Plan Review Details - Permit 19090425
| Plan Review Stops For Permit 19090425 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-10-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-10-17 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-10-17 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2019-10-17 16:00:13 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | 2ND BLDG. REVIEW APPRIOVED WITH PROVISO. | | | | | | FBC B 107.2.1 AT TIME OF INSPECTION PROVIDE: | | | | | | APPROVED SIGNED/SEALED DETAILS/SPECIFICATIONS FOR THE | | | W12X53 PILE DRIVEN STEEL FOUNDATION INCLUDING COLUMN TO | | | PILE CONNECTIONS; A (WELD PROCEDURE SPECIFICATION) AND | | | (WELDER QUALIFICATION RECORDS) ARE ALSO REQUIRED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-10-10 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-10-10 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-10-10 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2019-10-10 16:56:24 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | PLEASE PROVIDE FOOTING DETAILS INCLUDING SPECIFICATIONS | | | FOR: CONCRETE, DIMENSIONS/LOCATIONS, REINFORCING STEEL, | | | BASE PLATE ANCHORING. | | | | | | NOTE: | | | A WELD PROCEDURE SPECIFICATION AND WELDER QUALIFICATION | | | RECORDS WILL BE REQUIRED AT TIME OF INSPECTIONS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-10-10 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-10-10 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-09-12 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2019-10-08 09:20:06 | 10/2 WAS PULLED FROM REVIEW, ROUTED BACK TO ZONING | | | | | | | | 2019-09-13 13:58:10 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-10-09 |
|
|
Cont ID |
|
| Sent By |
rfalcone |
Date |
2019-10-09 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
rfalcone |
Date |
2019-10-09 |
Time |
11:39 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-09-16 |
|
|
Cont ID |
|
| Sent By |
rfalcone |
Date |
2019-09-16 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rfalcone |
Date |
2019-09-16 |
Time |
14:16 |
Sent To |
B |
|
| Notes |
| 2019-09-16 14:18:02 | 09/16/19 FAILED. | | | | | | PLEASE PROVIDE A RECENT SURVEY OF THE SUBJECT SITE AND | | | INCLUDE PROVIDED SETBACKS FOR THE PROPOSED PAVILION | | | SHED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: (561) 822-1442 | | | E-MAIL: [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |