Plan Review Details - Permit 19090510
| Plan Review Stops For Permit 19090510 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-11-19 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-11-19 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-11-19 |
Time |
08:46 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-10-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-10-10 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-10-10 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2019-10-10 14:20:38 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | | 805-6724 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | YOU MAY RESUBMIT PRINTABLE DOCUMENTS ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | 1.FBC B 107.2.1. ASCE 7-16 HAS NOT BEEN ADOPTED AS PART | | | OF THE FBC. WE ARE CURRENTLY USING ASCE 7-10. PLEASE | | | REVISE DRAWINGS TO REFLECT CURRENT EDITION. | | | 2.FBC B 107.2.1. PROVIDE TWO SETS OF SIGNED AND SEALED | | | DOCUMENTS VERIFYING EXISTING CONCRETE SLAB IS 6 ?? | | | THICK MINIMUM. | | | 3.FBC B 107.2.1. PROVIDE TWO SETS OF SIGNED AND SEALED | | | ENGINEERED SHOP DRAWINGS FOR THE PROPOSED LOUVERED | | | RIGID CANOPY. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-12-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-01 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-01 |
Time |
08:26 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-12-01 |
Time |
|
Rev Time |
|
| Received By |
jbrooks |
Date |
2019-11-13 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2019-11-14 15:54:07 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-10-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-10-10 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-09-13 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2019-09-16 14:12:51 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-11-15 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-11-15 |
Time |
15:32 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-09-24 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-09-24 |
Time |
13:07 |
Sent To |
B |
|
| Notes |
| 2019-09-24 13:08:00 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 09.24.2019 | | | PERMIT NO.: 19090510 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY OF | | | THE AREA SHALL BE PROVIDED. | | | | | | 2. TWO (2) COPIES OF A CURRENT AND ACCURATE SITE PLAN | | | SHALL BE PROVIDED SHOWING THE LOCATION OF THE PROPOSED | | | TRELLIS, SETBACKS FROM THE TRELLIS TO ADJACENT PROPERTY | | | LINES, ETC. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy