Plan Review Details - Permit 19090931
Plan Review Stops For Permit 19090931
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-12-27 Cont ID  
Sent By jgomez Date 2019-12-27 Time 14:30 Rev Time 0.00
Received By jgomez Date 2019-12-27 Time 14:06 Sent To  
Notes
2019-12-27 14:25:4012/27/19 NEW ENERGY CALCULATIONS SUBMITTED. JG.
  
  
 BUILDING REVIEW APPROVED WITH PROVISO.
 (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO
 INSPECTIONS):
 1-PROVIDE SIGNED & SEALED RAS 117 CALCULATIONS FOR FLAT
 ROOF NOA 18-0919.12 SUBMITTED.
 2- SINCE THIS PROPERTY IS LOCATED IN FLOOD ZONE AE,
 THEN ELEVATION CERTIFICATES ARE REQUIRED FOR BUILDING
 UNDER CONSTRUCTION AND FINISHED CONSTRUCTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-11-22 Cont ID  
Sent By jgomez Date 2019-11-22 Time 09:00 Rev Time 0.00
Received By jgomez Date 2019-11-21 Time 15:12 Sent To  
Notes
2019-11-21 18:09:15BUILDING REVIEW APPROVED WITH PROVISO.
 (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO
 INSPECTIONS):
 1-PROVIDE SIGNED & SEALED RAS 117 CALCULATIONS FOR FLAT
 ROOF NOA 18-0919.12 SUBMITTED.
 2- SINCE THIS PROPERTY IS LOCATED IN FLOOD ZONE AE,
 THEN ELEVATION CERTIFICATES ARE REQUIRED FOR BUILDING
 UNDER CONSTRUCTION AND FINISHED CONSTRUCTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-10-15 Cont ID  
Sent By jgomez Date 2019-10-15 Time 13:29 Rev Time 0.00
Received By jgomez Date 2019-10-15 Time 08:37 Sent To E
Notes
2019-10-15 13:34:26RESIDENTIAL (R3), ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1- THIS PROPERTY IS LOCATED IN A AREA WITH QUESTIONABLE
 SOIL. PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC.
 R401.4 FBC-RESIDENTIAL.
 NOTE: ARCHITECT SPECIFY VIBRO-COMPACTION ON THE
 BUILDING AREA ON SHEET A-4 AND SHEET S-1.
 VIBRO-COMPACTION TO BE COORDINATED WITH THE
 GEOTECHNICAL REPORT RECOMMENDATIONS.
  
 2- PLANS NEED TO PROVIDE SPECIFICATIONS FOR THE VAPOR
 RETARDER AS REQUIRED BY SEC. R506.2.3 FBC-RESIDENTIAL.
 NOTE: ALSO, PROVIDE SPECIFICATIONS SHOWING HOW THE
 VAPOR RETARDER WILL BE INSTALLED ON THE EXISTING
 CONCRETE SLAB THAT IS GOING TO RECEIVE THE NEW CONCRETE
 SLAB ON TOP.
  
 3- A) ROOF INSULATION SHOWN ON SECTION A-A ON SHEET S-1
 DOESN'T PROVIDE THE MIN. 1 INCH CLEARANCE REQUIRED BY
 SEC. R806.3 FBC-RESIDENTIAL FOR CROSS VENTILATION.
 REVISE AS REQUIRED TO COMPLY.
  
 B) ROOF VENT CALCULATIONS ARE REFERENCING THE 2014
 CODE. THE CURRENT CODE IS THE 2017 CODE, 6TH EDITION.
 REVISE AS REQUIRED.
 NOTE: THIS APPLIES TO THE "RENOVATION REQUIREMENTS" AND
 "GENERAL NOTES" ON SHEET A-1 ALSO. REVISE AS REQUIRED.
 CHAPTER 553 FLORIDA STATUTES
  
 4- PLANS ARE MISSING THE SPECIFICATIONS FOR BEAM #1 AND
 BEAM #2. PROVIDE COMPLETE DETAIL/SPECIFICATIONS. SEC.
 R301.1 FBC-RESIDENTIAL.
  
 5- FLASHING INFORMATION SHOWN ON SHEET A-5 CORRESPONDS
 TO WOOD FRAMED BUILDINGS. THIS DOESN'T MATCH PLANS.
 REVISE AS REQUIRED. PROVIDE FLASHING INFORMATION FOR
 CONCRETE BLOCK CONSTRUCTION. SEC. R703.1
 FBC-RESIDENTIAL.
  
