Plan Review Details - Permit 19100019
Plan Review Stops For Permit 19100019
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-12-12 Cont ID  
Sent By jpearson Date 2019-12-12 Time 10:19 Rev Time 0.00
Received By jpearson Date 2019-12-12 Time 10:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-10-22 Cont ID  
Sent By jpearson Date 2019-10-22 Time 13:22 Rev Time 0.00
Received By jpearson Date 2019-10-22 Time 13:22 Sent To  
Notes
2019-10-22 13:21:24CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET)
 IS REQUIRED TO BEAR THE NAME AND BE SIGNED AND SEALED
 BY THE PERSON RESPONSIBLE FOR THE DESIGN. THIS PERSON
 MUST BE A LICENSED DESIGN PROFESSIONAL OR THE
 ELECTRICAL CONTRACTOR QUALIFIER. A DIGITAL PLAN
 REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD
 PARTY VERIFICATION. PROVIDE CORRECTION. WPB FBC 107.1,
 107.2; FS 471, 481
 2. FIRE ALARM AND ACCESS CONTROL ARE TWO DIFFERENT
 PERMIT TYPES AND SHOULD BE APPLIED FOR SEPARATELY.
 REMOVE THE ACCESS CONTROL POTION OF THIS PLAN AND
 SUBMIT UNDER SEPARATE PERMIT. WPB FBC 105.1
 3. PROVIDE CLARIFICATION OF CONTRACT PRICES TO INCLUDE
 FIRE ALARM ONLY FOR THIS PERMIT. WHAT IS THE DIFFERENCE
 BETWEEN PRODUCTION AND NON-PRODUCTION PRICING? WHY IS
 THE NON-PRODUCTION PRICING BEING USED? VALUE FOR WORK
 STATED ON PERMIT APPLICATION SHALL INCLUDE ALL
 MATERIALS AND LABOR. PROVIDE CORRECTION AND/OR
 CLARIFICATIONS. WPB FBC 109.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-11-22 Cont ID  
Sent By pleduc Date 2019-11-22 Time   Rev Time 0.00
Received By pleduc Date 2019-11-22 Time 13:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-10-08 Cont ID  
Sent By pleduc Date 2019-10-08 Time   Rev Time 0.00
Received By pleduc Date 2019-10-08 Time 12:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-12-12 Time   Rev Time 0.00
Received By lmarchan Date 2019-11-21 Time 15:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-10-22 Time   Rev Time 0.00
Received By lmarchan Date 2019-10-03 Time 09:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-12-10 Cont ID  
Sent By ccole Date 2019-12-10 Time 12:13 Rev Time 0.00
Received By ccole Date 2019-12-10 Time 12:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-10-16 Cont ID  
Sent By ccole Date 2019-10-16 Time 13:34 Rev Time 0.00
Received By ccole Date 2019-10-16 Time 13:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-12-12 Cont ID  
Sent By jpearson Date 2019-12-12 Time 10:19 Rev Time 0.00
Received By jpearson Date 2019-12-12 Time 10:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-10-22 Cont ID  
Sent By jpearson Date 2019-10-22 Time 13:23 Rev Time 0.00
Received By jpearson Date 2019-10-22 Time 13:23 Sent To  
Notes
2019-10-22 13:22:31PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET) IS
 REQUIRED TO BEAR THE NAME AND BE SIGNED AND SEALED BY
 THE PERSON RESPONSIBLE FOR THE DESIGN. THIS PERSON MUST
 BE A LICENSED DESIGN PROFESSIONAL OR THE ELECTRICAL
 CONTRACTOR QUALIFIER. A DIGITAL PLAN REQUIRES A DIGITAL
 SIGNATURE WITH THE PROPER THIRD PARTY VERIFICATION.
 PROVIDE CORRECTION. WPB FBC 107.1, 107.2; FS 471, 481