVAL TO THE PERMIT:
 1. THE NEW WINDOW TO BE INSTALLED SHALL HAVE CLEAR
 GLASS (NO LOW-E COATING, TINTED GLASS, OR PRIVACY
 GLASS) AND MATCH THE INSET/DEPTH/LOCATION OF THE OTHER
 ORIGINAL WINDOWS WITH THIS WINDOW FRAME OPENING. IF THE
 EXISTING WINDOWS AND EXTERIOR DOORS CANNOT BE REPAIRED
 AND NEED TO BE REPLACED. A SEPARATE PERMIT WILL BE
 REQUIRED TO BE APPROVED AND ISSUED PRIOR TO
 INSTALLATION.
 2. THE SIDING APPEARS TO BE CHANNEL BEVEL SIDING
 (PROFILE) ON THE ORIGINAL PORTION OF THE STRUCTURE. THE
 EXISTING SIDING SHALL BE REPAIRED, WHERE THE EXISTING
 SIDING HAS DETERIORATED TO THE POINT OF BEING UNABLE TO
 BE REPAIRED, IT MAY BE REPLACED IN KIND WITH CYPRESS
 SIDING WITH MATCHING WIDTH AND PROFILE. IF MORE THAN
 49% OF THE EXISTING SIDING NEEDS TO BE REPLACED, THE
 PROPERTY OWNER, CONTRACTOR, OR ASSOCIATED PARTY IS
 REQUIRED TO APPLY FOR A CERTIFICATE OF APPROPRIATENESS
 (COA) APPLICATION. THE SUBMITTED SIDING INFORMATION
 SHOWS A BEVEL PROFILE. A BEVEL PROFILE IS APPROPRIATE
 FOR THE REAR ADDITION THAT CURRENTLY DOES NOT HAVE
 SIDING ON IT. IF THE ORIGINAL PORTION OF THE STRUCTURE
 HAS A BEVEL PROFILE.
  
 SPANISH TRANSLATION COURTESY OF GOOGLE TRANSLATE
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
  
 EL PERMISO HA SIDO APROBADO CON LAS SIGUIENTES
 ENMIENDAS Y CONDICIONES:
  
 LOS SIGUIENTES ART?CULOS NO EST?N APROBADOS CON ESTE
 PERMISO:
 A. SE REQUIERE UN PERMISO DE DEMOLICI?N POR SEPARADO
 CON FOTOS INTERIORES Y EXTERIORES ENVIADAS PARA LA
 DEMOLICI?N DE LA ESTRUCTURA ACCESORIA. PUEDEN SER
 NECESARIOS REQUISITOS ADICIONALES.
 SI. SE REQUIERE UN PERMISO DE VALLA SEPARADO.
  
 LAS SIGUIENTES CONDICIONES DE APROBACI?N DEL PERMISO:
 1. LA NUEVA VENTANA QUE SE INSTALAR? DEBE TENER VIDRIO
 TRANSPARENTE (SIN RECUBRIMIENTO DE BAJA EMISIVIDAD,
 VIDRIO TINTADO O VIDRIO DE PRIVACIDAD) Y DEBE COINCIDIR
 CON LA INSERCI?N / PROFUNDIDAD / UBICACI?N DE LAS OTRAS
 VENTANAS ORIGINALES CON ESTA ABERTURA DEL MARCO DE LA
 VENTANA. SI LAS VENTANAS Y PUERTAS EXTERIORES
 EXISTENTES NO PUEDEN REPARARSE Y DEBEN REEMPLAZARSE. SE
 REQUERIR? UN PERMISO POR SEPARADO PARA SER APROBADO Y
 EMITIDO ANTES DE LA INSTALACI?N.
 2. EL REVESTIMIENTO PARECE SER UN REVESTIMIENTO DE
 BISEL DE CANAL (PERFIL) EN LA PORCI?N ORIGINAL DE LA
 ESTRUCTURA. EL REVESTIMIENTO EXISTENTE DEBE REPARARSE,
 DONDE EL REVESTIMIENTO EXISTENTE SE HA DETERIORADO
 HASTA EL PUNTO DE NO PODER REPARARSE, PUEDE
 REEMPLAZARSE EN ESPECIE CON REVESTIMIENTO DE CIPR?S CON
 EL MISMO ANCHO Y PERFIL. SI M?S DEL 49% DEL
 REVESTIMIENTO EXISTENTE NECESITA SER REEMPLAZADO, SE
 REQUIERE QUE EL PROPIETARIO, EL CONTRATISTA O LA PARTE
 ASOCIADA SOLICITE UNA SOLICITUD DE CERTIFICADO DE
 APROPIACI?N (COA). LA INFORMACI?N DE REVESTIMIENTO
 PRESENTADA MUESTRA UN PERFIL DE BISEL. UN PERFIL DE
 BISEL ES APROPIADO PARA LA ADICI?N POSTERIOR QUE
 ACTUALMENTE NO TIENE REVESTIMIENTO. SI LA PORCI?N
 ORIGINAL DE LA ESTRUCTURA TIENE UN PERFIL DE BISEL.
  