 6- ACCORDING TO THE FLOOD INSURANCE RATE MAP WHICH WAS
 ADOPTED ON OCTOBER 5, 2017 AND IS APPLICABLE TO THIS
 PROJECT, THE STRUCTURE IS LOCATED IN AN AE FLOOD ZONE
 WHICH IS A SPECIAL FLOOD HAZARD AREA. THE BASE FLOOD
 ELEVATION FOR THE PROPERTY IS 12.1' NAVD 88. THE CITY
 OF WEST PALM BEACH HAS ADOPTED A FLOOD ORDINANCE THAT
 REQUIRES A TWO (2) FOOT FREE BOARD. THIS MEANS THAT THE
 LOWEST FLOOR AND ALL EQUIPMENT SERVICING THE RESIDENCE
 IS REQUIRED TO BE AT OR ABOVE 14.1' NAVD 88.
 BASED ON THE PROPERTY APPRAISER THE ADDITION IS
 CONSIDERED A SUBSTANTIAL IMPROVEMENT.
 THE ADDITION AND THE EXISTING HOUSE NEED TO COMPLY WITH
 THE FLOOD REQUIREMENTS.
  
 BASED ON THE SURVEY SUBMITTED, IT LOOKS LIKE THE
 FINISHED FLOOR OF THE EXISTING HOUSE MAY BE COMPLAINT
 WITH THE MIN. FINISHED FLOOR ELEVATION REQUIRED BY THE
 CITY FLOOD ORDINANCE (2 FEET ABOVE BASE FLOOD
 ELEVATION).
 BUT, SURVEY NEEDS TO BE REVISED. SURVEY IS MISMATCHING
 TWO DIFFERENT ELEVATION REFERENCES. THE INFORMATION
 UNDER THE LEGAL DESCRIPTION IS PROVIDING THE BASE FLOOD
 ELEVATION USING THE NAVD 88 REFERENCE, WHILE THE
 FINISHED FLOOR ELEVATION OF THE HOUSE IS IS USING NGVD
 29. REVISE SURVEY AS REQUIRED USING THE CURRENT
 REFERENCE NAVD 88.
  
 SINCE THIS PROPERTY IS LOCATED IN FLOOD ZONE AE, THEN
 ELEVATION CERTIFICATES ARE REQUIRED FOR BUILDING UNDER
 CONSTRUCTION AND FINISHED CONSTRUCTION. SEC. 18-284
 CITY ORDINANCE NO. 4729-17. NOTE: THIS WILL BE REQUIRED
 DURING CONSTRUCTION.
  
 7- ENERGY CALCULATIONS SUBMITTED:
 A) ENERGY FORM SUBMITTED R405-2014 IS FOR THE 2014
 CODE. THE CURRENT CODE IS THE 2017 6TH EDITION FBC.
 REVISE AS REQUIRED. PROVIDE CALCULATIONS USING THE
 CURRENT FORM.
 SEC. 1101.1 FBC-EXISTING BUILDING AND SEC. R101.5.1
 FBC-ENERGY CONSERVATION.
  
 B) THE ENERGY FORM IS REQUIRED TO BE CERTIFIED AT THE
 BOTTOM BY THE OWNER OR THE OWNER LEGALLY DESIGNATED
 AGENT AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 C) CEILING INSULATION SPECIFIED ON ITEM #10 DOESN'T
 MATCH ARCHITECTURAL PLANS. SEC. R101.5.1.1.2 SEE PLANS
 AND REVISE AS REQUIRED.
  
 D) PROVIDE THE NAME OF PERSON PERFORMING THE ANALYSIS
 AND GENERATING THE REPORT AS REQUIRED BY SEC.
 R405.4.2.1 FBC- ENERGY CONSERVATION
  
 E) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING THE BUILDER'S NAME. SEC. R101.5.1.1.2 FBC-
 ENERGY CONSERVATION.
  
 F)ROOF TYPE AND MATERIAL SPECIFIED ON PAGE 2 OF 4
 DOESN'T MATCH. SEE PLANS AND PRODUCT APPROVALS. REVISE
 AS REQUIRED. R101.5.1.1.2 FBC-RESIDENTIAL.
  
 G) REVISE THE ATTIC VENT RATIO ON PAGE 2 OF 4. THE
 RATIO IS 1/150 NOT 1/300. SEC. R806.2 FBC-RESIDENTIAL.
 OR, PERSON PREPARING THE ENERGY CALCULATIONS TO PROVIDE
 COMPLETE DOCUMENTATION SHOWING COMPLIANCE WITH THE
 1/300 RATIO AS REQUIRED BY THE EXCEPTION ON SEC.
 R806.2.
  
 H) REVISE WINDOWS OVERHANG DEPTH AND SEPARATION TO
 MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 I)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 NOTE:
 LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND
 SHGC FACTOR IS REQUIRED WHEN THE ENERGY CALCULATIONS
 ARE NOT USING THE DEFAULT FACTOR.
  
 8- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT
 APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL)
  
 A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. NOTE:
 IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 B)PRECAST LINTEL AS SPECIFIED ON PLANS. NOA 14-0903.03
 SUBMITTED IS FOR 4", 6" & 12" PRECAST LINTELS.
 ARCHITECT SPECIFIED 8" PRECAST LINTELS. ALSO, NOA
 SUBMITTED IS EXPIRED.
  
 9- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 10- IMPACT FEES -
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE
 DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-12-02 Cont ID  
Sent By jpearson Date 2019-12-02 Time 15:43 Rev Time 0.00
Received By jpearson Date 2019-12-02 Time 15:43 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-10-15 Cont ID  
Sent By jpearson Date 2019-10-15 Time 14:58 Rev Time 0.00
Received By jpearson Date 2019-10-15 Time 14:50 Sent To I
Notes
2019-10-15 14:58:42CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. AFCI PROTECTION SHOWN IN BLOCK NOTE BELOW PANEL
 SCHEDULE IS NOT CODE COMPLIANT. ALL BRANCH CIRCUITS
 THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE
 OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING
 ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
 BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND
 POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH
 AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1,
 801.2, OR 901.2 AS APPLICABLE.
 2. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS, OR PROVIDE A NOTE REQUIRING COMPLIANCE. IF NONE
 ARE EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS.
 FBC RE R314.3, R315.1; WPB FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-12-27 Cont ID  
Sent By jgomez Date 2019-12-27 Time 14:35 Rev Time 0.00
Received By jgomez Date 2019-12-27 Time 13:17 Sent To I
Notes
2019-12-27 13:17:45IMPACT FEES ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2019-12-20 Time   Rev Time 0.00
Received By lmarchan Date 2019-12-18 Time 14:43 Sent To  
Notes
2019-12-19 14:43:33RESUB ROTUED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-12-02 Time   Rev Time 0.00
Received By lmarchan Date 2019-11-12 Time 14:49 Sent To  
Notes
2019-11-13 14:50:00R33

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-10-15 Time   Rev Time 0.00
Received By lmarchan Date 2019-09-23 Time 14:15 Sent To  
Notes
2019-09-24 14:15:45R10

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2019-12-27 Cont ID  
Sent By jgomez Date 2019-12-27 Time 14:29 Rev Time 0.00
Received By jgomez Date 2019-12-27 Time 14:29 Sent To  
Notes
2019-12-27 14:29:50$1043.60 PAID. MU-2019-040284.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-11-22 Cont ID  
Sent By jgomez Date 2019-11-22 Time 09:35 Rev Time 0.00
Received By jgomez Date 2019-11-22 Time 09:35 Sent To  
Notes
2019-11-22 09:36:06IMPACT FEES -
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-10-15 Cont ID  
Sent By jgomez Date 2019-10-15 Time 13:35 Rev Time 0.00
Received By jgomez Date 2019-10-15 Time 13:35 Sent To  
Notes
2019-10-15 13:35:59IMPACT FEES -
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-12-20 Cont ID  
Sent By ccole Date 2019-12-20 Time 11:23 Rev Time 0.00
Received By ccole Date 2019-12-20 Time 11:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-11-27 Cont ID  
Sent By ccole Date 2019-11-27 Time 09:12 Rev Time 0.00
Received By ccole Date 2019-11-27 Time 08:18 Sent To  
Notes
2019-11-27 09:23:222ND REVIEW FBC-2017 MECHANICAL
 PERMIT #19090931
 11/27/2019
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENT #2 FROM THE 1ST REVIEW STILL EXIST- PLEASE
 COMPLY.
  
 2) REFER TO SECTION R403.7.1 FBC EC: THE SUBMITTED AC
 COOLING AND HEATING LOAD CALCULATIONS ARE INCOMPLETE.
 MISSING FROM THE PROJECT SUMMARY IS THE DIRECTIONAL
 ORIENTATION OF THE ADDITION AND THE COOLING AND HEATING
 EQUIPMENT SUMMARIES.
 PLEASE INDICATE IN THE NOTES ON THE FORM THAT THE
 CALCULATIONS ARE FOR THE NEW FAMILY ROOM ADDITION.
  
 1) NEW COMMENT SHEET M-1: PROVIDE A N AC EQUIPMENT
 SCHEDULE ON THE NEW MECHANICAL PLAN- SECTIPON 107.2.1
 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-10-08 Cont ID  
Sent By ccole Date 2019-10-08 Time 14:26 Rev Time 0.00
Received By ccole Date 2019-10-08 Time 14:25 Sent To  
Notes
2019-10-08 14:45:361ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19090931
 10/8/2019
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) INCOMPLETE MECHANICAL PLANS BY ENERGY HOUSE
 TECHNOLOGY FOR THE NEW ADDITION HAVE BEEN SUBMITTED.
 PLEASE PROVIDE A CLEAR PLAN DRAWN AT MINIMUM 1/8" SCALE
 THAT SHOWS THE LOCATIONS OF THE AIR HANDLER AND
 CONDENSER, AND INCLUDES AN EQUIPMENT SCHEDULE AND DUCT
 LAYOUT- SECTION 107.2.1 WPB.
  
 2) REFER TO SECTION R403.7.1 FBC EC: THE SUBMITTED AC
 COOLING AND HEATING LOAD CALCULATIONS ARE INCOMPLETE.
 MISSING FROM THE PROJECT SUMMARY IS THE DIRECTIONAL
 ORIENTATION OF THE ADDITION AND THE COOLING AND HEATING
 EQUIPMENT SUMMARIES.
  
 3) PROVIDE A COMPLETE ENERGY COMPLIANCE REPORT FOR THE
 NEW ADDITION USING EITHER THE PRECRIPTIVE COMPLIANCE
 PATH (FORM R402) OR THE PERFORMANCE PATH (R405
 GENERATED BY ENERGYGAUGE SOFTWARE). THERE ARE MANY
 PAGES MISSING FROM THE CURRENT PERFORMANCE SUBMITTAL
 INCLUDING THE COVER PAGE AND THE COMPLIANCE DATA PAGES-
 SEE SECTION R101.5.1.1 FBC EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2019-11-21 Cont ID  
Sent By jgomez Date 2019-11-21 Time 17:06 Rev Time 0.00
Received By jgomez Date 2019-11-21 Time 17:06 Sent To  
Notes
2019-11-21 17:07:541- PROPERTY IS LOCATED IN FLOOD ZONE AE WITH BASED
 FLOOR ELEVATION 12.1 NAVD 88. ELEVATION CERTIFICATES
 ARE REQUIRED BASED ON CONSTRUCTION DRAWINGS, BUILDING
 UNDER CONSTRUCTION AND FINISHED CONSTRUCTION. PROVIDE
 THE REQUIRED ELEVATION CERTIFICATES. SEC. 18-284 CITY
 ORDINANCE NO. 4729-17.

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2019-10-15 Cont ID  
Sent By jgomez Date 2019-10-15 Time 13:39 Rev Time 0.00
Received By jgomez Date 2019-10-15 Time 13:37 Sent To  
Notes
2019-10-15 13:40:011- PROPERTY IS LOCATED IN FLOOD ZONE AE WITH BASED
 FLOOR ELEVATION 12.1 NAVD 88. ELEVATION CERTIFICATES
 ARE REQUIRED BASED ON CONSTRUCTION DRAWINGS, BUILDING
 UNDER CONSTRUCTION AND FINISHED CONSTRUCTION. PROVIDE
 THE REQUIRED ELEVATION CERTIFICATES. SEC. 18-284 CITY
 ORDINANCE NO. 4729-17.

Review Stop P PLUMBING
Rev No 1 Status N Date 2019-10-03 Cont ID  
Sent By lcrespo Date 2019-10-03 Time 17:45 Rev Time 0.00
Received By lcrespo Date 2019-10-03 Time 17:45 Sent To  
Notes
2019-10-03 17:46:44ACCORDING TO THE SCOPE OF WORK NO PLUMBING SHALL BE
 MOVE OR ALTERED AS PER PLANS. NO PERMIT FOR PLUMBING
 REQUIRED.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-11-22 Cont ID  
Sent By jgomez Date 2019-11-22 Time 09:19 Rev Time 0.00
Received By jgomez Date 2019-11-22 Time 09:19 Sent To  
Notes
2019-11-22 09:20:16BUILDING REVIEW APPROVED WITH PROVISO.
 (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO
 INSPECTIONS):
 1-PROVIDE SIGNED & SEALED RAS 117 CALCULATIONS FOR FLAT
 ROOF NOA 18-0919.12 SUBMITTED.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-10-15 Cont ID  
Sent By jgomez Date 2019-10-15 Time 13:34 Rev Time 0.00
Received By jgomez Date 2019-10-15 Time 13:34 Sent To  
Notes
2019-10-15 13:35:101- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT
 APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL)
  
 A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. NOTE:
 IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 2- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-11-22 Cont ID  
Sent By rfalcone Date 2019-11-22 Time 08:30 Rev Time 0.00
Received By rfalcone Date 2019-11-22 Time 08:30 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-09-26 Cont ID  
Sent By rfalcone Date 2019-09-26 Time 15:05 Rev Time 0.00
Received By rfalcone Date 2019-09-26 Time 15:05 Sent To I
Notes
2019-09-26 15:07:2609/26/19 FAILED.
  
 PLEASE PROVIDE THE SETBACKS AND BUILDING HEIGHT FOR THE
 PROPOSED ADDITION IN PLAN SETS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 RACHEL FALCONE, ASSOCIATE PLANNER
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: (561) 822-1442
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved