| Plan Review Stops For Permit 19100398 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-12-02 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-12-02 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-11-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-11-14 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-11-14 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2019-11-14 14:59:36 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE ARCHITECT'S DIGITAL SIGNATURES ON THE | | | ARCHITECTURAL SHEETS COULD NOT BE VEIFIED. THERE | | | APPEARS TO BE AN ERROR IN THE UPLOADING OF THE | | | DIGITALLY SIGNED ARCHITECTURAL SHEETS. FAC 61G1-16.003 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-10-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-10-16 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-10-16 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2019-10-16 15:56:10 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE COVERSHEET A-000 WAS NOT DIGITALLY SIGNED BY THE | | | ARCHITECT. FAC 61G1-16.003 | | | | | | 2) THE DEMOLITION PLAN A-100 IS LISTED IN THE PLAN | | | INDEX BUT IS MISSING FROM THE SUBMITTAL. FBC 107.2.1 | | | | | | 3) ELEVATION #7 ON A-250 HAS A DIMENSION FOR THE | | | BREAK-ROOM SINK AS 3'-0". FBC ACCESSIBILITY SECTION | | | 606.3 REQUIRES THE HIGHER OF THE SINK RIM OR COUNTER | | | TOP TO BE A MAXIMUM OF 34". | | | | | | 4) FBC ACCESSIBILITY SECTION 904.4.1 FOR A PARALLEL | | | APPROACH REQUIRES A PORTION OF THE SERVICE COUNTER AT | | | THE RECEPTION DESK TO BE A MINIMUM OF 36" IN LENGTH. | | | DETAIL 15 ON A-250 SPECIFIES 34.5". | | | | | | 5) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-11-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-11-21 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-11-21 |
Time |
09:07 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-10-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-10-17 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-10-17 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-11-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-11-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-11-27 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-11-20 |
|
|
Cont ID |
|
| Sent By |
sathomas |
Date |
2019-11-20 |
Time |
00:00 |
Rev Time |
0.00 |
| Received By |
sathomas |
Date |
2019-11-20 |
Time |
00:00 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-10-18 |
|
|
Cont ID |
|
| Sent By |
sathomas |
Date |
2019-10-18 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
sathomas |
Date |
2019-10-18 |
Time |
00:00 |
Sent To |
I |
|
| Notes |
| 2019-10-18 13:04:54 | 1. PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND | | | DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF | | | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | 2. PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION | | | SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND | | | RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION | | | SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A | | | 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A | | | FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED | | | BY EMAIL ([email protected]) OR IN WRITING (FAX: | | | 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE | | | MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.? | | | 3. ENGINEERED FIRE ALARM AND FIRE SPRINKLER | | | CONSTRUCTION DOCUMENTS ARE REQUIRED FOR A GENERAL | | | BUILDING PERMIT. AFTER THE BUILDING PERMIT HAS BEEN | | | ISSUED, THE SUBCONTRACTORS CAN THEN SUBMIT SHOP | | | DRAWINGS (CONFORMING TO THE ENGINEERED CONSTRUCTION | | | DOCUMENTS) FOR A SUB-PERMIT. | | | 4. SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | 5. EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A | | | MINIMUM OF 1.5 HOURS IN THE EVENT OF FAILURE OF NORMAL | | | LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE | | | ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT | | | LESS THAN AN AVERAGE OF 1 FT-CANDLE AND, AT ANY POINT, | | | NOT LESS THAN 0.1 FT-CANDLE, MEASURED ALONG THE PATH OF | | | EGRESS AT FLOOR LEVEL. | | | | | | S.THOMAS | | | 561-804-4728 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-12-05 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-12-05 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-11-21 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-11-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-11-12 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-10-22 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-09 |
Time |
11:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-12-03 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-12-03 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-11-21 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2019-12-03 10:31:59 | NO FEES DUE - NO RECEIPT CREATED | | 2019-11-21 11:42:06 | 11/21/19 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-10-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-10-16 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-10-16 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2019-10-16 15:38:55 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-11-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-11-18 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-11-18 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-10-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-10-15 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-10-11 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2019-10-15 10:47:45 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19100398 | | | 10/15/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-300: PROVIDE EXHAUST VENTILATION | | | CALCULATIONS FOR THE FLEX INJECTION, COOL SCULPTING, | | | AND LHR ROOMS- TABLE 403.3.1.1 FBC M. | | | | | | 2) M-300: PROVIDE THE SEQUENCES OF OPERATION FOR THE | | | EXHAUST FANS (EF-1-6)- SECTION 501.4 FBC M. | | | | | | 3) SHEETS M103, M300: PLEASE INCLUDE EF-5 IN THE FAN | | | SCHEDULE- SECTION 107.2.1 FBC M. | | | | | | 4) S2: PROVIDE THE WIND DESIGN CRITERIA USED TO | | | DETERMINE THE ROOFTOP MECHANICAL EQUIPMENT ENGINEERING- | | | SECTION 301.15 FBC M, AND SECTION 1609 FBC B. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-11-18 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-11-18 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-10-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-17 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-11 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2019-10-17 16:58:06 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1.SHT. A-250 THE GRAB BARS SHALL BE MEASURED FROM | | | FINISHED FLOOR TO THE TOP OF THE GRIPPING SURFACE NOT | | | TO THE CENTER OF THE BAR AS SHOWN ON PLAN. PER FBC ACC | | | 609.4 | | | | | | 2. PLEASE LABEL CLEAR FLOOR FOR THE TOILET LAVATORY AND | | | WATER FOUNTAIN. PER FBC PL 604.3.1, 606.2, 602.2 | | | | | | 3. THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH | | | FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES | | | (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. PER | | | FBC PL 604.4 | | | | | | 4. THE BREAK ROOM SINK AND AT LEAST ONE OF THE | | | PROCEDURE ROOM SINKS SHALL COMPLY WITH FBC ACC 212.2, | | | 212.3, 606.2, 606.3, 804.4 | | | | | | 5. SHT. P-000 NOTE #29 HOT WATER PIPING SHALL COMPLY | | | WITH FBC ENERGY 2017 6TH EDITION | | | | | | 6. SHT. P-102 PLACE NOTE ON PLAN THE SANITARY VENT | | | SHALL A MIN OF 10' AWAY OF ANY AIR INTAKES OR OPENINGS. | | | PER FBC PL 903.5 | | | | | | 7. THE PLUMING SCHEDULE LIST FLOOR MOUNTED TOILETS AND | | | THE SANITARY ISOMETRIC SHOWS WALL MOUNTED PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 8. SHT. P-500 P-501, P-000 REMOVE ALL REFERENCES TO | | | DIVISION 22 THE GOVERNING CODE SHALL BE LISTED ON THE | | | PLAN AS FLORIDA BUILDING CODE PLUMBING 2017 6TH | | | EDITION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-12-02 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-12-02 |
Time |
11:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-11-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-11-14 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-11-14 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2019-11-14 15:01:29 | ARITECTURAL SHEETS DIGITAL SIGNATURES CAN NOT BE | | | VALIDATED. SIGNATURES ON STRUCTURAL PLAN SHEETS ARE | | | GOOD. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-10-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-10-16 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-10-16 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2019-10-16 15:34:54 | THE COVER SHEET A-000 IS NOT DIGITALLY SIGNED AND | | | SEALED BY THE ARCHITECT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-12-04 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-12-04 |
Time |
17:51 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2019-12-04 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2019-12-04 17:37:34 | PASSED WITH PROVISO | | | | | | IN THE EVENT THAT NEW EQUIPMENT IS VISIBLE, THE | | | EQUIPMENT NEEDS TO BE PAINTED WITH A SKY PATTERN PRIOR | | | TO THE FINAL INSPECTION (104) APPROVAL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-18 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-11-18 |
Time |
12:04 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2019-11-18 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2019-11-18 11:35:24 | PASSED WITH PROVISO | | | | | | IN THE EVENT THAT NEW EQUIPMENT IS VISIBLE, THE | | | EQUIPMENT NEEDS TO BE PAINTED WITH A SKY PATTERN PRIOR | | | TO THE FINAL INSPECTION (104) APPROVAL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-10-22 |
Time |
10:37 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2019-10-22 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2019-10-22 10:37:47 | FAILED | | | | | | PROVIDE WRITTEN RESPONSE TO COMMENTS. | | | | | | 1) THE PLANS EITHER NEED TO CONTAIN THE PALM BEACH | | | OUTLETS MANAGEMENT APPROVAL STAMP. ALTERNATIVELY YOU | | | MAY SUBMIT A SEPARATE LETTER FROM THE PBO MANAGEMENT | | | LISTING THE SPECIFIC PLANS THAT THEY APPROVE. | | | | | | 2) THE ROOF PLAN SHOWS A NEW ROOFTOP UNIT ON A CURB, | | | NEW MINI SPLIT CONDENSING UNIT ON AND EXISTING | | | EQUIPMENT STAND AND AN NEW MECHANICAL HOOD. PROVIDE | | | SITE LINE DRAWINGS SO THAT STAFF CAN VERIFY THAT THESE | | | NEW ITEMS COMPLY WITH THE PALM BEACH OUTLETS SCREENING | | | REQUIREMENTS. | | | | | | 3) PLEASE DESCRIBE WHAT YOU WILL OCCUR IN THE DISPLAY | | | AREA (ROOM 114). | | | | | | 4) PLEASE ELABORATE ON THE WINDOW FILM WC-2. WILL THIS | | | INCLUDE ADVERTISING OR GRAPHICS? PLEASE NOTE THAT YOU | | | MAY ONLY COVER A MAXIMUM OF 10% OF THE GLAZED AREA WITH | | | THE FILM. WHILE IT APPEARS THAT LESS THAN 10% IS | | | COVERED, PLEASE PROVIDE CALCULATIONS TO VERIFY. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | | | | |
|
|