 TRADUCCI?N AL ESPA?OL CORTES?A DE GOOGLE TRANSLATE
  
 PARA UNA RESPUESTA M?S R?PIDA, ENV?E UN CORREO
 ELECTR?NICO A AARON BORNGRABER, PLANIFICADOR DE
 PRESERVACI?N HIST?RICA A [email protected].
  
 AARON BORNGRABER
 PLANIFICADOR DE PRESERVACI?N HIST?RICA
 CIUDAD DE WEST PALM BEACH - SERVICIOS DE DESARROLLO
 T: 561-822-1428
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2020-02-26 Cont ID  
Sent By aborngra Date 2020-02-26 Time 11:11 Rev Time 0.00
Received By aborngra Date 2020-02-25 Time 10:02 Sent To PC
Notes
2020-02-26 11:11:10THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 AMENDMENT(S) AND CONDITION(S):
  
 THE FOLLOWING ITEMS ARE NOT APPROVED WITH THIS PERMIT:
 A. A SEPARATE DEMOLITION PERMIT IS REQUIRED WITH
 INTERIOR AND EXTERIOR PHOTOS SUBMITTED FOR DEMOLITION
 OF THE ACCESSORY STRUCTURE. ADDITIONAL REQUIREMENTS MAY
 BE NECESSARY.
 B. A SEPARATE FENCE PERMIT IS REQUIRED.
  
 THE FOLLOWING CONDITION(S) OF APPROVAL TO THE PERMIT:
 1. THE NEW WINDOW TO BE INSTALLED SHALL HAVE CLEAR
 GLASS (NO LOW-E COATING, TINTED GLASS, OR PRIVACY
 GLASS) AND MATCH THE INSET/DEPTH/LOCATION OF THE OTHER
 ORIGINAL WINDOWS WITH THIS WINDOW FRAME OPENING. IF THE
 EXISTING WINDOWS AND EXTERIOR DOORS CANNOT BE REPAIRED
 AND NEED TO BE REPLACED. A SEPARATE PERMIT WILL BE
 REQUIRED TO BE APPROVED AND ISSUED PRIOR TO
 INSTALLATION.
 2. THE SIDING APPEARS TO BE CHANNEL BEVEL SIDING
 (PROFILE) ON THE ORIGINAL PORTION OF THE STRUCTURE. THE
 EXISTING SIDING SHALL BE REPAIRED, WHERE THE EXISTING
 SIDING HAS DETERIORATED TO THE POINT OF BEING UNABLE TO
 BE REPAIRED, IT MAY BE REPLACED IN KIND WITH CYPRESS
 SIDING WITH MATCHING WIDTH AND PROFILE. IF MORE THAN
 49% OF THE EXISTING SIDING NEEDS TO BE REPLACED, THE
 PROPERTY OWNER, CONTRACTOR, OR ASSOCIATED PARTY IS
 REQUIRED TO APPLY FOR A CERTIFICATE OF APPROPRIATENESS
 (COA) APPLICATION. THE SUBMITTED SIDING INFORMATION
 SHOWS A BEVEL PROFILE. A BEVEL PROFILE IS APPROPRIATE
 FOR THE REAR ADDITION THAT CURRENTLY DOES NOT HAVE
 SIDING ON IT. IF THE ORIGINAL PORTION OF THE STRUCTURE
 HAS A BEVEL PROFILE.
  
