Plan Review Details - Permit 19100568
| Plan Review Stops For Permit 19100568 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-05-26 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-05-26 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-05-26 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-03-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-03-09 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-03-09 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-01-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-01-28 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-01-28 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-10-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-10-28 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-10-25 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2019-10-28 08:08:08 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19100568 | | | REVIEWED: OCTOBER 25, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | FBC[R] = FBC RESIDENTIAL | | | | | | 1. 501 FBC[EXISTING] LEVEL OF ALTERATION FOR WORK BEING | | | PERFORMED. | | | - PLEASE CHANGE TO LEVEL 3 ALTERATION. SINCE THE WORK | | | AREA IS OVER 50% OF THE BUILDING AREA. | | | | | | 2. 320.1 FBC[R] ALL NEW SINGLE-FAMILY HOUSES, DUPLEXES, | | | TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL PROVIDE AT | | | LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE | | | PRIVACY, WHERE BATHROOMS ARE PROVIDED ON HABITABLE | | | GRADE LEVELS, WITH A DOOR THAT HAS A 29-INCH CLEAR | | | OPENING. HOWEVER, IF ONLY A TOILET ROOM IS PROVIDED AT | | | GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR | | | OPENING OF NOT LESS THAN 29 INCHES. | | | - WHAT IS THE WIDTH OF CLEAR OPENING AT BATHROOM DOORS? | | | WILL ONE OF THEM PROVIDE MINIMUM OF 29 INCHES? | | | | | | 3. 311.2 FBC[R] NOT LESS THAN ONE EGRESS DOOR SHALL BE | | | PROVIDED FOR EACH DWELLING UNIT. THE EGRESS DOOR SHALL | | | BE SIDE-HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT | | | LESS THAN 32 INCHES WHERE MEASURED BETWEEN THE FACE OF | | | THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES | | | (1.57 RAD). THE CLEAR HEIGHT OF THE DOOR OPENING SHALL | | | BE NOT LESS THAN 78 INCHES IN HEIGHT MEASURED FROM THE | | | TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP. OTHER | | | DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE | | | MINIMUM DIMENSIONS. EGRESS DOORS SHALL BE READILY | | | OPENABLE FROM INSIDE THE DWELLING WITHOUT THE USE OF A | | | KEY OR SPECIAL KNOWLEDGE OR EFFORT. | | | | | | 4. 311.3 FBC[R] FLOORS AND LANDINGS AT EXTERIOR DOORS. | | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | | EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT | | | LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A | | | DIMENSION OF NOT LESS THAN 36 INCHES (914 MM) MEASURED | | | IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR | | | LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS | | | HORIZONTAL (2 PERCENT). | | | - PROVIDE LANDING AT EXTERIOR SIDE OF DOOR IF GREATER | | | THAN 2 RISERS PROVIDED. | | | | | | 5. 408.1 FBC[R] PROVIDE VENTING CALCULATIONS FOR UNDER | | | FLOOR SPACE, OR FOLLOW REQUIREMENTS FOR UNVENTED. | | | - IS THE UNDER FLOOR SPACE VENTED OR UNVENTED? IF | | | UNVENTED SEE SECTION R408.3 UNVENTED CRAWL SPACE. | | | | | | 6. 408.4 FBC[R] PROVIDE ACCESS TO THE UNDER FLOOR SPACE | | | 18X24 MINIMUM. | | | - THIS IS REQUIRED FOR VENTED OR UNVENTED. | | | | | | 7. 806 FBC[R] SUPPLY VENTING CALCULATIONS FOR THE ATTIC | | | AND HOW THE AREA OF VENTING WILL BE ACHIEVED, OR FOLLOW | | | R806.5 FOR UNVENTED. | | | - IS THE ATTIC TO BE VENTED OR UNVENTED? | | | | | | 8. 806.5 FBC[R] UNVENTED ATTIC AND UNVENTED ENCLOSED | | | RAFTER ASSEMBLIES. 5.1.2. WHERE AIR-PERMEABLE | | | INSULATION IS PROVIDED INSIDE THE BUILDING THERMAL | | | ENVELOPE, IT SHALL BE INSTALLED IN ACCORDANCE WITH | | | SECTION 5.1.1. IN ADDITION TO THE AIR-PERMEABLE | | | INSULATION INSTALLED DIRECTLY BELOW THE STRUCTURAL | | | SHEATHING, RIGID BOARD OR SHEET INSULATION SHALL BE | | | INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHEATHING | | | IN ACCORDANCE WITH THE R-VALUES IN TABLE R806.5 FOR | | | CONDENSATION CONTROL. | | | - IF UNVENTED PLEASE REVIEW THIS SECTION FOR AIR | | | PERMEABLE INSULATION AT ROOF DECK. | | | | | | 9. [RAS 117]PROVIDE ENGINEERING FOR ENHANCED NAILING AS | | | STATED IN PRODUCT APPROVAL UNDER GENERAL LIMITATIONS | | | #7. | | | - THE PRODUCT APPROVAL FOR FLAT ROOFING REQUIRES | | | ENGINEERING FOR ENHANCED NAILING OF ZONES 2 AND 3. | | | ALSO, SELECT FASTENING OPTION TO BE USED FROM SHEET 51 | | | OR 52. | | | | | | NOTES: | | | | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS. | | | FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE | | | REQUIRED. | | | | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2021-02-08 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-02-08 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-02-08 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2020-07-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2020-07-22 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2020-07-22 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2020-07-22 11:42:44 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED | | | 2. CORRECTED | | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 (NOT PROVIDED.)(3RD REVIEW: STILL NOT | | | PROVIDED.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. CORRECTED | | | 12. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2020-05-27 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2020-05-27 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2020-05-27 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2020-05-27 08:02:39 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED | | | 2. CORRECTED | | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 (NOT PROVIDED.)(3RD REVIEW: STILL NOT | | | PROVIDED.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. RISER DIAGRAM SHOWS A FEED FROM THE METER TO THE | | | INTERIOR PANEL WHICH IS LOCATED IN THE HALLWAY. | | | CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR | | | DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE | | | IN THIS FASHION. PROVIDE EITHER A MAIN ON THE OUTSIDE | | | OF THE HOME, OR INSTALL THE CONDUCTORS UNDER THE SLAB. | | | IF THERE IS A DISCONNECT AT THE METER, THE CONDUIT TO | | | THE INTERIOR PANEL SHALL INCLUDE AN EQUIPMENT GROUNDING | | | CONDUCTOR. PROVIDE CORRECTIONS. NEC 230.70, 250.6, | | | 250.118; FBC RE E3601.6 (NOT CORRECTED.)(3RD REVIEW: | | | STILL NOT CORRECTED.) | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. CORRECTED | | | 12. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2020-03-06 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-03-06 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-03-06 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2020-03-06 15:07:59 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. AFCI PROTECTION DETAILED IN NEW ELECTRIC NOTE IS NOT | | | CODE COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY | | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | | PROTECTED. THIS INCLUDES LIGHTING AND POWER OUTLETS AND | | | RECEPTACLES. SOME AREAS REQUIRE BOTH AFCI AND GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12; FBC | | | RE E3902; FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS | | | APPLICABLE. (NOT CORRECTED.)(3RD REVIEW: NOTE IS | | | CORRECTED IN ONE LOCATION, BUT NOT THE OTHER. CORRECT | | | DISCREPANCY.) | | | 2. UNDER NEW ELECTRIC NOTE AND NOTE 14, THESE NOTES | | | STATE THAT RECEPTACLES SHALL BE TAMPER RESISTANT PER | | | NEC 406.11. THIS CODE SECTION DOES NOT APPLY TO TAMPER | | | RESISTANT RECEPTACLES. PROVIDE CORRECTION. NEC 406.12; | | | FBC RE E4002.14 (NOT CORRECTED.)(3RD REVIEW: NOTE IS | | | CORRECTED IN ONE LOCATION, BUT NOT THE OTHER. CORRECT | | | DISCREPANCY.) | | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 (NOT PROVIDED.)(3RD REVIEW: STILL NOT | | | PROVIDED.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. RISER DIAGRAM SHOWS A FEED FROM THE METER TO THE | | | INTERIOR PANEL WHICH IS LOCATED IN THE HALLWAY. | | | CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR | | | DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE | | | IN THIS FASHION. PROVIDE EITHER A MAIN ON THE OUTSIDE | | | OF THE HOME, OR INSTALL THE CONDUCTORS UNDER THE SLAB. | | | IF THERE IS A DISCONNECT AT THE METER, THE CONDUIT TO | | | THE INTERIOR PANEL SHALL INCLUDE AN EQUIPMENT GROUNDING | | | CONDUCTOR. PROVIDE CORRECTIONS. NEC 230.70, 250.6, | | | 250.118; FBC RE E3601.6 (NOT CORRECTED.)(3RD REVIEW: | | | STILL NOT CORRECTED.) | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. LOAD CALCULATION PROVIDED IS NOT CODE COMPLIANT. | | | NEC 220; FBC RE E3602.2 (NOT PROVIDED. THERE ARE | | | SEVERAL PROBLEMS WITH CALCULATION. ALSO, WHAT IS THE | | | SIZE OF THE TANKLESS WATER HEATER BEING USED. PANEL | | | SCHEDULE SAYS IT IS 3500 VA, BUT THIS IS NOT ONE OF THE | | | SIZES SHOWN ON CUT SHEET PROVIDED.)(3RD REVIEW: STILL | | | NOT CORRECTED. CALCULATION SHOULD BE OF THE TYPE FOR A | | | DWELLING UNIT, AS SPEICIFED IN FBC RE 3602.2) | | | 12. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-01-31 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-01-31 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-01-31 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2020-01-31 13:44:09 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. AFCI PROTECTION DETAILED IN NEW ELECTRIC NOTE IS NOT | | | CODE COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY | | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | | PROTECTED. THIS INCLUDES LIGHTING AND POWER OUTLETS AND | | | RECEPTACLES. SOME AREAS REQUIRE BOTH AFCI AND GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12; FBC | | | RE E3902; FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS | | | APPLICABLE. (NOT CORRECTED.) | | | 2. UNDER NEW ELECTRIC NOTE AND NOTE 14, THESE NOTES | | | STATE THAT RECEPTACLES SHALL BE TAMPER RESISTANT PER | | | NEC 406.11. THIS CODE SECTION DOES NOT APPLY TO TAMPER | | | RESISTANT RECEPTACLES. PROVIDE CORRECTION. NEC 406.12; | | | FBC RE E4002.14 (NOT CORRECTED.) | | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 (NOT PROVIDED.) | | | 4. CORRECTED. | | | 5. RISER DIAGRAM CONFLICTS WITH PANEL SCHEDULE. IS | | | PANEL A A PANEL WITH A MAIN BREAKER, OR IS IT MAIN LUG | | | ONLY? PROVIDE CLARIFICATIONS AND CORRECTIONS. NEC | | | 215.5; WPB FBC 107.2.1 (NOT CORRECTED.) | | | 6. RISER DIAGRAM SHOWS A FEED FROM THE METER TO THE | | | INTERIOR PANEL WHICH IS LOCATED IN THE HALLWAY. | | | CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR | | | DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE | | | IN THIS FASHION. PROVIDE EITHER A MAIN ON THE OUTSIDE | | | OF THE HOME, OR INSTALL THE CONDUCTORS UNDER THE SLAB. | | | IF THERE IS A DISCONNECT AT THE METER, THE CONDUIT TO | | | THE INTERIOR PANEL SHALL INCLUDE AN EQUIPMENT GROUNDING | | | CONDUCTOR. PROVIDE CORRECTIONS. NEC 230.70, 250.6, | | | 250.118; FBC RE E3601.6 (NOT CORRECTED.) | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 (NOT PROVIDED.) | | | 10. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 (NOT PROVIDED.) | | | 11. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. LOAD CALCULATION PROVIDED IS NOT CODE COMPLIANT. | | | NEC 220; FBC RE E3602.2 (NOT PROVIDED. THERE ARE | | | SEVERAL PROBLEMS WITH CALCULATION. ALSO, WHAT IS THE | | | SIZE OF THE TANKLESS WATER HEATER BEING USED. PANEL | | | SCHEDULE SAYS IT IS 3500 VA, BUT THIS IS NOT ONE OF THE | | | SIZES SHOWN ON CUT SHEET PROVIDED.) | | | 12. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-10-31 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-10-31 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-10-31 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2019-10-31 15:13:19 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. AFCI PROTECTION DETAILED IN NEW ELECTRIC NOTE IS NOT | | | CODE COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY | | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | | PROTECTED. THIS INCLUDES LIGHTING AND POWER OUTLETS AND | | | RECEPTACLES. SOME AREAS REQUIRE BOTH AFCI AND GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12; FBC | | | RE E3902; FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS | | | APPLICABLE. | | | 2. UNDER NEW ELECTRIC NOTE AND NOTE 14, THESE NOTES | | | STATE THAT RECEPTACLES SHALL BE TAMPER RESISTANT PER | | | NEC 406.11. THIS CODE SECTION DOES NOT APPLY TO TAMPER | | | RESISTANT RECEPTACLES. PROVIDE CORRECTION. NEC 406.12; | | | FBC RE E4002.14 | | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 | | | 4. PROVIDE AIC RATING OF ANY SERVICE DISCONNECTS AND | | | PANELS. NEC 110.3, 110.9; FBC RE E3606.3 | | | 5. RISER DIAGRAM CONFLICTS WITH PANEL SCHEDULE. IS | | | PANEL A A PANEL WITH A MAIN BREAKER, OR IS IT MAIN LUG | | | ONLY? PROVIDE CLARIFICATIONS AND CORRECTIONS. NEC | | | 215.5; WPB FBC 107.2.1 | | | 6. RISER DIAGRAM SHOWS A FEED FROM THE METER TO THE | | | INTERIOR PANEL WHICH IS LOCATED IN THE HALLWAY. | | | CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR | | | DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE | | | IN THIS FASHION. PROVIDE EITHER A MAIN ON THE OUTSIDE | | | OF THE HOME, OR INSTALL THE CONDUCTORS UNDER THE SLAB. | | | IF THERE IS A DISCONNECT AT THE METER, THE CONDUIT TO | | | THE INTERIOR PANEL SHALL INCLUDE AN EQUIPMENT GROUNDING | | | CONDUCTOR. PROVIDE CORRECTIONS. NEC 230.70, 250.6, | | | 250.118; FBC RE E3601.6 | | | 7. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM | | | BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET | | | FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE | | | R314.3(4), NFPA 72:29.8.3.4 | | | 8. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | 9. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 10. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 11. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. LOAD CALCULATION PROVIDED IS NOT CODE COMPLIANT. | | | NEC 220; FBC RE E3602.2 | | | 12. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
4 |
Status |
P |
Date |
2020-05-22 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-05-22 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-05-22 |
Time |
10:40 |
Sent To |
B |
|
| Notes |
| 2020-05-22 10:41:08 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | AMENDMENT(S) AND CONDITION(S): | | | | | | THE FOLLOWING ITEMS ARE NOT APPROVED WITH THIS PERMIT: | | | A. A SEPARATE DEMOLITION PERMIT IS REQUIRED WITH | | | INTERIOR AND EXTERIOR PHOTOS SUBMITTED FOR DEMOLITION | | | OF THE ACCESSORY STRUCTURE. ADDITIONAL REQUIREMENTS MAY | | | BE NECESSARY. | | | B. A SEPARATE FENCE PERMIT IS REQUIRED. | | | | | | THE FOLLOWING CONDITION(S) OF APPROVAL TO THE PERMIT: | | | 1. THE NEW WINDOW TO BE INSTALLED SHALL HAVE CLEAR | | | GLASS (NO LOW-E COATING, TINTED GLASS, OR PRIVACY | | | GLASS) AND MATCH THE INSET/DEPTH/LOCATION OF THE OTHER | | | ORIGINAL WINDOWS WITH THIS WINDOW FRAME OPENING. IF THE | | | EXISTING WINDOWS AND EXTERIOR DOORS CANNOT BE REPAIRED | | | AND NEED TO BE REPLACED. A SEPARATE PERMIT WILL BE | | | REQUIRED TO BE APPROVED AND ISSUED PRIOR TO | | | INSTALLATION. | | | 2. THE SIDING APPEARS TO BE CHANNEL BEVEL SIDING | | | (PROFILE) ON THE ORIGINAL PORTION OF THE STRUCTURE. THE | | | EXISTING SIDING SHALL BE REPAIRED, WHERE THE EXISTING | | | SIDING HAS DETERIORATED TO THE POINT OF BEING UNABLE TO | | | BE REPAIRED, IT MAY BE REPLACED IN KIND WITH CYPRESS | | | SIDING WITH MATCHING WIDTH AND PROFILE. IF MORE THAN | | | 49% OF THE EXISTING SIDING NEEDS TO BE REPLACED, THE | | | PROPERTY OWNER, CONTRACTOR, OR ASSOCIATED PARTY IS | | | REQUIRED TO APPLY FOR A CERTIFICATE OF APPROPRIATENESS | | | (COA) APPLICATION. THE SUBMITTED SIDING INFORMATION | | | SHOWS A BEVEL PROFILE. A BEVEL PROFILE IS APPROPRIATE | | | FOR THE REAR ADDITION THAT CURRENTLY DOES NOT HAVE | | | SIDING ON IT. IF THE ORIGINAL PORTION OF THE STRUCTURE | | | HAS A BEVEL PROFILE. | | | | | | SPANISH TRANSLATION COURTESY OF GOOGLE TRANSLATE | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | | | | EL PERMISO HA SIDO APROBADO CON LAS SIGUIENTES | | | ENMIENDAS Y CONDICIONES: | | | | | | LOS SIGUIENTES ART?CULOS NO EST?N APROBADOS CON ESTE | | | PERMISO: | | | A. SE REQUIERE UN PERMISO DE DEMOLICI?N POR SEPARADO | | | CON FOTOS INTERIORES Y EXTERIORES ENVIADAS PARA LA | | | DEMOLICI?N DE LA ESTRUCTURA ACCESORIA. PUEDEN SER | | | NECESARIOS REQUISITOS ADICIONALES. | | | SI. SE REQUIERE UN PERMISO DE VALLA SEPARADO. | | | | | | LAS SIGUIENTES CONDICIONES DE APROBACI?N DEL PERMISO: | | | 1. LA NUEVA VENTANA QUE SE INSTALAR? DEBE TENER VIDRIO | | | TRANSPARENTE (SIN RECUBRIMIENTO DE BAJA EMISIVIDAD, | | | VIDRIO TINTADO O VIDRIO DE PRIVACIDAD) Y DEBE COINCIDIR | | | CON LA INSERCI?N / PROFUNDIDAD / UBICACI?N DE LAS OTRAS | | | VENTANAS ORIGINALES CON ESTA ABERTURA DEL MARCO DE LA | | | VENTANA. SI LAS VENTANAS Y PUERTAS EXTERIORES | | | EXISTENTES NO PUEDEN REPARARSE Y DEBEN REEMPLAZARSE. SE | | | REQUERIR? UN PERMISO POR SEPARADO PARA SER APROBADO Y | | | EMITIDO ANTES DE LA INSTALACI?N. | | | 2. EL REVESTIMIENTO PARECE SER UN REVESTIMIENTO DE | | | BISEL DE CANAL (PERFIL) EN LA PORCI?N ORIGINAL DE LA | | | ESTRUCTURA. EL REVESTIMIENTO EXISTENTE DEBE REPARARSE, | | | DONDE EL REVESTIMIENTO EXISTENTE SE HA DETERIORADO | | | HASTA EL PUNTO DE NO PODER REPARARSE, PUEDE | | | REEMPLAZARSE EN ESPECIE CON REVESTIMIENTO DE CIPR?S CON | | | EL MISMO ANCHO Y PERFIL. SI M?S DEL 49% DEL | | | REVESTIMIENTO EXISTENTE NECESITA SER REEMPLAZADO, SE | | | REQUIERE QUE EL PROPIETARIO, EL CONTRATISTA O LA PARTE | | | ASOCIADA SOLICITE UNA SOLICITUD DE CERTIFICADO DE | | | APROPIACI?N (COA). LA INFORMACI?N DE REVESTIMIENTO | | | PRESENTADA MUESTRA UN PERFIL DE BISEL. UN PERFIL DE | | | BISEL ES APROPIADO PARA LA ADICI?N POSTERIOR QUE | | | ACTUALMENTE NO TIENE REVESTIMIENTO. SI LA PORCI?N | | | ORIGINAL DE LA ESTRUCTURA TIENE UN PERFIL DE BISEL. | | | | | | TRADUCCI?N AL ESPA?OL CORTES?A DE GOOGLE TRANSLATE | | | | | | PARA UNA RESPUESTA M?S R?PIDA, ENV?E UN CORREO | | | ELECTR?NICO A AARON BORNGRABER, PLANIFICADOR DE | | | PRESERVACI?N HIST?RICA A [email protected]. | | | | | | AARON BORNGRABER | | | PLANIFICADOR DE PRESERVACI?N HIST?RICA | | | CIUDAD DE WEST PALM BEACH - SERVICIOS DE DESARROLLO | | | T: 561-822-1428 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-02-26 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-02-26 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-02-25 |
Time |
10:02 |
Sent To |
PC |
|
| Notes |
| 2020-02-26 11:11:10 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | AMENDMENT(S) AND CONDITION(S): | | | | | | THE FOLLOWING ITEMS ARE NOT APPROVED WITH THIS PERMIT: | | | A. A SEPARATE DEMOLITION PERMIT IS REQUIRED WITH | | | INTERIOR AND EXTERIOR PHOTOS SUBMITTED FOR DEMOLITION | | | OF THE ACCESSORY STRUCTURE. ADDITIONAL REQUIREMENTS MAY | | | BE NECESSARY. | | | B. A SEPARATE FENCE PERMIT IS REQUIRED. | | | | | | THE FOLLOWING CONDITION(S) OF APPROVAL TO THE PERMIT: | | | 1. THE NEW WINDOW TO BE INSTALLED SHALL HAVE CLEAR | | | GLASS (NO LOW-E COATING, TINTED GLASS, OR PRIVACY | | | GLASS) AND MATCH THE INSET/DEPTH/LOCATION OF THE OTHER | | | ORIGINAL WINDOWS WITH THIS WINDOW FRAME OPENING. IF THE | | | EXISTING WINDOWS AND EXTERIOR DOORS CANNOT BE REPAIRED | | | AND NEED TO BE REPLACED. A SEPARATE PERMIT WILL BE | | | REQUIRED TO BE APPROVED AND ISSUED PRIOR TO | | | INSTALLATION. | | | 2. THE SIDING APPEARS TO BE CHANNEL BEVEL SIDING | | | (PROFILE) ON THE ORIGINAL PORTION OF THE STRUCTURE. THE | | | EXISTING SIDING SHALL BE REPAIRED, WHERE THE EXISTING | | | SIDING HAS DETERIORATED TO THE POINT OF BEING UNABLE TO | | | BE REPAIRED, IT MAY BE REPLACED IN KIND WITH CYPRESS | | | SIDING WITH MATCHING WIDTH AND PROFILE. IF MORE THAN | | | 49% OF THE EXISTING SIDING NEEDS TO BE REPLACED, THE | | | PROPERTY OWNER, CONTRACTOR, OR ASSOCIATED PARTY IS | | | REQUIRED TO APPLY FOR A CERTIFICATE OF APPROPRIATENESS | | | (COA) APPLICATION. THE SUBMITTED SIDING INFORMATION | | | SHOWS A BEVEL PROFILE. A BEVEL PROFILE IS APPROPRIATE | | | FOR THE REAR ADDITION THAT CURRENTLY DOES NOT HAVE | | | SIDING ON IT. IF THE ORIGINAL PORTION OF THE STRUCTURE | | | HAS A BEVEL PROFILE. | | | | | | SPANISH TRANSLATION COURTESY OF GOOGLE TRANSLATE | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | | | | EL PERMISO HA SIDO APROBADO CON LAS SIGUIENTES | | | ENMIENDAS Y CONDICIONES: | | | | | | LOS SIGUIENTES ART?CULOS NO EST?N APROBADOS CON ESTE | | | PERMISO: | | | A. SE REQUIERE UN PERMISO DE DEMOLICI?N POR SEPARADO | | | CON FOTOS INTERIORES Y EXTERIORES ENVIADAS PARA LA | | | DEMOLICI?N DE LA ESTRUCTURA ACCESORIA. PUEDEN SER | | | NECESARIOS REQUISITOS ADICIONALES. | | | SI. SE REQUIERE UN PERMISO DE VALLA SEPARADO. | | | | | | LAS SIGUIENTES CONDICIONES DE APROBACI?N DEL PERMISO: | | | 1. LA NUEVA VENTANA QUE SE INSTALAR? DEBE TENER VIDRIO | | | TRANSPARENTE (SIN RECUBRIMIENTO DE BAJA EMISIVIDAD, | | | VIDRIO TINTADO O VIDRIO DE PRIVACIDAD) Y DEBE COINCIDIR | | | CON LA INSERCI?N / PROFUNDIDAD / UBICACI?N DE LAS OTRAS | | | VENTANAS ORIGINALES CON ESTA ABERTURA DEL MARCO DE LA | | | VENTANA. SI LAS VENTANAS Y PUERTAS EXTERIORES | | | EXISTENTES NO PUEDEN REPARARSE Y DEBEN REEMPLAZARSE. SE | | | REQUERIR? UN PERMISO POR SEPARADO PARA SER APROBADO Y | | | EMITIDO ANTES DE LA INSTALACI?N. | | | 2. EL REVESTIMIENTO PARECE SER UN REVESTIMIENTO DE | | | BISEL DE CANAL (PERFIL) EN LA PORCI?N ORIGINAL DE LA | | | ESTRUCTURA. EL REVESTIMIENTO EXISTENTE DEBE REPARARSE, | | | DONDE EL REVESTIMIENTO EXISTENTE SE HA DETERIORADO | | | HASTA EL PUNTO DE NO PODER REPARARSE, PUEDE | | | REEMPLAZARSE EN ESPECIE CON REVESTIMIENTO DE CIPR?S CON | | | EL MISMO ANCHO Y PERFIL. SI M?S DEL 49% DEL | | | REVESTIMIENTO EXISTENTE NECESITA SER REEMPLAZADO, SE | | | REQUIERE QUE EL PROPIETARIO, EL CONTRATISTA O LA PARTE | | | ASOCIADA SOLICITE UNA SOLICITUD DE CERTIFICADO DE | | | APROPIACI?N (COA). LA INFORMACI?N DE REVESTIMIENTO | | | PRESENTADA MUESTRA UN PERFIL DE BISEL. UN PERFIL DE | | | BISEL ES APROPIADO PARA LA ADICI?N POSTERIOR QUE | | | ACTUALMENTE NO TIENE REVESTIMIENTO. SI LA PORCI?N | | | ORIGINAL DE LA ESTRUCTURA TIENE UN PERFIL DE BISEL. | | | | | | TRADUCCI?N AL ESPA?OL CORTES?A DE GOOGLE TRANSLATE | | | | | | PARA UNA RESPUESTA M?S R?PIDA, ENV?E UN CORREO | | | ELECTR?NICO A AARON BORNGRABER, PLANIFICADOR DE | | | PRESERVACI?N HIST?RICA A [email protected]. | | | | | | AARON BORNGRABER | | | PLANIFICADOR DE PRESERVACI?N HIST?RICA | | | CIUDAD DE WEST PALM BEACH - SERVICIOS DE DESARROLLO | | | T: 561-822-1428 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-01-24 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-01-24 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-01-23 |
Time |
08:15 |
Sent To |
PC |
|
| Notes |
| 2020-01-24 10:43:17 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. A CERTIFICATE OF APPROPRIATENESS (COA) APPLICATION | | | IS REQUIRED FOR DEMOLITION OF AN ACCESSORY STRUCTURE | | | WITHIN A HISTORIC DISTRICT. ALL DEMOLITION REQUIRES A | | | HISTORIC PRESERVATION BOARD REVIEW, THE NEXT UPCOMING | | | DEADLINE IS FEBRUARY 19, 2020 FOR THE MARCH 24, 2020 | | | HEARING. PLEASE CONTACT STAFF TO OBTAIN A COPY OF THE | | | COA APPLICATION. ALL MATERIALS REQUIRED UNDER | | | ?DEMOLITION: ALL OTHER DEMOLITIONS? ARE REQUIRED ALONG | | | WITH A $250.00 APPLICATION FEE. | | | 2. THE ROOF RAFTERS FOR THIS STRUCTURE MUST BE REPAIRED | | | AND LEFT EXPOSED. REVISE ELEVATIONS. | | | 3. THE SIDING APPEARS TO BE CHANNEL BEVEL SIDING | | | (PROFILE) ON THE ORIGINAL PORTION OF THE STRUCTURE. THE | | | EXISTING SIDING SHALL BE REPAIRED, WHERE THE EXISTING | | | SIDING HAS DETERIORATED TO THE POINT OF BEING UNABLE TO | | | BE REPAIRED, IT MAY BE REPLACED IN KIND WITH CYPRESS | | | SIDING WITH MATCHING WIDTH AND PROFILE. IF MORE THAN | | | 49% OF THE EXISTING SIDING NEEDS TO BE REPLACED, THE | | | PROPERTY OWNER, CONTRACTOR, OR ASSOCIATED PARTY IS | | | REQUIRED TO APPLY FOR A CERTIFICATE OF APPROPRIATENESS | | | (COA) APPLICATION. ON YOUR NEXT SUBMITTAL PLEASE | | | PROVIDE A COMMENT IN YOUR RESPONSE LETTER REGARDING THE | | | PROFILE OF THE SIDING ON THE ORIGINAL STRUCTURE AND THE | | | NEW SIDING THAT WILL BE INSTALLED ON THE REAR ADDITION | | | THAT CURRENTLY HAS NO SIDING. | | | 4. THE PROPOSED WEST ELEVATION REAR WINDOW ON THE | | | ORIGINAL STRUCTURE IS CURRENTLY MISSING AND HAS A | | | DIFFERENT DIMENSION THAN THE PROPOSED OPENING. ALL NEW | | | WINDOWS AND EXTERIOR DOORS WILL REQUIRE A PERMIT | | | APPROVED AND ISSUED PRIOR TO INSTALLATION. | | | 5. INCONSISTENCIES STILL EXIST BETWEEN THE PROPOSED | | | ELEVATIONS AND THE EXISTING CONDITIONS. PLEASE