| Plan Review Stops For Permit 19090964 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2019-10-09 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2019-10-09 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2019-10-09 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2019-10-07 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-10-07 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2019-10-07 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-07 13:19:10 | PLEASE ADDRESS FIRE COMMENTS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-10-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-10-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-10-09 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
bwoods |
Date |
2019-10-04 |
Time |
|
Rev Time |
|
| Received By |
bwoods |
Date |
2019-10-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-04 10:26:35 | PERMIT #19090964 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | | | | NFPA 24: | | | 4.1.3 WORKING PLANS SHALL BE DRAWN TO AN INDICATED | | | SCALE ON | | | SHEETS OF UNIFORM SIZE, WITH A PLAN OF EACH FLOOR AS | | | APPLICABLE, | | | AND SHALL INCLUDE THE FOLLOWING ITEMS THAT PERTAIN TO | | | THE DESIGN | | | OF THE SYSTEM: | | | (1) NAME OF OWNER | | | (2) LOCATION, INCLUDING STREET ADDRESS | | | (3) POINT OF COMPASS | | | (4) A GRAPHIC REPRESENTATION OF THE SCALE USED ON ALL | | | PLANS | | | (5) NAME AND ADDRESS OF CONTRACTOR | | | (6) SIZE AND LOCATION OF ALL WATER SUPPLIES | | | (7) SIZE AND LOCATION OF STANDPIPE RISERS, HOSE | | | OUTLETS, HAND | | | HOSE, MONITOR NOZZLES, AND RELATED EQUIPMENT | | | | | | BRITTANY WOODS | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4754 | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-10-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-10-10 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-08 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-10-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-10-07 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-09-24 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-10-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-10-08 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-10-08 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-10-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-10-01 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-10-01 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2019-10-01 11:28:02 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE UPLOADED PLAN IS A PHOTOCOPY OF THE FIRE | | | SPRINKLER PLAN WHICH INDICATES "UNDERGROUND BY OTHERS | | | UNDER SEPARATE PERMIT". AN ORIGINAL PLAN SIGNED AND | | | SEALED BY A LICENSED DESIGN PROFESSIONAL IS REQUIRED | | | PER SECTION 107.2.1 WPB. | | | | | | 2) THE $7500.00 VALUE ON THE PERMIT APPLICATION APPEARS | | | LOW FOR THE SCOPE OF THE PROJECT. THE TOTAL VALUE OF | | | THE PROJECT SHALL INCLUDE LABOR, MATERIALS, EQUIPMENT, | | | SITE WORK, AND DESIGN FEES- SECTION 109.3 WPB. PLEASE | | | PROVIDE COPIES OF CONTRACTS, INVOICES, AND ESTIMATES TO | | | VERIFY COSTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-10-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-10-08 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-10-08 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2019-10-08 15:11:16 | 10/8/19 ROUTED HARD COPIES TO CCOLE |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-10-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-10-08 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-10-08 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2019-10-08 09:50:33 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19090964 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE UPLOADED PLAN IS A PHOTOCOPY OF THE FIRE | | | SPRINKLER PLAN WHICH INDICATES "UNDERGROUND BY OTHERS | | | UNDER SEPARATE PERMIT". AN ORIGINAL ELECTRONICALLY | | | SIGNED AND SEALED PLAN BY A LICENSED DESIGN | | | PROFESSIONAL IS REQUIRED PER SECTION 107.2.1 WPB, AND | | | SECTION 61G15-23.005 FAC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | |
|
|