| Plan Review Stops For Permit 19091122 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-10-21 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-10-17 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2019-10-21 16:29:59 | ASEBESTOS REMOVED IN DEMO PERMIT AND AIR QUALITY | | | REPORTS ARE PROVIDED AND PASS STANDARDS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-11-25 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-11-25 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-11-25 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-11-19 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-11-18 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-11-18 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2019-11-19 08:13:45 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19091122 | | | REVIEWED: NOVEMBER 19, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC[B] = FBC BUILDING | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | | | | THE EXISTING MEZZANINE WILL BE OK IF USED FOR STORAGE | | | ONLY, BUT PLEASE LABLE AS STORAGE AND NOT AS ATTIC. | | | | | | WE WILL LOOK AT IT AS MEZZANINE AND THE SQ. FOOTAGE | | | WILL ONLY BE USED FOR ENERGY CALULATION PURPOSES AS | | | THEY WERE RE-SUBMITTED. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-10-21 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-10-17 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2019-10-21 16:31:25 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19091122 | | | REVIEWED: OCTOBER 21, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC[B] = FBC BUILDING | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | | | | 1) 505 FBC[EXISTING]PLEASE CHANGE LEVEL OF ALTERATION | | | TO LEVEL 3 ON SHEET ALS1.1 SINCE ALTERATIONS OCCUR IN | | | MORE THAN 50% OF THE BUILDING AREA. | | | | | | 2) 501 GENERAL AREA. | | | THE SQ. FOOTAGE VARIES FROM PAPA AT 9792, SHEET ALS1.1 | | | AT 9140 AND ENERGY CALCS AT 10,979. PLEASE GIVE AN | | | OVERALL SQ. FOOTAGE FOR AREA CALCULATION. THE AREA SQ. | | | FOOTAGE CAN EXCLUDE THE MEZZANINE IF IT MEETS THE | | | REQUIREMENTS (SEE COMMENTS 4 AND 5). THE LIFE SAFETY | | | OCCUPANCY SQ. FOOTAGE CAN REMAIN AS SHOWN ON SHEET | | | ALS1.1. | | | ADJUST SQ. FOOTAGE ON ENERGY CALCS IF APPLICABLE. | | | ALSO, THE ENERGY CALCULATIONS INCLUDE NO INPUT DATA FOR | | | FLOORS, WALLS, WINDOWS, DOORS, SKYLIGHTS AND ROOF. I | | | HAVE NO DATA FOR INSULATION ON ROOF OR WALLS. PLEASE | | | PROVIDE DATA FOR BUILDING ENVELOPE. | | | | | | 3) TABLE 506.2 ALLOWS 9000 SQ. FT. FOR OCCUPANCY B TYPE | | | V-B CONSTRUCTION. IT APPEARS THAT YOU WOULD LIKE THE | | | MEZZANINE TO NOT COUNT TOWARDS THAT SQUARE FOOTAGE | | | LIMIT, SO PLEASE SHOW DETAILS THAT THE MEZZANINE MEETS | | | ALL CRITERIA FOR A MEZZANINE. | | | | | | 4) 505.2 MEZZANINES. A MEZZANINE OR MEZZANINES IN | | | COMPLIANCE WITH SECTION 505.2 SHALL BE CONSIDERED A | | | PORTION OF THE STORY BELOW. SUCH MEZZANINES SHALL NOT | | | CONTRIBUTE TO EITHER THE BUILDING AREA OR NUMBER OF | | | STORIES AS REGULATED BY SECTION 503.1. THE AREA OF THE | | | MEZZANINE SHALL BE INCLUDED IN DETERMINING THE FIRE | | | AREA. THE CLEAR HEIGHT ABOVE AND BELOW THE MEZZANINE | | | FLOOR CONSTRUCTION SHALL BE NOT LESS THAN 7 FEET (2134 | | | MM). | | | -WHAT IS THE CEILING HEIGHT IN MEZZANINE AREA? | | | | | | 5) 505.2.3 OPENNESS. A MEZZANINE SHALL BE OPEN AND | | | UNOBSTRUCTED TO THE ROOM IN WHICH SUCH MEZZANINE IS | | | LOCATED EXCEPT FOR WALLS NOT MORE THAN 42 INCHES (1067 | | | MM) IN HEIGHT, COLUMNS AND POSTS. | | | -IS THE MEZZANINE OPEN TO THE AREA THAT IT SERVES? | | | PLEASE SHOW DETAILS OF WHAT THE INTERIOR WALL CONSISTS | | | OF ON THE MEZZANINE LEVEL. I SEE A DETAIL FOR MEZZANINE | | | RAILING ON A3.1.2, BUT I DON?T SEE IT CALLED OUT ON | | | PLANS. | | | | | | PROVISOS: | | | A)DEFERRED SUBMITTALS-INTERIOR GLASS WALL SYSTEM, | | | ROOFING(WITH SUB-PERMIT APPLICATION) AND SKYLIGHTS | | | B)SEPARATE PERMITS REQUIRED FOR- | | | LOW VOLTAGE, ACCESS, LANDSCAPING, IRRIGATION. | | | C) CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO 8PM | | | SAT-SUN | | | - NO RESPONSE REQUIRED. THESE WILL BE ADDED TO THE | | | PLANS AT FINAL STAMPING. | | | | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-11-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-11-26 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-11-26 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-11-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-11-20 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-11-20 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-10-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-10-16 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-10-10 |
Time |
17:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-11-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-11-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-11-18 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-10-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-10-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-10-08 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-12-02 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-11-25 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-11-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-11-22 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-11-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-11-20 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-11-14 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-10-21 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-04 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-10-21 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-18 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2019-10-21 16:34:39 | NO IMPACT FEES DUE - SEE ATTACHED EMAIL. | | 2019-10-18 15:44:20 | 10/18/19 SENT TO IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2019-11-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-11-26 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-11-26 |
Time |
13:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2019-11-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-11-25 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-11-25 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2019-11-25 11:53:51 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19091122 | | | 11/25/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | SHEETS M3, P3, & E3 HAVE NOT BEEN CORRECTED. THE | | | STORAGE MEZZANNE IS STILL IDENTIFIED AS AN ATTIC- SEE | | | COMMENT BELOW. | | | | | | 1) SHEET M-3: THE EXISTING STORAGE MEZZANINE IS NOW | | | IDENTIFIED AS AN "ATTIC". PLEASE SEE SECTION 202 FBC EC | | | WHICH DEFINES ATTICS AS ENCLOSED UNCONDITIONED SPACES | | | ABOVE CEILINGS. THIS AREA IS CONDITIONED, IT'S SQUARE | | | FOOTAGE HAS BEEN ADDED TO THE REVISED ENERGY | | | CALCULATIONS (TOTAL 11208 SF), AND THE REVISED AC | | | CALCULATION FOR RTU- 2 INDICATES VENTILATION CFMS FOR | | | OCCUPANTS. PLEASE CLARIFY THE USE OF THE SPACE, AND | | | CORRECT THE IDENTIFICATION ON THE PLAN. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2019-11-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-11-19 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-11-18 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2019-11-19 07:58:35 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19091122 | | | 11/19/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-3: THE EXISTING STORAGE MEZZANINE IS NOW | | | IDENTIFIED AS AN "ATTIC". PLEASE SEE SECTION 202 FBC EC | | | WHICH DEFINES ATTICS AS ENCLOSED UNCONDITIONED SPACES | | | ABOVE CEILINGS. THIS AREA IS CONDITIONED, IT'S SQUARE | | | FOOTAGE HAS BEEN ADDED TO THE REVISED ENERGY | | | CALCULATIONS (TOTAL 11208 SF), AND THE REVISED AC | | | CALCULATION FOR RTU- 2 INDICATES VENTILATION CFMS FOR | | | OCCUPANTS. PLEASE CLARIFY THE USE OF THE SPACE, AND | | | CORRECT THE IDENTIFICATION ON THE PLAN. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-10-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-10-18 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-10-18 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2019-10-18 14:35:54 | LOCKED OUT OF M1, OPENED M2 FOR APPROVAL- CCOLE | | | 10/18/19 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-10-21 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-10-21 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-12-02 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-12-02 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2019-12-02 14:22:10 | PLUMBING PROVISO: | | | | | | PLUMBING COMMENTS: SHALL COMPLY PRIOR TO 2ND ROUGH | | | INSPECTION. | | | | | | 1. THE SHOWER GRAB BARS SHALL COMPLY WITH FBC ACC | | | 608.3.