CLARIFY | | | THESE ITEMS. IF THEY ARE NOT CLARIFIED IN THE NEXT | | | SUBMITTAL, STAFF WILL PROPOSE CONDITIONS FOR | | | COMPLIANCE. | | | | | | | | | STAFF STRONGLY ENCOURAGES THAT THE PROPERTY OWNER APPLY | | | FOR AN AD VALOREM TAX EXEMPTION. THE AD VALOREM | | | APPLICATION WILL REQUIRE A STAFF REVIEW CERTIFICATE OF | | | APPROPRIATENESS APPLICATION ALONG WITH A $250.00 | | | APPLICATION FEE. THE PROCESS HAS ADDITIONAL FEES TO | | | COMPLETE THE POST-CONSTRUCTION PHASE OF THE | | | APPLICATION. THE AD VALOREM TAX EXEMPTION PROGRAM IS A | | | TAX EXEMPTION PROGRAM WHICH AUTHORIZES GRANTING AN | | | EXEMPTION FROM THE INCREASES TO AD VALOREM TAXES FOR | | | QUALIFIED IMPROVEMENTS TO PROPERTIES LISTED ON THE WEST | | | PALM BEACH REGISTER OF HISTORIC PLACES. THIS EXEMPTION | | | DOES NOT APPLY TO ASSESSED LAND VALUE, ONLY TO THE | | | VALUE OF THE IMPROVEMENTS. THE PROGRAM PROVIDES AN | | | ABATEMENT OF TAX INCREASES ON THE IMPROVEMENTS TO THE | | | PROPERTY FOR A TEN (10) YEAR PERIOD ON THE CITY OF WEST | | | PALM BEACH AND PALM BEACH COUNTY PORTION OF YOUR TAX | | | BILL. THE ABATEMENT TIME PERIOD MAY BE TRANSFERRED TO | | | FUTURE OWNERS. ALL WORK MUST BE PRE-APPROVED PRIOR TO | | | THE START. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-10-24 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-10-24 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-10-24 |
Time |
11:41 |
Sent To |
PC |
|
| Notes |
| 2019-10-24 11:42:53 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | 1. CLARIFY. INCONSISTENCIES EXIST BETWEEN THE SCOPE OF | | | WORK #3, PROPOSED ELEVATIONS, AND EXISTING CONDITIONS. | | | 2. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. | | | 3. ESTIMATE WOOD SIDING NEEDING TO BE REPLACED. IF | | | NUMBER EXCEEDS 49% OF THE WOOD SIDING SQUARE FOOTAGE, A | | | CERTIFICATE OF APPROPRIATENESS APPLICATION MAY BE | | | REQUIRED. PROVIDE EXISTING WOOD TYPE AND PROPOSED WOOD | | | TYPE FOR WHERE SECTIONS NEED TO BE REPLACED. | | | 4. CLARIFY WINDOWS AND INTERIOR SPACE WITHIN THE FRONT | | | ENCLOSED PORCH AREA. (EXAMPLE, WILL THE CURTAINS BE | | | INSTALLED BEHIND THE WINDOWS OR WILL DRYWALL?) | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2021-02-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-02-19 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-02-05 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2020-07-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2020-07-22 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-22 08:09:51 | ROUTED TO R28 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-06-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-05-28 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-05-20 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2020-05-20 16:50:40 | ROUTED TO ZONING IN BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-03-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-03-09 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-02-18 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2020-02-24 15:20:19 | ROUTED FROM ZONING TO HISTORIC 2/24/20 EL | | 2020-02-19 13:48:54 | R28 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-02-13 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2020-02-13 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2020-01-13 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2020-02-13 15:38:26 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 2/13/20 EL | | 2020-01-14 13:39:49 | R21 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-10-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-10 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2019-10-24 10:15:12 | ROUTED FROM ZONING TO HISTORIC 8/24/19 EL | | 2019-10-10 14:55:38 | R07 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2020-05-26 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-05-26 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-05-26 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2020-05-26 08:44:52 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | MECHANICAL REVIEW APPROVED WITH PROVISO: | | | | | | AT TIME OF INSPECTION, PROVIDE AHRI SHEETS ON-SITE FOR | | | INSPECTOR. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2020-02-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-02-27 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-02-27 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2020-02-27 08:20:49 | 3RD REVIEW FBC-2017 MECHANICAL | | | PERMIT #19100568 | | | 2/27/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | COMMENTS REMAINING FROM THE 1ST REVIEW ARE LISTED | | | BELOW- PLEASE RESUBMIT CORRECTED PLANS AND THE | | | REQUESTED CALCULATIONS. | | | | | | 1) THE NEW ENERGY COMPLIANCE FORM R405-2017 LISTS THE | | | NEW A C SYSTEM AS A 24,000 BTUH (2-TON) 14 SEER SYSTEM, | | | HOWEVER THE EQUIPMENT SCHEDULED ON SHEET M-1 INDICATES | | | A 30,000 BTUH (2.5 TON) 13 SEER SYSTEM. PLEAAE MATCH | | | THE SYSTEMS ONE WAY OR THE OTHER. | | | | | | 2) 3RD REQUEST: PROVIDE MANUAL J COOLING AND HEATING | | | CALCULATIONS FOR THE NEW AC SYSTEM- SECTION R403.6.1 | | | FBC EC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-01-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-01-28 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-01-28 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2020-01-28 17:15:43 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19100568 | | | 1/28/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | COMMENTS REMAINING FROM THE 1ST REVIEW ARE LISTED | | | BELOW- PLEASE RESUBMIT CORRECTED PLANS AND THE | | | REQUESTED CALCULATIONS. | | | | | | 1) THE PREVIOUSLY NONCONDITIONED RESIDENCE NOW BEING | | | CONDITIONED MUST BE BROUGHT INTO FULL COMPLIANCE WITH | | | THE FBC-17 ENERGY CONSERVATION CODE- SECTION R503.2 FBC | | | EC. SUBMIT AN ENERGY COMPLIANCE FORM IN ACCORDANCE WITH | | | SECTION R101.5 FBC EC. | | | | | | 2) SUBMIT ACCA MANUAL J COOLING AND HEATING | | | CALCULATIONS FOR THE NEW AC SYSTEM- SECTION R403.6.1 | | | FBC EC. | | | | | | 3) SHEET M-1: REQUIRED RETURN AIR FROM BEDROOMS NOT | | | SHOWN ON THE PLAN- M1602.3 FBC RES. | | | | | | 4) M-1: IT APPEARS THAT THE REQUIRED 30X30 ACCESS SPACE | | | IN FRONT OF THE WATER HEATER WILL BE BLOCKED BY THE | | | DRYER- SECTION M1305.1 FBC RES. | | | | | | 5) M-1: INDICATE THE CLEAR OPENING DIMENSIONS OF THE | | | AIR HANDLER ATTIC ACCESS PANEL, AND VERIFY IT IS SIZED | | | LARGE ENOUGH TO ALLOW REMOVAL OF THE APPLIANCE- SECTION | | | M1305.1.3 FBC RES. | | | | | | 6) M-1: EXHAUST VENTILATION AT A RATE OF 100 CFMS | | | INTERMITTENT OR 25 CFMS CONTINUOUS SHALL BE PROVIDED | | | FOR THE KITCHEN- TABLE M1507.4 FBC RES. PLEASE SEE | | | SECTION M1503.1 FOR RANGE HOOD REQUIREMENTS, AND | | | M1503.4 FOR MAKEUP AIR. | | | | | | 7) M-1: VERIFY COMPLIANCE WITH SECTION R403.3.6 FBC EC | | | AIR-HANDLING UNITS IN ATTICS: | | | | | | AIR-HANDLING UNITS SHALL NOT BE INSTALLED IN THE ATTIC | | | WHEN A HOME IS BROUGHT INTO CODE COMPLIANCE BY SECTION | | | R402. AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS FOR | | | COMPLIANCE BY SECTION R405 ONLY IF THE FOLLOWING | | | CONDITIONS ARE MET: | | | | | | 1.THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | | | | | 2.A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT DOWN | | | THE UNIT WHEN THE CONDENSATION DRAIN IS NOT WORKING | | | PROPERLY. | | | | | | 3.THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | | REPLACE THE AIR HANDLER. | | | | | | 4.A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | | CAPITALS, IN 16-POINT TYPE, WITH THE TITLE AND FIRST | | | PARAGRAPH IN BOLD: | | | | | | NOTICE TO HOMEOWNER | | | A PART OF YOUR AIR-CONDITIONING SYSTEM, THE AIR | | | HANDLER, IS LOCATED IN THE ATTIC. FOR PROPER, EFFICIENT | | | AND ECONOMIC OPERATION OF THE AIRCONDITIONING SYSTEM, | | | YOU MUST ENSURE THAT REGULAR MAINTENANCE IS PERFORMED. | | | YOUR AIR-CONDITIONING SYSTEM IS EQUIPPED WITH ONE OR | | | BOTH OF THE FOLLOWING: (1) A DEVICE THAT WILL ALERT YOU | | | WHEN THE CONDENSATION DRAIN IS NOT WORKING PROPERLY OR | | | (2) A DEVICE THAT WILL SHUT DOWN THE SYSTEM WHEN THE | | | CONDENSATION DRAIN IS NOT WORKING. TO LIMIT POTENTIAL | | | DAMAGE TO YOUR HOME, AND TO AVOID DISRUPTION OF | | | SERVICE, IT IS RECOMMENDED THAT YOU ENSURE PROPER | | | WORKING ORDER OF THESE DEVICES BEFORE EACH SEASON OF | | | PEAK OPERATION. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-10-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-10-29 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-10-29 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2019-10-29 14:46:06 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19100568 | | | 10/29/19 | | | | | | CODES IN EFFECT: | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE PREVIOUSLY NONCONDITIONED RESIDENCE NOW BEING | | | CONDITIONED MUST BE BROUGHT INTO FULL COMPLIANCE WITH | | | THE FBC-17 ENERGY CONSERVATION CODE- SECTION R503.2 FBC | | | EC. SUBMIT AN ENERGY COMPLIANCE FORM IN ACCORDANCE WITH | | | SECTION R101.5 FBC EC. | | | | | | 2) SUBMIT ACCA MANUAL J COOLING AND HEATING | | | CALCULATIONS FOR THE NEW AC SYSTEM- SECTION R403.6.1 | | | FBC EC. | | | | | | 3) SHEET M-1: REQUIRED RETURN AIR FROM BEDROOMS NOT | | | SHOWN ON THE PLAN- M1602.3 FBC RES. | | | | | | 4) M-1: IT APPEARS THAT THE REQUIRED 30X30 ACCESS SPACE | | | IN FRONT OF THE WATER HEATER WILL BE BLOCKED BY THE | | | DRYER- SECTION M1305.1 FBC RES. | | | | | | 5) M-1: INDICATE THE CLEAR OPENING DIMENSIONS OF THE | | | AIR HANDLER ATTIC ACCESS PANEL, AND VERIFY IT IS SIZED | | | LARGE ENOUGH TO ALLOW REMOVAL OF THE APPLIANCE- SECTION | | | M1305.1.3 FBC RES. | | | | | | 6) M-1: EXHAUST VENTILATION AT A RATE OF 100 CFMS | | | INTERMITTENT OR 25 CFMS CONTINUOUS SHALL BE PROVIDED | | | FOR THE KITCHEN- TABLE M1507.4 FBC RES. PLEASE SEE | | | SECTION M1503.1 FOR RANGE HOOD REQUIREMENTS, AND | | | M1503.4 FOR MAKEUP AIR. | | | | | | 7) M-1: VERIFY