 SPANISH TRANSLATION COURTESY OF GOOGLE TRANSLATE
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
  
 EL PERMISO HA SIDO APROBADO CON LAS SIGUIENTES
 ENMIENDAS Y CONDICIONES:
  
 LOS SIGUIENTES ART?CULOS NO EST?N APROBADOS CON ESTE
 PERMISO:
 A. SE REQUIERE UN PERMISO DE DEMOLICI?N POR SEPARADO
 CON FOTOS INTERIORES Y EXTERIORES ENVIADAS PARA LA
 DEMOLICI?N DE LA ESTRUCTURA ACCESORIA. PUEDEN SER
 NECESARIOS REQUISITOS ADICIONALES.
 SI. SE REQUIERE UN PERMISO DE VALLA SEPARADO.
  
 LAS SIGUIENTES CONDICIONES DE APROBACI?N DEL PERMISO:
 1. LA NUEVA VENTANA QUE SE INSTALAR? DEBE TENER VIDRIO
 TRANSPARENTE (SIN RECUBRIMIENTO DE BAJA EMISIVIDAD,
 VIDRIO TINTADO O VIDRIO DE PRIVACIDAD) Y DEBE COINCIDIR
 CON LA INSERCI?N / PROFUNDIDAD / UBICACI?N DE LAS OTRAS
 VENTANAS ORIGINALES CON ESTA ABERTURA DEL MARCO DE LA
 VENTANA. SI LAS VENTANAS Y PUERTAS EXTERIORES
 EXISTENTES NO PUEDEN REPARARSE Y DEBEN REEMPLAZARSE. SE
 REQUERIR? UN PERMISO POR SEPARADO PARA SER APROBADO Y
 EMITIDO ANTES DE LA INSTALACI?N.
 2. EL REVESTIMIENTO PARECE SER UN REVESTIMIENTO DE
 BISEL DE CANAL (PERFIL) EN LA PORCI?N ORIGINAL DE LA
 ESTRUCTURA. EL REVESTIMIENTO EXISTENTE DEBE REPARARSE,
 DONDE EL REVESTIMIENTO EXISTENTE SE HA DETERIORADO
 HASTA EL PUNTO DE NO PODER REPARARSE, PUEDE
 REEMPLAZARSE EN ESPECIE CON REVESTIMIENTO DE CIPR?S CON
 EL MISMO ANCHO Y PERFIL. SI M?S DEL 49% DEL
 REVESTIMIENTO EXISTENTE NECESITA SER REEMPLAZADO, SE
 REQUIERE QUE EL PROPIETARIO, EL CONTRATISTA O LA PARTE
 ASOCIADA SOLICITE UNA SOLICITUD DE CERTIFICADO DE
 APROPIACI?N (COA). LA INFORMACI?N DE REVESTIMIENTO
 PRESENTADA MUESTRA UN PERFIL DE BISEL. UN PERFIL DE
 BISEL ES APROPIADO PARA LA ADICI?N POSTERIOR QUE
 ACTUALMENTE NO TIENE REVESTIMIENTO. SI LA PORCI?N
 ORIGINAL DE LA ESTRUCTURA TIENE UN PERFIL DE BISEL.
  
 TRADUCCI?N AL ESPA?OL CORTES?A DE GOOGLE TRANSLATE
  
 PARA UNA RESPUESTA M?S R?PIDA, ENV?E UN CORREO
 ELECTR?NICO A AARON BORNGRABER, PLANIFICADOR DE
 PRESERVACI?N HIST?RICA A [email protected].
  
 AARON BORNGRABER
 PLANIFICADOR DE PRESERVACI?N HIST?RICA
 CIUDAD DE WEST PALM BEACH - SERVICIOS DE DESARROLLO
 T: 561-822-1428
  

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2020-01-24 Cont ID  
Sent By aborngra Date 2020-01-24 Time 10:43 Rev Time 0.00
Received By aborngra Date 2020-01-23 Time 08:15 Sent To PC
Notes
2020-01-24 10:43:17THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 1. A CERTIFICATE OF APPROPRIATENESS (COA) APPLICATION
 IS REQUIRED FOR DEMOLITION OF AN ACCESSORY STRUCTURE
 WITHIN A HISTORIC DISTRICT. ALL DEMOLITION REQUIRES A
 HISTORIC PRESERVATION BOARD REVIEW, THE NEXT UPCOMING
 DEADLINE IS FEBRUARY 19, 2020 FOR THE MARCH 24, 2020
 HEARING. PLEASE CONTACT STAFF TO OBTAIN A COPY OF THE
 COA APPLICATION. ALL MATERIALS REQUIRED UNDER
 ?DEMOLITION: ALL OTHER DEMOLITIONS? ARE REQUIRED ALONG
 WITH A $250.00 APPLICATION FEE.
 2. THE ROOF RAFTERS FOR THIS STRUCTURE MUST BE REPAIRED
 AND LEFT EXPOSED. REVISE ELEVATIONS.
 3. THE SIDING APPEARS TO BE CHANNEL BEVEL SIDING
 (PROFILE) ON THE ORIGINAL PORTION OF THE STRUCTURE. THE
 EXISTING SIDING SHALL BE REPAIRED, WHERE THE EXISTING
 SIDING HAS DETERIORATED TO THE POINT OF BEING UNABLE TO
 BE REPAIRED, IT MAY BE REPLACED IN KIND WITH CYPRESS
 SIDING WITH MATCHING WIDTH AND PROFILE. IF MORE THAN
 49% OF THE EXISTING SIDING NEEDS TO BE REPLACED, THE
 PROPERTY OWNER, CONTRACTOR, OR ASSOCIATED PARTY IS
 REQUIRED TO APPLY FOR A CERTIFICATE OF APPROPRIATENESS
 (COA) APPLICATION. ON YOUR NEXT SUBMITTAL PLEASE
 PROVIDE A COMMENT IN YOUR RESPONSE LETTER REGARDING THE
 PROFILE OF THE SIDING ON THE ORIGINAL STRUCTURE AND THE
 NEW SIDING THAT WILL BE INSTALLED ON THE REAR ADDITION
 THAT CURRENTLY HAS NO SIDING.
 4. THE PROPOSED WEST ELEVATION REAR WINDOW ON THE
 ORIGINAL STRUCTURE IS CURRENTLY MISSING AND HAS A
 DIFFERENT DIMENSION THAN THE PROPOSED OPENING. ALL NEW
 WINDOWS AND EXTERIOR DOORS WILL REQUIRE A PERMIT
 APPROVED AND ISSUED PRIOR TO INSTALLATION.
 5. INCONSISTENCIES STILL EXIST BETWEEN THE PROPOSED
 ELEVATIONS AND THE EXISTING CONDITIONS. PLEASE CLARIFY
 THESE ITEMS. IF THEY ARE NOT CLARIFIED IN THE NEXT
 SUBMITTAL, STAFF WILL PROPOSE CONDITIONS FOR
 COMPLIANCE.
  
  
 STAFF STRONGLY ENCOURAGES THAT THE PROPERTY OWNER APPLY
 FOR AN AD VALOREM TAX EXEMPTION. THE AD VALOREM
 APPLICATION WILL REQUIRE A STAFF REVIEW CERTIFICATE OF
 APPROPRIATENESS APPLICATION ALONG WITH A $250.00
 APPLICATION FEE. THE PROCESS HAS ADDITIONAL FEES TO
 COMPLETE THE POST-CONSTRUCTION PHASE OF THE
 APPLICATION. THE AD VALOREM TAX EXEMPTION PROGRAM IS A
 TAX EXEMPTION PROGRAM WHICH AUTHORIZES GRANTING AN
 EXEMPTION FROM THE INCREASES TO AD VALOREM TAXES FOR
 QUALIFIED IMPROVEMENTS TO PROPERTIES LISTED ON THE WEST
 PALM BEACH REGISTER OF HISTORIC PLACES. THIS EXEMPTION
 DOES NOT APPLY TO ASSESSED LAND VALUE, ONLY TO THE
 VALUE OF THE IMPROVEMENTS. THE PROGRAM PROVIDES AN
 ABATEMENT OF TAX INCREASES ON THE IMPROVEMENTS TO THE
 PROPERTY FOR A TEN (10) YEAR PERIOD ON THE CITY OF WEST
 PALM BEACH AND PALM BEACH COUNTY PORTION OF YOUR TAX
 BILL. THE ABATEMENT TIME PERIOD MAY BE TRANSFERRED TO
 FUTURE OWNERS. ALL WORK MUST BE PRE-APPROVED PRIOR TO
 THE START.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2019-10-24 Cont ID  
Sent By aborngra Date 2019-10-24 Time 11:42 Rev Time 0.00
Received By aborngra Date 2019-10-24 Time 11:41 Sent To PC
Notes
2019-10-24 11:42:53THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. CLARIFY. INCONSISTENCIES EXIST BETWEEN THE SCOPE OF
 WORK #3, PROPOSED ELEVATIONS, AND EXISTING CONDITIONS.
 2. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS.
 3. ESTIMATE WOOD SIDING NEEDING TO BE REPLACED. IF
 NUMBER EXCEEDS 49% OF THE WOOD SIDING SQUARE FOOTAGE, A
 CERTIFICATE OF APPROPRIATENESS APPLICATION MAY BE
 REQUIRED. PROVIDE EXISTING WOOD TYPE AND PROPOSED WOOD
 TYPE FOR WHERE SECTIONS NEED TO BE REPLACED.
 4. CLARIFY WINDOWS AND INTERIOR SPACE WITHIN THE FRONT
 ENCLOSED PORCH AREA. (EXAMPLE, WILL THE CURTAINS BE
 INSTALLED BEHIND THE WINDOWS OR WILL DRYWALL?)
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2021-02-19 Cont ID  
Sent By lmarchan Date 2021-02-19 Time 13:27 Rev Time 0.00
Received By lmarchan Date 2021-02-05 Time 16:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-07-22 Cont ID  
Sent By ppetty Date 2020-07-22 Time 12:28 Rev Time 0.00
Received By ppetty Date   Time   Sent To  
Notes
2020-07-22 08:09:51ROUTED TO R28

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-06-29 Cont ID  
Sent By shill Date 2020-05-28 Time 14:06 Rev Time 0.00
Received By shill Date 2020-05-20 Time 16:50 Sent To  
Notes
2020-05-20 16:50:40ROUTED TO ZONING IN BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-09 Cont ID  
Sent By dbattles Date 2020-03-09 Time 09:38 Rev Time 0.00
Received By dbattles Date 2020-02-18 Time 13:48 Sent To  
Notes
2020-02-24 15:20:19ROUTED FROM ZONING TO HISTORIC 2/24/20 EL
2020-02-19 13:48:54R28

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-13 Cont ID  
Sent By spalmer Date 2020-02-13 Time 18:30 Rev Time 0.00
Received By spalmer Date 2020-01-13 Time 13:39 Sent To  
Notes
2020-02-13 15:38:26ROUTED FROM ZONING TO PERMIT LIBRARIAN 2/13/20 EL
2020-01-14 13:39:49R21

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-10-31 Time   Rev Time 0.00
Received By lmarchan Date 2019-10-10 Time 14:55 Sent To  
Notes
2019-10-24 10:15:12ROUTED FROM ZONING TO HISTORIC 8/24/19 EL
2019-10-10 14:55:38R07

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2020-05-26 Cont ID  
Sent By pvalenti Date 2020-05-26 Time 08:43 Rev Time 0.00
Received By pvalenti Date 2020-05-26 Time 07:44 Sent To  
Notes
2020-05-26 08:44:52PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 MECHANICAL REVIEW APPROVED WITH PROVISO:
  
 AT TIME OF INSPECTION, PROVIDE AHRI SHEETS ON-SITE FOR
 INSPECTOR.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2020-02-27 Cont ID  
Sent By ccole Date 2020-02-27 Time 08:16 Rev Time 0.00
Received By ccole Date 2020-02-27 Time 07:52 Sent To  
Notes
2020-02-27 08:20:493RD REVIEW FBC-2017 MECHANICAL
 PERMIT #19100568
 2/27/2020
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS REMAINING FROM THE 1ST REVIEW ARE LISTED
 BELOW- PLEASE RESUBMIT CORRECTED PLANS AND THE
 REQUESTED CALCULATIONS.
  
 1) THE NEW ENERGY COMPLIANCE FORM R405-2017 LISTS THE
 NEW A C SYSTEM AS A 24,000 BTUH (2-TON) 14 SEER SYSTEM,
 HOWEVER THE EQUIPMENT SCHEDULED ON SHEET M-1 INDICATES
 A 30,000 BTUH (2.5 TON) 13 SEER SYSTEM. PLEAAE MATCH
 THE SYSTEMS ONE WAY OR THE OTHER.
  
 2) 3RD REQUEST: PROVIDE MANUAL J COOLING AND HEATING
 CALCULATIONS FOR THE NEW AC SYSTEM- SECTION R403.6.1
 FBC EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-01-28 Cont ID  
Sent By ccole Date 2020-01-28 Time 16:54 Rev Time 0.00
Received By ccole Date 2020-01-28 Time 16:27 Sent To  
Notes
2020-01-28 17:15:432ND REVIEW FBC-2017 MECHANICAL
 PERMIT #19100568
 1/28/2020
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS REMAINING FROM THE 1ST REVIEW ARE LISTED
 BELOW- PLEASE RESUBMIT CORRECTED PLANS AND THE
 REQUESTED CALCULATIONS.
  
 1) THE PREVIOUSLY NONCONDITIONED RESIDENCE NOW BEING
 CONDITIONED MUST BE BROUGHT INTO FULL COMPLIANCE WITH
 THE FBC-17 ENERGY CONSERVATION CODE- SECTION R503.2 FBC
 EC. SUBMIT AN ENERGY COMPLIANCE FORM IN ACCORDANCE WITH
 SECTION R101.5 FBC EC.
  
 2) SUBMIT ACCA MANUAL J COOLING AND HEATING
 CALCULATIONS FOR THE NEW AC SYSTEM- SECTION R403.6.1
 FBC EC.
  
 3) SHEET M-1: REQUIRED RETURN AIR FROM BEDROOMS NOT
 SHOWN ON THE PLAN- M1602.3 FBC RES.
  
 4) M-1: IT APPEARS THAT THE REQUIRED 30X30 ACCESS SPACE
 IN FRONT OF THE WATER HEATER WILL BE BLOCKED BY THE
 DRYER- SECTION M1305.1 FBC RES.
  
 5) M-1: INDICATE THE CLEAR OPENING DIMENSIONS OF THE
 AIR HANDLER ATTIC ACCESS PANEL, AND VERIFY IT IS SIZED
 LARGE ENOUGH TO ALLOW REMOVAL OF THE APPLIANCE- SECTION
 M1305.1.3 FBC RES.
  
 6) M-1: EXHAUST VENTILATION AT A RATE OF 100 CFMS
 INTERMITTENT OR 25 CFMS CONTINUOUS SHALL BE PROVIDED
 FOR THE KITCHEN- TABLE M1507.4 FBC RES. PLEASE SEE
 SECTION M1503.1 FOR RANGE HOOD REQUIREMENTS, AND
 M1503.4 FOR MAKEUP AIR.
  
 7) M-1: VERIFY COMPLIANCE WITH SECTION R403.3.6 FBC EC
 AIR-HANDLING UNITS IN ATTICS:
  
 AIR-HANDLING UNITS SHALL NOT BE INSTALLED IN THE ATTIC
 WHEN A HOME IS BROUGHT INTO CODE COMPLIANCE BY SECTION
 R402. AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS FOR
 COMPLIANCE BY SECTION R405 ONLY IF THE FOLLOWING
 CONDITIONS ARE MET:
  
 1.THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN
 6 FEET (1829 MM) OF AN ATTIC ACCESS.
  
 2.A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT DOWN
 THE UNIT WHEN THE CONDENSATION DRAIN IS NOT WORKING
 PROPERLY.
  
 3.THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO
 REPLACE THE AIR HANDLER.
  
 4.A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL
 INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS
 LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL
 CAPITALS, IN 16-POINT TYPE, WITH THE TITLE AND FIRST
 PARAGRAPH IN BOLD:
  
 NOTICE TO HOMEOWNER
 A PART OF YOUR AIR-CONDITIONING SYSTEM, THE AIR
 HANDLER, IS LOCATED IN THE ATTIC. FOR PROPER, EFFICIENT
 AND ECONOMIC OPERATION OF THE AIRCONDITIONING SYSTEM,
 YOU MUST ENSURE THAT REGULAR MAINTENANCE IS PERFORMED.
 YOUR AIR-CONDITIONING SYSTEM IS EQUIPPED WITH ONE OR
 BOTH OF THE FOLLOWING: (1) A DEVICE THAT WILL ALERT YOU
 WHEN THE CONDENSATION DRAIN IS NOT WORKING PROPERLY OR
 (2) A DEVICE THAT WILL SHUT DOWN THE SYSTEM WHEN THE
 CONDENSATION DRAIN IS NOT WORKING. TO LIMIT POTENTIAL
 DAMAGE TO YOUR HOME, AND TO AVOID DISRUPTION OF
 SERVICE, IT IS RECOMMENDED THAT YOU ENSURE PROPER
 WORKING ORDER OF THESE DEVICES BEFORE EACH SEASON OF
 PEAK OPERATION.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-10-29 Cont ID  
Sent By ccole Date 2019-10-29 Time 14:17 Rev Time 0.00
Received By ccole Date 2019-10-29 Time 14:17 Sent To  
Notes
2019-10-29 14:46:061ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19100568
 10/29/19
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE PREVIOUSLY NONCONDITIONED RESIDENCE NOW BEING
 CONDITIONED MUST BE BROUGHT INTO FULL COMPLIANCE WITH
 THE FBC-17 ENERGY CONSERVATION CODE- SECTION R503.2 FBC
 EC. SUBMIT AN ENERGY COMPLIANCE FORM IN ACCORDANCE WITH
 SECTION R101.5 FBC EC.
  
 2) SUBMIT ACCA MANUAL J COOLING AND HEATING
 CALCULATIONS FOR THE NEW AC SYSTEM- SECTION R403.6.1
 FBC EC.
  
 3) SHEET M-1: REQUIRED RETURN AIR FROM BEDROOMS NOT
 SHOWN ON THE PLAN- M1602.3 FBC RES.
  
 4) M-1: IT APPEARS THAT THE REQUIRED 30X30 ACCESS SPACE
 IN FRONT OF THE WATER HEATER WILL BE BLOCKED BY THE
 DRYER- SECTION M1305.1 FBC RES.
  
 5) M-1: INDICATE THE CLEAR OPENING DIMENSIONS OF THE
 AIR HANDLER ATTIC ACCESS PANEL, AND VERIFY IT IS SIZED
 LARGE ENOUGH TO ALLOW REMOVAL OF THE APPLIANCE- SECTION
 M1305.1.3 FBC RES.
  
 6) M-1: EXHAUST VENTILATION AT A RATE OF 100 CFMS
 INTERMITTENT OR 25 CFMS CONTINUOUS SHALL BE PROVIDED
 FOR THE KITCHEN- TABLE M1507.4 FBC RES. PLEASE SEE
 SECTION M1503.1 FOR RANGE HOOD REQUIREMENTS, AND
 M1503.4 FOR MAKEUP AIR.
  
 7) M-1: VERIFY COMPLIANCE WITH SECTION R403.3.6 FBC EC
 AIR-HANDLING UNITS IN ATTICS:
  
 AIR-HANDLING UNITS SHALL NOT BE INSTALLED IN THE ATTIC
 WHEN A HOME IS BROUGHT INTO CODE COMPLIANCE BY SECTION
 R402. AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS FOR
 COMPLIANCE BY SECTION R405 ONLY IF THE FOLLOWING
 CONDITIONS ARE MET:
  
 1.THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN
 6 FEET (1829 MM) OF AN ATTIC ACCESS.
  
 2.A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT DOWN
 THE UNIT WHEN THE CONDENSATION DRAIN IS NOT WORKING
 PROPERLY.
  
 3.THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO
 REPLACE THE AIR HANDLER.
  
 4.A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL
 INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS
 LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL
 CAPITALS, IN 16-POINT TYPE, WITH THE TITLE AND FIRST
 PARAGRAPH IN BOLD:
  
 NOTICE TO HOMEOWNER
 A PART OF YOUR AIR-CONDITIONING SYSTEM, THE AIR
 HANDLER, IS LOCATED IN THE ATTIC. FOR PROPER, EFFICIENT
 AND ECONOMIC OPERATION OF THE AIRCONDITIONING SYSTEM,
 YOU MUST ENSURE THAT REGULAR MAINTENANCE IS PERFORMED.
 YOUR AIR-CONDITIONING SYSTEM IS EQUIPPED WITH ONE OR
 BOTH OF THE FOLLOWING: (1) A DEVICE THAT WILL ALERT YOU
 WHEN THE CONDENSATION DRAIN IS NOT WORKING PROPERLY OR
 (2) A DEVICE THAT WILL SHUT DOWN THE SYSTEM WHEN THE
 CONDENSATION DRAIN IS NOT WORKING. TO LIMIT POTENTIAL
 DAMAGE TO YOUR HOME, AND TO AVOID DISRUPTION OF
 SERVICE, IT IS RECOMMENDED THAT YOU ENSURE PROPER
 WORKING ORDER OF THESE DEVICES BEFORE EACH SEASON OF
 PEAK OPERATION.
  
 8) M-1: PROVIDE A CONDENSATE DISPOSAL PLAN SHOWING THE
 PIPING RUN AND DISHARGE LOCATION, AND THE TYPE AND SIZE
 OF PIPE- SECTION M1411.3 FBC RES.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-10-22 Cont ID  
Sent By gjohnson Date 2019-10-22 Time 14:02 Rev Time 0.00
Received By gjohnson Date 2019-10-22 Time 08:14 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2020-01-28 Cont ID  
Sent By dbattles Date 2020-01-28 Time 15:01 Rev Time 0.00
Received By dbattles Date 2020-01-28 Time 15:00 Sent To  
Notes
2020-01-28 15:02:17NOA 16-0811.11 SHINGLE ROOF - OK
 NOA 18-0919.12 FLAT ROOF WITH ENHANCED NAILING ATTACHED
 - OK

Review Stop Z ZONING
Rev No 5 Status P Date 2021-02-19 Cont ID  
Sent By elevesqu Date 2021-02-19 Time 12:26 Rev Time 0.00
Received By elevesqu Date 2021-02-19 Time 12:26 Sent To  
Notes
2021-02-19 12:26:19LANDSCAPE PERMIT SUBMITTED - TO BE REVIEWED BY RAY
 CARANCI
  
 PROVISO:
 UNPERMITTED FENCE SHALL NEED TO BE REMOVED - ANY NEW
 FENCE REQUIRES SEPARATE PERMIT
  
  
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426

Review Stop Z ZONING
Rev No 4 Status P Date 2020-05-21 Cont ID  
Sent By elevesqu Date 2020-05-21 Time 15:36 Rev Time 0.00
Received By elevesqu Date 2020-05-21 Time 15:36 Sent To  
Notes
2020-05-21 15:36:13LANDSCAPE PERMIT SUBMITTED - TO BE REVIEWED BY RAY
 CARANCI
  
 PROVISO:
 UNPERMITTED FENCE SHALL NEED TO BE REMOVED - ANY NEW
 FENCE REQUIRES SEPARATE PERMIT
  
  
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426

Review Stop Z ZONING
Rev No 3 Status F Date 2020-02-24 Cont ID  
Sent By elevesqu Date 2020-02-24 Time 15:19 Rev Time 0.00
Received By elevesqu Date 2020-02-24 Time 15:19 Sent To  
Notes
2020-02-24 15:19:51REPEAT COMMENTS:
  
 PLEASE SUBMIT A LANDSCAPE PERMIT MEETING REQUIREMENTS
 PER SECTION 94-442
 MUST BE SUBMITTED PRIOR TO ZONING SIGN OFF
  
 CONTACT RAY CARANCI, LANDSCAPE PLANNER WITH ANY
 QUESTIONS 561 822 1462
  
  
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426

Review Stop Z ZONING
Rev No 2 Status F Date 2020-02-13 Cont ID  
Sent By elevesqu Date 2020-02-13 Time 15:38 Rev Time 0.00
Received By elevesqu Date 2020-02-13 Time 15:38 Sent To  
Notes
2020-02-13 15:38:04REPEAT COMMENTS:
  
 PLEASE SUBMIT A LANDSCAPE PERMIT MEETING REQUIREMENTS
 PER SECTION 94-442
 MUST BE SUBMITTED PRIOR TO ZONING SIGN OFF
  
 CONTACT RAY CARANCI, LANDSCAPE PLANNER WITH ANY
 QUESTIONS 561 822 1462
  
 UNPERMITTED FENCE SHALL NEED TO BE REMOVED - ANY NEW
 FENCE REQUIRES SEPARATE PERMIT
  
  
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426

Review Stop Z ZONING
Rev No 1 Status F Date 2019-10-24 Cont ID  
Sent By elevesqu Date 2019-10-24 Time 10:14 Rev Time 0.00
Received By elevesqu Date 2019-10-24 Time 10:14 Sent To  
Notes
2019-10-24 10:14:48PLEASE SUBMIT A LANDSCAPE PERMIT MEETING REQUIREMENTS
 PER SECTION 94-442
 MUST BE SUBMITTED PRIOR TO ZONING SIGN OFF
  
 CONTACT RAY CARANCI, LANDSCAPE PLANNER WITH ANY
 QUESTIONS 561 822 1462
  
 UNPERMITTED FENCE SHALL NEED TO BE REMOVED - ANY NEW
 FENCE REQUIRES SEPARATE PERMIT
  
 PLEASE ADDRESS EXISTING GARAGE - WILL THIS BE REMOVED?
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426