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENTS. | | | WHERE A SEAT IS PROVIDED IN STANDARD ROLL-IN TYPE | | | SHOWER COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ON THE | | | BACK WALL AND THE SIDE WALL OPPOSITE THE SEAT. GRAB | | | BARS SHALL NOT BE PROVIDED ABOVE THE SEAT. WHERE A SEAT | | | IS NOT PROVIDED IN STANDARD ROLL-IN TYPE SHOWER | | | COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ON THREE | | | WALLS. GRAB BARS SHALL BE INSTALLED 6 INCHES MAXIMUM | | | FROM ADJACENT WALLS. | | | 2. ALL GRAB BARS SHALL COMPLY WITH FBC ACC 609.4 | | | POSITION OF GRAB BARS.GRAB BARS SHALL BE INSTALLED IN A | | | HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | | THE GRIPPING SURFACE, | | | 3. THE ICE MAKER SHALL HAVE A BACKFLOW DEVICE ON SUPPLY | | | LINE. PER FBC PL 608.3 | | | 4. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3.PER FBC PL 416.5 | | | 5. HOT WATER PIPING SHALL BE INSULATED WITH 1? WALL | | | THICKNESS INSULATION. PER FBC ENER. TABLE C403.2.10 | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-11-18 |
Time |
06:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-11-18 |
Time |
06:44 |
Sent To |
|
|
| Notes |
| 2019-11-18 06:44:49 | REVIEWED REMOTELY BY TIM HUNT | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-21 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-18 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2019-10-21 09:08:20 | PLUMBING PROVISO: | | | | | | PLUMBING COMMENTS: SHALL COMPLY PRIOR TO 2ND ROUGH | | | INSPECTION. | | | | | | 1. THE SHOWER GRAB BARS SHALL COMPLY WITH FBC ACC | | | 608.3.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENTS. | | | WHERE A SEAT IS PROVIDED IN STANDARD ROLL-IN TYPE | | | SHOWER COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ON THE | | | BACK WALL AND THE SIDE WALL OPPOSITE THE SEAT. GRAB | | | BARS SHALL NOT BE PROVIDED ABOVE THE SEAT. WHERE A SEAT | | | IS NOT PROVIDED IN STANDARD ROLL-IN TYPE SHOWER | | | COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ON THREE | | | WALLS. GRAB BARS SHALL BE INSTALLED 6 INCHES MAXIMUM | | | FROM ADJACENT WALLS. | | | 2. ALL GRAB BARS SHALL COMPLY WITH FBC ACC 609.4 | | | POSITION OF GRAB BARS.GRAB BARS SHALL BE INSTALLED IN A | | | HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | | THE GRIPPING SURFACE, | | | 3. THE ICE MAKER SHALL HAVE A BACKFLOW DEVICE ON SUPPLY | | | LINE. PER FBC PL 608.3 | | | 4. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3.PER FBC PL 416.5 | | | 5. HOT WATER PIPING SHALL BE INSULATED WITH 1? WALL | | | THICKNESS INSULATION. PER FBC ENER. TABLE C403.2.10 | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2019-11-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-11-26 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-11-26 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-11-25 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-11-25 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-11-25 |
Time |
09:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-11-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-11-18 |
Time |
06:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-11-18 |
Time |
06:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2019-10-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-18 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-10-18 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2019-10-18 14:37:25 | MECH SHEETS OK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-10-18 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-10-18 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-10-18 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2019-10-18 16:05:21 | PROVISO: STEPS AND RAMP ON THE ALLEY EXIT CANNOT | | | ENCROACH INTO THE ALLEY ROW. |
|
|