COMPLIANCE WITH SECTION R403.3.6 FBC EC | | | AIR-HANDLING UNITS IN ATTICS: | | | | | | AIR-HANDLING UNITS SHALL NOT BE INSTALLED IN THE ATTIC | | | WHEN A HOME IS BROUGHT INTO CODE COMPLIANCE BY SECTION | | | R402. AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS FOR | | | COMPLIANCE BY SECTION R405 ONLY IF THE FOLLOWING | | | CONDITIONS ARE MET: | | | | | | 1.THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | | | | | 2.A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT DOWN | | | THE UNIT WHEN THE CONDENSATION DRAIN IS NOT WORKING | | | PROPERLY. | | | | | | 3.THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | | REPLACE THE AIR HANDLER. | | | | | | 4.A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | | CAPITALS, IN 16-POINT TYPE, WITH THE TITLE AND FIRST | | | PARAGRAPH IN BOLD: | | | | | | NOTICE TO HOMEOWNER | | | A PART OF YOUR AIR-CONDITIONING SYSTEM, THE AIR | | | HANDLER, IS LOCATED IN THE ATTIC. FOR PROPER, EFFICIENT | | | AND ECONOMIC OPERATION OF THE AIRCONDITIONING SYSTEM, | | | YOU MUST ENSURE THAT REGULAR MAINTENANCE IS PERFORMED. | | | YOUR AIR-CONDITIONING SYSTEM IS EQUIPPED WITH ONE OR | | | BOTH OF THE FOLLOWING: (1) A DEVICE THAT WILL ALERT YOU | | | WHEN THE CONDENSATION DRAIN IS NOT WORKING PROPERLY OR | | | (2) A DEVICE THAT WILL SHUT DOWN THE SYSTEM WHEN THE | | | CONDENSATION DRAIN IS NOT WORKING. TO LIMIT POTENTIAL | | | DAMAGE TO YOUR HOME, AND TO AVOID DISRUPTION OF | | | SERVICE, IT IS RECOMMENDED THAT YOU ENSURE PROPER | | | WORKING ORDER OF THESE DEVICES BEFORE EACH SEASON OF | | | PEAK OPERATION. | | | | | | 8) M-1: PROVIDE A CONDENSATE DISPOSAL PLAN SHOWING THE | | | PIPING RUN AND DISHARGE LOCATION, AND THE TYPE AND SIZE | | | OF PIPE- SECTION M1411.3 FBC RES. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-22 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-22 |
Time |
08:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2020-01-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-01-28 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-01-28 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2020-01-28 15:02:17 | NOA 16-0811.11 SHINGLE ROOF - OK | | | NOA 18-0919.12 FLAT ROOF WITH ENHANCED NAILING ATTACHED | | | - OK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2021-02-19 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2021-02-19 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2021-02-19 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2021-02-19 12:26:19 | LANDSCAPE PERMIT SUBMITTED - TO BE REVIEWED BY RAY | | | CARANCI | | | | | | PROVISO: | | | UNPERMITTED FENCE SHALL NEED TO BE REMOVED - ANY NEW | | | FENCE REQUIRES SEPARATE PERMIT | | | | | | | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2020-05-21 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-05-21 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-05-21 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2020-05-21 15:36:13 | LANDSCAPE PERMIT SUBMITTED - TO BE REVIEWED BY RAY | | | CARANCI | | | | | | PROVISO: | | | UNPERMITTED FENCE SHALL NEED TO BE REMOVED - ANY NEW | | | FENCE REQUIRES SEPARATE PERMIT | | | | | | | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2020-02-24 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-02-24 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-02-24 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2020-02-24 15:19:51 | REPEAT COMMENTS: | | | | | | PLEASE SUBMIT A LANDSCAPE PERMIT MEETING REQUIREMENTS | | | PER SECTION 94-442 | | | MUST BE SUBMITTED PRIOR TO ZONING SIGN OFF | | | | | | CONTACT RAY CARANCI, LANDSCAPE PLANNER WITH ANY | | | QUESTIONS 561 822 1462 | | | | | | | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-02-13 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-02-13 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-02-13 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2020-02-13 15:38:04 | REPEAT COMMENTS: | | | | | | PLEASE SUBMIT A LANDSCAPE PERMIT MEETING REQUIREMENTS | | | PER SECTION 94-442 | | | MUST BE SUBMITTED PRIOR TO ZONING SIGN OFF | | | | | | CONTACT RAY CARANCI, LANDSCAPE PLANNER WITH ANY | | | QUESTIONS 561 822 1462 | | | | | | UNPERMITTED FENCE SHALL NEED TO BE REMOVED - ANY NEW | | | FENCE REQUIRES SEPARATE PERMIT | | | | | | | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-10-24 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-10-24 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-10-24 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2019-10-24 10:14:48 | PLEASE SUBMIT A LANDSCAPE PERMIT MEETING REQUIREMENTS | | | PER SECTION 94-442 | | | MUST BE SUBMITTED PRIOR TO ZONING SIGN OFF | | | | | | CONTACT RAY CARANCI, LANDSCAPE PLANNER WITH ANY | | | QUESTIONS 561 822 1462 | | | | | | UNPERMITTED FENCE SHALL NEED TO BE REMOVED - ANY NEW | | | FENCE REQUIRES SEPARATE PERMIT | | | | | | PLEASE ADDRESS EXISTING GARAGE - WILL THIS BE REMOVED? | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 |
|
|
|