| Plan Review Stops For Permit 19090792 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-02-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-01 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-02-01 |
Time |
06:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-12-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-14 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-12 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-19 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-03 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2019-10-19 11:01:27 | BUILDING PLAN REVIEW | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | ADMINISTRATIVE NOTICE: | | | | | | A SEPERATE PERMIT NUMBER (19100856) HAS BEEN ASSIGNED | | | TO THE CABANA. A VALUE OF $30,000.00 HAS BEEN ASSIGNED | | | TO IT WITH A CORRESPONDING REDUCTION IN VALUE OF THE | | | MAIN RESIDENCE, PERMIT NUMBER (19090792). | | | | | | 1. AN ELEVATION CERTIFICATE IS REQUIRED. SEE COMMENTS | | | UNDER THE NFIP REVIEW. | | | | | | 2. PROVIDE A SOILS REPORT. | | | R401.4 SOIL TESTS. | | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | | APPROVED METHOD. | | | | | | 3. PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. | | | SEE COMMENTS UNDER THE IMPACT FEE REVIEW. | | | | | | 4. THIS PROPERTY IS LOCATED WITHIN A HISTORIC DISTRICT. | | | DEFERRAL OF PRODUCT APPROVALS AS NOTED ON PLAN PAGE | | | A-0.0 ARE NOT ALLOWED. SUBMIT ALL PRODUCT APPROVALS FOR | | | REVIEW. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-02-04 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-02-04 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-01-30 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2020-02-04 11:40:28 | OK PER CHRIS TROOP | | | | | | I ACCIDENTLY CHECKED IN PLAN BY MISTAKE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-16 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-12 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2019-12-16 09:21:56 | PLAN REVIEW - ELECTRICAL | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE SERVICE OUTLET AT CU-1 & CU-6. | | | E3901.12 HVAC OUTLET. | | | | | | 2. AVAILABLE FAULT CURRENT FROM FPL TRANSFORMER IS | | | 30684. FAULT CURRENT USED ON PAGE E-5 FOR AVAILABLE | | | FAULT CURRENT CALCULATIONS IS 52,205. PLEASE CORRECT. | | | PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT CURRENT | | | AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE. NEC | | | 110.10 & FBC RE E3404.3 | | | | | | 3. REMOVE PANEL DP FROM RISER DIAGRAHM. PANEL DP IS TO | | | BE REMOVED FROM SOW PER RESPONSE LETTER FROM DESIGNER. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 4. PANEL B SHOWS A TOTAL LOAD OF 119 AMPS. OVERCURRENT | | | PROTECTION FROM MDP IS 100 AMPS. PLEASE CORRECT. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-10-12 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-10-12 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-10-10 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2019-10-12 12:26:46 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FIRST FLOOR | | | | | | 1. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS.(FOYER AND FAMILY ROOM) FIXED | | | PANELS IN FAMILY ROOM COUNT FOR WALL SPACING. | | | | | | RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT | | | MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL | | | SPACE IS MORE THAN 6 FEET FROM A RECEPTACLE OUTLET. | | | PROVIDE CORRECTION. NEC 210.52; FBC RE E3901.2.1 | | | | | | 2.PROVIDE NOTE ON PLAN STATING LOW VOLTAGE, GENERATOR, | | | AND ELEVATOR WILL REQUIRE SEPARATE PERMITS. FBC 107.2.1 | | | FBC 105.1 | | | | | | 3. RECEPTACLE REQUIRED FOR PATIO OUTSIDE OF BEDROOM #1 | | | NEC 210.52E3 | | | | | | 4. DISCONNECTS BEHIND CU2 DO NOT HAVE THE REQUIRED | | | WORKING CLEARANCE. NEC 110.26A | | | | | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | | | | 6. RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS SHALL | | | HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8(A)(9); FBC RE E3902.9 | | | | | | SECOND FLOOR, | | | | | | 1. RECEPTACLES REQUIRED ON ALL BALCONIES OUTSIDE. NEC | | | 210.52E3 | | | | | | 2.PROVIDE GFCI PROTECTED RECEPTACLE OUTLET AND SWITCH | | | CONTROLLED LIGHT FOR SERVICING EACH AHU LOCATED IN AN | | | ATTIC. FBC MECHANICAL CODE M306.3.1 | | | | | | 3. RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS SHALL | | | HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8(A)(9); FBC RE E3901.2.9 | | | | | | SERVICE/RISER | | | | | | 1. FAULT CURRENT CALCULATION FOR SERVICE IS BLURRY AND | | | NOT READABLE, ALSO PROVIDE FAULT CURRENT LETTER FROM | | | POWER UTILITY (FPL). FBC 107.2.1 | | | | | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | | | | 3. LOCATION OF DOCK PANEL NOT SHOWN? HOW FAR AWAY FROM | | | SERVICE IS DOCK PANEL LOCATED AND WHAT IS THE VOLTAGE | | | DROP? FBC 107.2.1 | | | | | | 4. PANEL SCHEDULE FOR DOCK NOT SHOWN, WHAT IS LOAD OF | | | DOCK PANEL? FBC 107.2.1 | | | | | | 5.THE RISER DIAGRAM SHOWS THE FEEDERS FOR ALL PANELS | | | FED FROM MDP, EXCEPT PANEL B, AS "TWO SETS OF 350 MCM | | | CU". SHOW ACTUAL FEEDER SIZE FOR ALL PANELS. FBC | | | 107.2.1 | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2020-02-04 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-02-04 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-02-04 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2020-02-04 10:46:42 | GAS COMMENTS: APPROVED | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-12-19 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-12-19 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-12-19 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2019-12-19 13:04:13 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | NFPA 99 = HEALTH CARE FACILITIES CODE | | | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 2ND REVIEW | | | GAS COMMENTS: DENIED | | | | | | 1. PLAN SHEET P-4: GAS RISER DIAGRAM IS MISSING SECOND | | | FLOOR FIREPLACE. PER WPB FBC 107.2.1 AND 107.3.5.3 | | | (12), INCLUDE IN DIAGRAM. | | | 2. PLAN SHEET P-4 REGARDING "GAS NOTES & CALCULATIONS", | | | DELETE NOTE "PROVIDE A 1-1/4" GAS LINE PER:". | | | 3. PLAN SHEET A-1.1 AND A-2.2 DO NOT NOTE TWO OF THE | | | FIVE FIREPLACES NOTED ON PLAN SHEETS P-1 AND P-2 AND ON | | | P-4 TOTAL GAS LOAD GAS EQUIPMENT SCHEDULE. PER WPB FBC | | | 107.2.1, PLEASE CLARIFY. | | | 4. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE, | | | TERMINATION POINT, HEIGHT ABOVE THE ROOF AND ANCHORING | | | DETAILS OF THE GAS VENT(S) FOR FIREPLACES PER FBC FG | | | SECTIONS 502 THRU 505 OR FBC RES SECTIONS G2426 THROUGH | | | G2439. | | | 5. PER WPB FBC 107.2.1, PROVIDE A NOTE STATING "PLASTIC | | | PIPE SHALL BE INSTALLED OUTDOORS UNDERGROUND ONLY. | | | PLASTIC PIPE SHALL NOT BE USED WITHIN OR UNDER ANY | | | BUILDING OR SLAB." TO COMPLY WITH FBC FG 404.17.1 AND | | | FBC RES G2415.17.1. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19090792 3030 WASHINGTON RD |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-23 |
Time |
05:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-10-21 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2019-10-21 10:51:48 | GAS 1ST REVIEW**DENIED** A SEPARATE GAS PERMIT FOR THE | | | HOME AND SEPARATE GENERATOR PERMIT IS REQUIRED. FBC | | | 105.1 | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER. 2017 FBC-RES | | | SEC. G2413.4.1, G2413.4.2. SECTION OF PIPING WHICH I | | | BUBBLED IN ON THE ISOMETRIC ARE MISSING CUT SECTIONS. | | | PLEASE ADD TO CLARIFY. | | | | | | 2. YOUR CALCULATIONS FOR COMBUSTION AIR LIST AN AIR KIT | | | IS REQUIRED FOR THE LIBRARY IS REQUIRED. PLEASE PROVIDE | | | HOW YOU INTENT TO COMPLY WITH THE REQUIRED MAKE UP AIR. | | | FBCR G2407.9.3 | | | | | | 3. SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2017 FBC-RES. SEC. G2421.1. | | | | | | 4. SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE | | | LOCATION OF THE TANKLESS WATER HEATER AND THE LOCATION | | | AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN | | | RELATION TO THE WATER HEATER. THE LOCATION OF THE WATER | | | HEATER SHALL COMPLY WITH THE MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND | | | DRAWN. WPB AMEND. TO FBC SEC. 107.2.1. IT APPEARS THE | | | TANKLESS OUTSIDE OF BATHROOM #1 MAY BE TOO CLOSE. | | | | | | 5. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 6. R405/2017 FORM ONLY LIST 1 TANKLESS GAS WATER HEATER | | | THIS HOME HAS 3. PLEASE CORRECT AND SUBMIT MANUFACTURES | | | INSTALLATION MANUAL TO SHOW THEY COMPLY WITH THE 2017 | | | FLORIDA ENERGY CODE AND FEDERAL MIN STANDARDS. FBC | | | 107.3.5 | | | | | | 7. PLEASE ADD NOTE THAT ALL EXTERIOR PIPING SHALL HAVE | | | A PROTECTIVE PAINT COATING. NFPA 54 | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | 561-248-2703 | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-02-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-02-06 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-02-06 |
Time |
15:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-10-08 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-10-08 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-10-08 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-02-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-02-06 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-01-27 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-12-24 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-12-09 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-10-31 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-10-31 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-01 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-02-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-02-06 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-21 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2020-02-05 11:39:21 | RECEIPT 2020-0206-102 - $22.46 - PAID | | 2019-10-21 07:54:13 | 10/21/19 EMAILED IMPACT FEE OFFICE. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-19 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-08 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2019-10-19 11:03:23 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-12-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-14 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-12 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-19 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-18 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
5 |
Status |
P |
Date |
2020-03-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-03-02 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-03-02 |
Time |
14:41 |
Sent To |
I |
|
| Notes |
| 2020-03-02 15:05:43 | NFIP REVIEW - PASSED WITH PROVISO'S: | | | | | | UPON SUBMITTAL OF THE UNDER CONSTRUCTION ELEVATION | | | CERTIFICATE - | | | | | | 1. PROVIDE THE ELEVATION OF THE GARAGE FINISHED FLOOR - | | | SEE SECTION C2 (D). | | | | | | 2. CHANGE TYPE OF FLOOD OPENINGS IN GARAGE FROM | | | NON-ENGINEERED TO ENGINEERED PER CONVERSATION WITH | | | CONTRACTOR - SEE SECTION A9 (D). | | | | | | 3. PROVIDE ICC ES EVALUATION REPORT FOR ENGINEERED | | | FLOOD OPENINGS. | | | | | | 4. REDLINE GARAGE FLOOR PLAN WITH FINISHED FLOOR | | | ELEVATION. | | | | | | NOTE: THE GREEHECK AF J60 1X VENTS SHOWN ON PLAN PAGE | | | A-1-1 ARE NOT APPROVED FLOOD VENTS. | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
4 |
Status |
P |
Date |
2020-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-03 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-02-03 |
Time |
16:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
F |
Date |
2020-02-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-01 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-02-01 |
Time |
06:49 |
Sent To |
|
|
| Notes |
| 2020-02-01 06:50:03 | PLAN REVIEW - NFIP | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SECTION C2 REQUIRES BENCHMARK UTILIZED TO BE | | | DESCRIBED IN COMMENTS SECTION. | | | | | | 2. SECTION C2 (D) REQUIRES TOP OF SLAB FOR ATTACHED | | | GARAGE TO BE STATED. THIS ELEVATION ALSO NEEDS TO BE | | | PLACED ON PLAN. | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2019-12-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-23 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-12 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2019-12-23 09:30:04 | PLAN REVIEW - NFIP | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SECTION C2 REQUIRES BENCHMARK UTILIZED TO BE | | | DESCRIBED IN COMMENTS SECTION. | | | | | | 2. SECTION C2 (D) REQUIRES TOP OF SLAB FOR ATTACHED | | | GARAGE TO BE STATED. THIS ELEVATION ALSO NEEDS TO BE | | | PLACED ON PLAN. | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2019-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-19 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-12 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2019-10-19 11:24:49 | NFIP REVIEW | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THIS PROPERTY IS LOCATED IN A FLOOD ZONE AE. AN | | | ELEVATION CERTIFICATE IS REQUIRED. | | | | | | NFIP REVIEW | | | CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16 | | | AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT | | | AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE | | | MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD | | | HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM | | | BEACH, FL. | | | ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED ON | | | NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST PALM | | | BEACH, BY ORDINANCE, NO. 4658-16, ESTABLISHED A TWO | | | FOOT FREEBOARD ABOVE THE (BFE). | | | | | | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS | | | AE WITH A BASE FLOOD ELEVATION (BFE) OF 7FT. THE CITY | | | OF WEST PALM BEACH (THROUGH ORDINANCE) REQUIRES AN | | | ADDITIONAL 24 INCHES OF FREEBOARD REQUIRING THE DESIGN | | | FLOOD ELEVATION (DFE) TO BE 9. 0 FEET. PLEASE NOTE THIS | | | INFORMATION ON YOUR PLANS. | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS | | | SITE ARE REQUIRED TO BE AT OR ABOVE 9 FEET NAVD. | | | | | | AN UNDER CONSTRUCTION (FORMBOARD) SURVEY WITH FINISHED | | | FLOOR ELEVATION IS REQUIRED. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | THIS EC MAY BE SUBMITTED FOR REVIEW PRIOR TO BUILDING | | | FINAL. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-02-04 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-02-04 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-02-04 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2020-02-04 10:51:41 | PLUMBING COMMENTS: APPROVED | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | SEE PERMIT 19100856 FOR CABANA APPROVAL |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-12-19 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-12-19 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-12-19 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2019-12-19 11:15:09 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | NFPA 99 = HEALTH CARE FACILITIES CODE | | | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 2ND REVIEW | | | PLUMBING COMMENTS: DENIED | | | 1. ADD NOTE: IRRIGATION REQUIRES SEPARATE PERMIT. ANY | | | BACKFLOW THAT IS REQUIRED BY THE FBC OR CITY ORD WILL | | | REQUIRE A SEPARATE PERMIT INSTALLED BY PLUMBING | | | CONTRACTOR ONLY. | | | 2. RE: PLAN SHEET P-1; DETAIL 5. PER WPB FBC 107.2.1, | | | PROVIDE MANUFACTURER?S SPECIFICATION AND INSTALLATION | | | GUIDE. TO BE CLEAR, ALL PLUMBING CONNECTIONS, BACKFLOW | | | PREVENTION REQUIREMENTS, TEMPERATURE OUTPUT, WORKING | | | PRESSURE, PRESSURE RATINGS, SAFETY DEVICES, WASTE | | | DISCHARGE TEMPERATURE, ELECTRICAL CHARACTERISTICS, ETC. | | | SHALL BE INCLUDED | | | INDICATE TEMPERATURE OF DISCHARGE; IF IN EXCESS OF 140 | | | DEGREES F THEN PER FBC RES P2601.1 AND FBC PL 702.5, | | | SANITARY PIPING MATERIAL RECEIVING THE DISCHARGE SHALL | | | BE RATED FOR THE TEMPERATURE OF THE DISCHARGE WASTE AND | | | SHALL CONFORM TO THE TABLES OF FBC PL 702.1, 702.2, | | | 702.3 AND 702.4 OR PROVIDE AFTERCOOLER WITH APPROPRIATE | | | BACKFLOW PREVENTION. | | | 3. SEE PLAN SHEET P-1: TO CONFORM WITH THE DEFINITION | | | OF A BUILDING DRAIN AS STATED IN FBC RES R202, PLEASE | | | NOTE THAT THERE ARE FOUR SEPARATE BUILDING DRAINS | | | SERVING THE FOLLOWING AREAS; CABANA, NORTH SIDE OF MAIN | | | HOUSE, SOUTH SIDE OF MAIN HOUSE AND GARAGE. PER FBC RES | | | P3102.1, PROVIDE A VENT TO THE EXTERIOR FOR EACH THE | | | NORTH SIDE AND THE SOUTH SIDE OF THE MAIN HOUSE. | | | 4. SHOWER IN HIS BATH IS NOT VENTED IN ACCORDANCE WITH | | | FBC RES P3108.1. INDIVIDUALLY VENT TO COMPLY WITH FBC | | | RES P3105.1. | | | 5. WATER CLOSET IN HIS BATH IS NOT VENTED. INDIVIDUALLY | | | VENT TO COMPLY WITH FBC RES P3105.1. | | | 6. BRANCH DOWNSTREAM OF WASHER SHALL BE SIZED 3? PER | | | FBC RES P3005.1.6 | | | 7. SHOWER IN HER BATH SHALL BE LABELED ON SANITARY | | | ISOMETRIC WPB FBC 107.2.1 | | | 8. LAVATORY IN ROOF BATH SHALL BE LABELED ON SANITARY | | | ISOMETRIC WPB FBC 107.2.1 | | | 9. SHOWER IN HER BATH SHALL CONNECT ABOVE THE WATER | | | CLOSET PER FBC RES P3107.3 OR BE INDIVIDUALLY VENTED | | | PER FBC RES P3105.1. PER FBC RES P3105.2, THE SHOWER | | | FIXTURE DRAIN SHALL NOT RISE VERTICALLY ABOVE THE | | | CONNECTION OF THE VENT. | | | 10. LAVATORY IN HER BATH SHALL CONNECT TO THE | | | HORIZONTAL SECTION OF THE TUB FIXTURE DRAIN PER FBC RES | | | P3108.1 AND FBC RES P3105.2, OR THE TUB SHALL BE | | | INDIVIDUALLY VENTED PER FBC RES P3105.1. | | | 11. SEE PLAN SHEET P-1: PER FBC RES 2601.1 AND FBC PL | | | 607.2, PROVIDE RECIRCULATED HOT WATER PIPING FOR ANY | | | HOT WATER DISTRIBUTION SYSTEM THAT EXCEEDS 50? FROM HOT | | | WATER SOURCE TO FARTHEST OUTLET.PER WPB FBC 107.2.1, | | | PROVIDE NOTE STATING THE SAME. | | | | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19090792 3030 WASHINGTON RD | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-23 |
Time |
05:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-10-18 |
Time |
18:42 |
Sent To |
|
|
| Notes |
| 2019-10-21 10:51:18 | PLUMBING 1ST REVIEW**DENIED** PLEASE ADD NOTE | | | IRRIGATION REQUIRES SEPARATE PERMIT. ANY BACKFLOW THAT | | | IS REQUIRED BY THE FBC OR CITY ORD WILL REQUIRE A | | | SEPARATE PERMIT INSTALLED BY PLUMBING CONTRACTOR ONLY. | | | | | | 1) PROVIDE SHOWER PAN DETAIL SHOWING MATERIAL TO BE | | | USED AND 2% SLOPE. FBCR-P 2709. | | | | | | 2) PROVIDE STEAM UNIT DRAIN DETAIL FOR HIS STEAM UNIT. | | | FBC 107.2.1 | | | | | | 3) THE CABANA BEING THAT IT HAS ITS OWN BUILDING DRAIN | | | WITH NOT PERMIT THE USE OF AN AAV AS IT WILL REQUIRE A | | | VENT TO THE OUTDOORS. FBCR-P3102.1 | | | | | | 4) PROVIDE A CODE COMPLIANT SANITARY ISOMETRIC DRAWING. | | | SEE MARK UPS ON ISO SHEET SHOWING ERRORS. THE FOLLOWING | | | COMMENTS APPLY | | | | | | A-ONLY 1 WET VENTED FIXTURE IS PERMITTED BEYOND THE | | | VENT. FBCR-P 3102.1 | | | B-CAN NOT USE THE VENT STACK ON A LOWER LEVEL WET VENT | | | FOR 2ND FLOOR BATHROOM. FBCR-P 3108.1 | | | C- SHOWER MUST BE VENTED AND DIRECTLY CONNECTED INTO | | | THE BATHROOM GROUP WET VENT. FBCR-P3108.1 | | | D- PROVIDE SIZING OF EACH SECTION OF BUILDING DRAIN IN | | | THE HIGHLIGHTED SECTIONS. FBC 107.3.5 | | | E-NO OTHER FIXTURE OTHER THEN THOSE FIND IN THE | | | BATHROOM GROUP ARE PERMITTED TO DISCHARGE INTO THE | | | BATHROOM GROUP WET VENT. | | | | | | 5) PROVIDE NOTE THAT ACCESS TO ALL AAV SHALL BE | | | PROVIDED. FBCR-P3114.5 | | | | | | 6) PROVIDE BRANCH LINE SIZE OF WASHING MACHINE. PLEASE | | | NOTE MUST BE 3? IN ORDER TO USE AAV PER THE | | | INSTALLATION MANUAL FOR ALL AAV?S. FBCR-P 3114.2 | | | | | | 7) PROVIDE STORM ISOMETRIC DRAWING. FBC 107.3.5 | | | | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH (CGASOLUTIONS) | | | [email protected]? | | | 561-248-2703 | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2020-01-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-28 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-01-28 |
Time |
11:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-12-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-14 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-12 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2019-12-14 10:48:34 | BUILDING PLAN REVIEW - ROOFING | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THIS PROPERTY IS LOCATED WITHIN A HISTORIC DISTRICT. | | | DEFERRAL OF PRODUCT APPROVALS AS NOTED ON PLAN PAGE | | | A-0.0 ARE NOT ALLOWED. SUBMIT ALL PRODUCT APPROVALS FOR | | | REVIEW. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-19 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-03 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2019-10-19 11:13:06 | BUILDING PLAN REVIEW - ROOFING | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THIS PROPERTY IS LOCATED WITHIN A HISTORIC DISTRICT. | | | DEFERRAL OF PRODUCT APPROVALS AS NOTED ON PLAN PAGE | | | A-0.0 ARE NOT ALLOWED. SUBMIT ALL PRODUCT APPROVALS FOR | | | REVIEW. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-02-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-01 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-02-01 |
Time |
06:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-12-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-14 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-12 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2019-12-31 15:28:39 | HARD COPY OF SOILS REPORT SENT TO RECORDS. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2019-10-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-15 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-08 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-02-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-02-06 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-02-06 |
Time |
15:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-10-10 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-10-08 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-10-10 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2019-10-08 15:18:44 | REQURIES SUBMITTAL OF SEPERATE LANDSCAPE PLAN OR | | | AFFIDAVIT |
|
|