Plan Review Details - Permit 19090106
Plan Review Stops For Permit 19090106
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-12-02 Cont ID  
Sent By shill Date 2019-12-02 Time 12:50 Rev Time 0.00
Received By dbattles Date 2019-12-02 Time 12:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-09-17 Cont ID  
Sent By shill Date 2019-09-17 Time 17:21 Rev Time 0.00
Received By shill Date 2019-09-17 Time 17:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-12-04 Cont ID  
Sent By jpearson Date 2019-12-04 Time 09:30 Rev Time 0.00
Received By jleahy Date 2019-12-04 Time 09:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-09-16 Cont ID  
Sent By jpearson Date 2019-09-16 Time 15:21 Rev Time 0.00
Received By jpearson Date 2019-09-16 Time 15:21 Sent To  
Notes
2019-09-16 15:21:49CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. WIRE AND SERVICE EQUIPMENT IS NOT SIZED TO HANDLE
 THE LOAD. PROVIDE CORRECTIONS. NEC 220, 215.2, 215.5,
 408.30, 408.36, 310.15(B)(16), 240.4
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-11-23 Cont ID  
Sent By bwoods Date 2019-11-23 Time   Rev Time 0.00
Received By bwoods Date 2019-11-23 Time   Sent To E
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-10-16 Cont ID  
Sent By bwoods Date 2019-10-16 Time   Rev Time 0.00
Received By bwoods Date 2019-10-16 Time   Sent To I
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2019-09-24 Cont ID  
Sent By jesmith Date 2019-09-17 Time 15:38 Rev Time 0.00
Received By jesmith Date 2019-09-17 Time 15:32 Sent To  
Notes
2019-09-17 15:38:19GAS COMMENTS: NOT REQUIRED
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-12-04 Cont ID  
Sent By jleahy Date 2019-12-04 Time 09:31 Rev Time 0.00
Received By jleahy Date 2019-11-08 Time 15:54 Sent To  
Notes
2019-11-12 15:54:47B19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-10-16 Cont ID  
Sent By cpuell Date 2019-10-16 Time 15:02 Rev Time 0.00
Received By cpuell Date 2019-09-06 Time 08:41 Sent To  
Notes
2019-09-09 08:48:00B04

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-09-24 Cont ID  
Sent By jesmith Date 2019-09-17 Time 15:40 Rev Time 0.00
Received By jesmith Date 2019-09-17 Time 15:38 Sent To  
Notes
2019-09-17 15:40:35PLUMBING COMMENTS: APPROVED
 MASTER PERMIT 17110126
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved