Plan Review Details - Permit 19090365
Plan Review Stops For Permit 19090365
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-11-18 Cont ID  
Sent By cthroop Date 2019-11-18 Time 10:34 Rev Time 0.00
Received By cthroop Date 2019-11-18 Time 09:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-10-02 Cont ID  
Sent By cthroop Date 2019-10-02 Time 10:55 Rev Time 0.00
Received By cthroop Date 2019-10-01 Time 17:14 Sent To  
Notes
2019-10-02 11:00:03BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROPOSED WORK WILL INCREASE THE HABITABLE SPACE.
 PALM BEACH COUNTY IMPACT FEES MAY APPLY.
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 2. NOTE ON FLOOR PLAN STATES NEW 53 X 50 SH IMPACT
 WINDOW HAS BEEN INSTALLED.
  
 2A. PROVIDE PRODUCT APPORVALS FOR THIS WINDOW. DESIGNER
 TO REVIEW AND APPROVE.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW SUBMITTALS.
  
 2B. 4 X FEE MAY BE ASSESSED FOR THE VALUE OF WORK
 PERFORMED WITHOUT PERMIT.
 F.S. 553.80 (2) (B)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-11-05 Cont ID  
Sent By jpearson Date 2019-11-05 Time 15:42 Rev Time 0.00
Received By jpearson Date 2019-11-05 Time 15:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-10-01 Cont ID  
Sent By jpearson Date 2019-10-01 Time 15:29 Rev Time 0.00
Received By jpearson Date 2019-10-01 Time 13:02 Sent To  
Notes
2019-10-01 15:04:03CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PLAN SHOWS NEW 125 AMP PANEL. WHERE IS THIS PANEL
 FED FROM? PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW
 INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230,
 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1,
 E3609.3; WPB FBC 107.2.1
 2. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE THE
 NEW PANEL IS FED FROM, INCLUDE EXISTING AND NEW LOADS
 TO CONFIRM CAPACITY OF SERVICE IS ADEQUATE. THE 3 WATTS
 PER SQUARE FOOT IS NOT INCLUDED IN THE CALCULATION
 PROVIDED. NEC 215.2, 220, 408.30; FBC RE E3602.2
 3. BASED ON COMMENT 2, THE 125 AMP PANEL IS OVERLOADED.
 PROVIDE CORRECTION. NEC 408.30; BC RE E3706.1
 4. FLOOR PLAN SHOWS AN AC LOCATED DIRECTLY IN FRONT OF
 THE ELECTRICAL SERVICE. PROVIDE CORRECTION TO MAINTAIN
 CLEARANCE PER CODE. NEC 110.26; FBC RE E3405
 5. PLAN IS NOT CLEAR ON THE EXISTING ELECTRICAL
 SSERVICE. IF A NEW SERVICE IS TO BE INSTALLED, PROVIDE
 AVAILABLE SHORT CIRCUIT CALCULATION FOR SERVICE
 INCLUDING INFORMATION FROM THE POWER COMPANY STATING
 WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE
 SERVICE TO CONFIRM THE STATED AIC RATING OF THE SERVICE
 EQUIPMENT IS ADEQUATE. PROVIDE AIC RATING OF ELECTRICAL
 SERVICE EQUIPMENT. NEC 110.3, 110.9, 110.10; FBC RE
 E3606.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-11-18 Cont ID  
Sent By cthroop Date 2019-11-18 Time 10:35 Rev Time 0.00
Received By cthroop Date 2019-10-22 Time 14:17 Sent To  
Notes
2019-10-23 14:17:38R09

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-10-02 Cont ID  
Sent By cthroop Date 2019-10-02 Time 11:23 Rev Time 0.00
Received By cthroop Date 2019-09-11 Time 14:24 Sent To  
Notes
2019-09-12 14:24:57R04

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-11-18 Cont ID  
Sent By cthroop Date 2019-11-18 Time 10:34 Rev Time 0.00
Received By cthroop Date 2019-11-18 Time 09:33 Sent To  
Notes
2019-11-18 10:35:10MU-2019-031249-0000. CT

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-10-02 Cont ID  
Sent By cthroop Date 2019-10-02 Time 10:53 Rev Time 0.00
Received By cthroop Date 2019-10-01 Time 17:14 Sent To  
Notes
2019-10-02 10:55:37BUILDING PLAN REVIEW - IMPACT FEES
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROPOSED WORK WILL INCREASE THE HABITABLE SPACE.
 PALM BEACH COUNTY IMPACT FEES MAY APPLY.
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-11-18 Cont ID  
Sent By cthroop Date 2019-11-18 Time 10:34 Rev Time 0.00
Received By cthroop Date 2019-11-18 Time 09:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-10-02 Cont ID  
Sent By cthroop Date 2019-10-02 Time 08:29 Rev Time 0.00
Received By cthroop Date 2019-10-01 Time 17:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-11-08 Cont ID  
Sent By gjohnson Date 2019-11-08 Time 10:19 Rev Time 0.00
Received By gjohnson Date 2019-11-08 Time 10:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-09-24 Cont ID  
Sent By lcrespo Date 2019-09-24 Time 14:58 Rev Time 0.00
Received By lcrespo Date 2019-09-24 Time 14:58 Sent To  
Notes
2019-09-24 14:58:5109/24/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2019-10-02 Cont ID  
Sent By cthroop Date 2019-10-02 Time 08:29 Rev Time 0.00
Received By cthroop Date 2019-10-01 Time 17:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2019-10-24 Cont ID  
Sent By rfalcone Date 2019-10-24 Time 16:44 Rev Time 0.00
Received By rfalcone Date 2019-10-24 Time 16:44 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2019-09-19 Time   Rev Time 0.00
Received By rfalcone Date 2019-09-19 Time 15:50 Sent To  
Notes
2019-09-19 15:52:1109/19/19 - FAILED.
  
 PLEASE PROVIDE A SURVEY OF THE SUBJECT SITE.
  
 RACHEL FALCONE, ASSOCIATE PLANNER
 (561) 822-1442
 [email protected]