Plan Review Details - Permit 19090477
| Plan Review Stops For Permit 19090477 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-01-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-21 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-01-21 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-10-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-25 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-21 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2019-10-25 10:21:45 | PLAN REVIEW - BUILDING | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW EXTERIOR DOORS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 2. PROVIDE 2ND COPY OF WINDOW NOA. | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-27 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-26 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2019-09-27 09:03:49 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SOW ON PAGE A1 IS TO RENOVATE THE EXISTING KITCHEN | | | BY REMOVING AND REPLACING APPLIANCES, CABINETS AND | | | COUNTERTOPS. | | | 2. PLANS SUBMITTED ARE FOR A FULL RES REMODEL INCLUDING | | | THE RE-LOCATION OF THE EXTERIOR STAIRS TO THE INTERIOR | | | OF THE BUILDING, RE-CONFIGURING INTERIOR SPACE AND THE | | | REPLACEMENT OF MECH., ELEC., & PLUMBING SYSTEMS. | | | 3. APPLCANT SHALL INCREASE SOW TO INCLUDE ALL | | | REFERENCED WORK ON PLANS OR REMOVE ANY WORK ON PLANS | | | THAT IS NOT INCLUDED IN SOW. | | | 4. IF SOW IS INCREASED, ADJUST VALUE AND PROVIDE A | | | SIGNED COPY OF CONTRACT WITH OWNER. | | | | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-01-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-01-07 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-01-07 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-10-31 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-10-31 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-10-31 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2019-10-31 09:35:45 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PANEL SCHEDULE STATES THAT THE PANEL IS RATED FOR | | | 125 AMPS. LOAD CALCULATION STATES THE LOAD IS 141 AMPS, | | | SO THE PANEL IS NOT RATED FOR THE LOAD. PROVIDE | | | CORRECTION. NEC 408.30 (NOT CORRECTED. RISER DIAGRAM | | | SHOWS A 125 AMP DISCONNECT WITH #1 WIRE FEEDING PANEL | | | A. BASED ON LOAD CALCULATION PROVIDED, THIS DISCONNECT | | | AND WIRE WOULD BE OVERLOADED AND IS NOT SIZED PROPERLY. | | | PROVIDE CORRECTION.) | | | 2. CORRECTED. | | | 3. IS THIS A NEW SERVICE? PROVIDE CLARIFICATION. WPB | | | FBC 107.2.1 (NOT CLARIFIED.) | | | 4. IF SERVICE IS NEW OR BEING REBUILT, PROVIDE | | | AVAILABLE SHORT CIRCUIT CALCULATION FOR SERVICE | | | INCLUDING INFORMATION FROM THE POWER COMPANY STATING | | | WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE | | | SERVICE TO CONFIRM THE STATED AIC RATING OF THE SERVICE | | | EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC RE | | | E3606.3 (NOT CLARIFIED, NOT PROVIDED.) | | | 5. CORRECTED. | | | 6. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 7. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS (PANEL A AND PANEL B) TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, | | | 220, 408.30; FBC RE E3602.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-24 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-24 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2019-09-24 13:59:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PANEL SCHEDULE STATES THAT THE PANEL IS RATED FOR | | | 125 AMPS. LOAD CALCULATION STATES THE LOAD IS 141 AMPS, | | | SO THE PANEL IS NOT RATED FOR THE LOAD. PROVIDE | | | CORRECTION. NEC 408.30 | | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 3. IS THIS A NEW SERVICE? PROVIDE CLARIFICATION. WPB | | | FBC 107.2.1 | | | 4. IF SERVICE IS NEW OR BEING REBUILT, PROVIDE | | | AVAILABLE SHORT CIRCUIT CALCULATION FOR SERVICE | | | INCLUDING INFORMATION FROM THE POWER COMPANY STATING | | | WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE | | | SERVICE TO CONFIRM THE STATED AIC RATING OF THE SERVICE | | | EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC RE | | | E3606.3 | | | 5. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS | | | PERMITTED. PROVIDE CORRECTION AND/OR CLARIFICATION. WPB | | | FBC 107.2.1; NEC 230.2; FBC RE E3601.2 | | | 6. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-01-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-21 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-31 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-11-20 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-11-20 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-10-08 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-27 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-13 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2020-01-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-21 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-01-21 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-10-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-25 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-21 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-27 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-26 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2019-09-27 08:54:19 | MECHANICAL SYSTEM IS NOT PART OF SOW AS STATED ON PLAN | | | PAGE A1. IF MECHANICAL SYSTEM WILL BE INCLUDED IN THE | | | SOW, INCLUDE IN NARRATIVE ON PG A1 AND ADJUST VALUE | | | ACCORDINGLY. PROVIDE A SIGNED COPY OF CONTRACT WITH | | | OWNER. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
N |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-27 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-27 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2019-09-27 09:06:27 | PROPERTY IS LOCATED IN A FLOOD ZONE X. AN ELEVATION | | | CERTIFICATE IS NOT REQUIRED. CT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-21 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-18 |
Time |
07:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-09-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-09-20 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-09-20 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2019-09-20 11:04:36 | 1) THE ENERGY CALCULATIONS SHOW THE EF OF THE WATER | | | HEATER AS .92. AS OF 4/16/2015, THE MINIMUM EF OF WATER | | | HEATERS SHALL BE .96 PER 10 CFR SEC.430.32. | | | 2) THE SUBMITTED SANITARY RISER SHOWS NO FIXTURES. SHOW | | | PROPOSED CHANGES TO THE SANITARY SYSTEM ON THE SANITARY | | | RISER DIAGRAM. WPB AMEND. TO FBC SEC. 107.2.1. | | | 3) THE PLANS SHOW A STACKED WASHER AND DRYER. THE WATER | | | SUPPLY VALVES FOR THE WASHER SHALL BE ACCESSIBLE PER | | | 2017 FBC-PLUMBING SEC.606.3. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-11-20 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-11-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-11-20 |
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |