| Plan Review Stops For Permit 19090546 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-11-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-11-20 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-11-20 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2019-11-20 11:02:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1) DELEGATED SUBMITTALS (TO BE SUBMITTED FOR PLAN | | | REVIEW BEFORE INSTALLATION) : | | | PROVIDE COMPLETE DESIGN, DETAILS AND SPECIFICATIONS FOR | | | THE NEW HANDRAILS SHOWN ON SHEET R-503. COMPLETE | | | DRAWINGS TO BE REVIEWED BY ENGINEER OF RECORD PRIOR TO | | | SUBMITTAL TO THIS OFFICE. SEC. 107.3.4.1 CITY | | | AMENDMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-09-23 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-09-23 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2019-09-23 18:19:33 | BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- PLANS SUBMITTED HAVE A COPY OF A DIGITAL SIGNATURE. | | | PERMIT APPLICATION AND PLANS ARE NOT A DIGITAL | | | SUBMITTAL. PLANS NEED TO HAVE THE ORIGINAL SEAL AND | | | SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED BY SEC. | | | 61G15-23.003 FAC AND CHAPTER 471 F.S. WHEN SUBMITTING | | | PLANS/DOCUMENTS FOR PUBLIC RECORDS. | | | | | | 2- THIS IS A THRESHOLD BUILDING. BASED ON THE SIZE OF | | | THE BUILDING AND THE SCOPE OF WORK SHOWN ON PLANS IT | | | WILL BE REQUIRED TO HAVE AN SPECIAL INSPECTOR. SEC. | | | 553.79(5)F.S. AND SEC. 110.8 CITY AMENDMENTS. | | | | | | A) ENGINEER OF RECORD TO PROVIDE STRUCTURAL INSPECTION | | | PLAN. | | | | | | B) CONTRACTOR TO PROVIDE SPECIAL INSPECTOR INFORMATION. | | | SEE COMMENTS ON THE THRESHOLD REVIEW. | | | PLEASE CONTACT ME FOR MORE INFORMATION REGARDING THE | | | SPECIAL INSPECTOR REQUIRED INFORMATION. | | | | | | C) PROVIDE SHORING AND BRACING PLANS FOR REVIEW. PLANS | | | TO BE REVIEWED/APPROVED BY THE ENGINEER OF RECORD PRIOR | | | TO SUBMITTAL. | | | | | | 3- DELEGATED SUBMITTALS (TO BE SUBMITTED FOR PLAN | | | REVIEW BEFORE INSTALLATION) : | | | PROVIDE COMPLETE DESIGN, DETAILS AND SPECIFICATIONS FOR | | | THE NEW HANDRAILS SHOWN ON SHEET R-503. COMPLETE | | | DRAWINGS TO BE REVIEWED BY ENGINEER OF RECORD PRIOR TO | | | SUBMITTAL TO THIS OFFICE. SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | | | | ADDED 09/24/19: | | | 4- I FORGOT TO MENTION, BUT IF THERE IS GOING TO BE | | | RE-STRIPPING OF THE PARKING SPACES, THEN SEPARATE | | | PERMIT WILL BE REQUIRED. | | | THANK YOU | | | | | | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | | COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2019-11-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-11-19 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-11-19 |
Time |
11:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-09-24 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-09-24 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2019-09-24 16:57:32 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE R.001 | | | | | | HAS A COUPLE OF NOTES FOR ELECTRICAL WORK, BUT NOT | | | SHOWN ON DRAWINGS | | | | | | 30.1, 44.10 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-10-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-10-22 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-09-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-09-24 |
Time |
11:36 |
Sent To |
P |
|
| Notes |
| 2019-09-24 11:43:57 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE INDICATIONS OF 45.5 PAINTING FIRE | | | SUPPRESSION PIPING. | | | | | | ANY WORK ON THE ANY FIRE SPRINKLER EQUIPMENT SHALL BE | | | COORDINATED WITH THE FIRE SPRINKLER CONTRACTOR. | | | | | | ALL FIRE SPRINKLER HEADS SHALL BE PROTECTED FROM ANY | | | PAINITNG MATERIAL. | | | | | | ANY PAINTED FIRE SPRINKJLER HEADS SHALL BE REPLACED | | | THROUGH SEPARATE PERMIT AND SHOP DRAWINGS. | | | | | | PLEASE REVIEW, ENSURE COMPLIANCE AND PROVIDE AN | | | APPLICABLE CONSTRUCTION NOTE OF THE RESUBMITTAL. | | | | | | | | | | | | 2) THERE ARE INDICATIONS OF 25.3 MECHAICAL PIPE AND | | | HANGERS. | | | | | | ANY WORK ON PIPE AND HANGERS INVOLVING THE FIRE | | | SPRINKLER SYSTEM SHALL BE DONE UNDER SEPARATE PERMIT | | | AND SHOP DRAWINGS BY CERTIFIED FIRE SPRINKLER | | | CONTRACTORS. | | | | | | PLEASE REVIEW, ENSURE COMPLIANCE AND PROVIDE AN | | | APPLICABLE CONSTRUCTION NOTE OF THE RESUBMITTAL. | | | | | | | | | | | | 3) THERE ARE INDICATIONS OF WORK INVOLVING EXIT ACCESS, | | | EXITS AND EXIT DISCHARGES. | | | | | | PLEASE REVIEW THESE AREAS AND PROVIDE THE ALTERNATE | | | EXITS PLANS AND ROUTES SHOULD THESE AREAS BE | | | UNACCESSIBLE TO THE PUBLIC AT ANY TIME DURING THE | | | PROJECT. | | | | | | PROVIDE APLLICABLE LIFE SAFETY PLANS WITH DETAILS. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-11-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-11-20 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-10-18 |
Time |
14:00 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-10-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-10-07 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-09-16 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2019-09-18 09:39:21 | BLDG MISC 1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-19 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-11-19 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-11-19 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2019-11-19 10:50:02 | PLUMBING COMMENTS: APPROVED W/PROVISO | | | RE: PLAN SHEET R101; SHEET NOTE 1. ACKNOWLEDGED NO | | | CHANGE IN AREA BEING DRAINED/ NO CHANGE TO FLOW OF | | | WATER ENTERING THE SYSTEM. | | | RE: PLAN SHEET R102; SHEET NOTE 1. ACKNOWLEDGED NO | | | CHANGE IN AREA BEING DRAINED/ NO CHANGE TO FLOW OF | | | WATER ENTERING THE SYSTEM. | | | SEE PLAN SHEET R-502 FOR PLANTER DRAIN DETAILS AND NEW | | | DRAIN CONNECTION DETAILS. | | | PER WPB FBC 107.2.1, A DRAWING OF RECORD SHALL BE | | | SUBMITTED OF THE PLANTER DRAINAGE SYSTEMS NOTING ALL | | | ROUTING, AS WELL AS LOCATIONS OF SUPPLEMENTAL AND | | | REUSED DRAINS INCORPORATED INTO THE SYSTEMS. DRAWING | | | (S) SHALL INCLUDE SIZES OF PIPING AND POINTS OF | | | CONNECTION TO THE EXISTING VERTICAL STORM CONDUCTOR(S). | | | SAID DRAWING(S) SHALL BE SUBMITTED AS A REVISION TO THE | | | PERMIT PLANS AND SHALL BE IN PLACE PRIOR TO FINAL | | | INSPECTION. | | | A SEPARATE PLAN AND PERMIT IS REQUIRED FOR IRRIGATION. | | | (SEE PROVISO PERTAINING TO LANDSCAPING OM PLAN SHEET | | | R-101.) | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-09-27 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-09-27 |
Time |
14:36 |
Sent To |
Z |
|
| Notes |
| 2019-09-27 14:55:14 | 1ST REVIEW: 19090385 | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1.PROVIDE STORM DRAIN ISOMETRIC INDICATE NEW AND | | | EXISTING. PER WPB AMEND TO FBC 107.3.5.1.3(13) | | | | | | 2. PROVIDE FLOOR PLAN SHOW EXACT LOCATION OF PIPING AND | | | DRAINS.PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. PROVIDE SIZING CALCULATIONS FOR NEW PLANTER DRAINS. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2019-11-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-11-20 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-11-20 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2019-11-20 11:19:01 | SPECIAL INSPECTOR: | | | ONMJ INC. | | | JOSEPH F. MINCUZZI. P.E. #38162 | | | SPECIAL INSPECTOR #952 | | | | | | LICENSED INSPECTORS | | | ERIC HERNANDEZ | | | BN3465 | | | | | | CHARLES MOCK | | | BN3682 |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2019-09-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-09-23 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-09-23 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2019-09-23 18:33:54 | THRESHOLD BUILDING COMMENTS | | | | | | 1-SEC. 110.8.1 THRESHOLD INSPECTION PLAN. THE ENFORCING | | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | | | | THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S | | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | | PLACE. | | | | | | FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' OF | | | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME' | | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | | REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, AN | | | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. FOR A JOBSITE | | | REPRESENTATIVE IS NOT AN ARCHITECT OR ENGINEER THEN | | | THEY MUST HAVE A BN LICENSE NUMBER UNDER | | | F. S. 468. | | | | | | PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR ALL | | | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 | | | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-14 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-11-14 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-11-14 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2019-11-14 16:41:38 | PROVISO: A LANDSCAPE PERMTI SHALL BE SUBMITTED FOR THE | | | RESTAURATION OF ALL PLANTING AREAS WITHIN THE GARAGE. | | | CERTIFICATE OF COMPLETION SHALL NOT BE GRANTED UNTIL | | | LANDSCAPE WORK IS COMPLETED. | | | WORK DOES NTO INCLUDE RESTRIPPING. A SEPARATE PERMIT | | | NEEDED FOR RESTRIPPING. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-10-04 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-10-04 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2019-10-04 16:44:19 | PROVISO: A LANDSCAPE PERMTI SHALL BE SUBMITTED FOR THE | | | RESTAURATION OF ALL PLANTING AREAS WITHIN THE GARAGE. | | | CERTIFICATE OF COMPLETION SHALL NOT BE GRANTED UNTIL | | | LANDSCAPE WORK IS COMPLETED. | | 2019-09-26 13:41:28 | CONTRACTOR SAID, THERE IS STRIPPING WORK INCLUDED IN | | | THIS PERMIT. SEE COPY OF E-MAIL FROM CONTRACTOR. JG. | | | | | | | | | | | | | | | MR. GOMEZ, | | | STRIPING IS LOCATED ON LEVEL P5 WORK ITEM NUMBER 45.1. | | | THE VALUE ASSOCIATED WITH STRIPING IS INCLUDED IN THE | | | TOTAL CONTRACT COST. | | | STRIPING COST $ $1,732 | | | | | | THANKS, | | | CHRISTOPHER LEWIS | | | PROJECT MANAGER | | | RESTOCON CORPORATION | | | [email protected] | | | C. (813) 802-8507 | RESTOCON.COM | | | |
|
|