Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2019-12-10 Cont ID  
Sent By jwitmer Date 2019-12-10 Time 07:52 Rev Time 0.00
Received By jwitmer Date 2019-12-10 Time 07:52 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2019-10-21 Cont ID  
Sent By jwitmer Date 2019-10-21 Time 14:03 Rev Time 0.00
Received By jwitmer Date 2019-10-21 Time 13:34 Sent To  
Notes
2019-10-21 14:02:56BUILT IN 1987.
 ASBESTOS COMMERCIAL: PLEASE PROVIDE A SIGNED
 ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON LETTERHEAD,
 STATING THAT THE INSTRUCTIONS ON THE WEBSITE OF
 ASBESTOS PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF
 HEALTH PALM BEACH COUNTY WILL BE FOLLOWED AND THAT
 NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL
 INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE
 FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/_DOCUMENTS/ASBESTOS-
 NOTIFICATION-FORM-PBC-FILLABLE-UPDATE-07-30-2015.PDF
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-12-18 Cont ID  
Sent By shill Date 2019-12-18 Time 14:17 Rev Time 0.00
Received By shill Date 2019-12-18 Time 14:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-12-10 Cont ID  
Sent By jwitmer Date 2019-12-10 Time 08:21 Rev Time 0.00
Received By jwitmer Date 2019-12-10 Time 08:00 Sent To  
Notes
2019-12-10 08:18:552017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19081491
 ADD: 250 S AUSTRALIAN AVE. SUITE # 1504
 CONT:ADVANCED COMMERCIAL INTERIORS, INC.
 TEL: 954-580-6658
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. DEC. 10TH/ 2019
 ACTION: DENIED
  
  
 ***************4X FEE / NOTICE!!!!! FLORIDA STATUTE
 553.80(2)(B) *****************
  
  
  
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  
 1) 2ND REQUEST. SAME COMMENT. 2017 EXISTING BUILDING
 CODE. 801.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING.
 PLEASE NOTE ON SHEET A1.1.1 PLEASE SHOW COMPLIANCE WITH
 THE 2017 FBC-ACCESSIBILITY CODE SECTION CODE 404.2.4
 MANEUVERING CLEARANCES. DOORS. MINIMUM MANEUVERING
 CLEARANCES AT DOORS AND GATES SHALL COMPLY WITH
 404.2.4. MANEUVERING CLEARANCES SHALL EXTEND THE FULL
 WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE FOR
 SIDE CLEARANCE AND FIGURE 404.2.4.1(A) 18 INCHES ON THE
 PULL SIDE OF THE DOOR LATCH SIDE FOR THE FOLLOWING
 DOORS:
  
 1A) DOOR 1505 NO, DOES NOT SHOW COMPLIANCE WITH THE
 2017 FBC-ACCESSIBILITY CODE 404.2.4.1(A) REQUIRING 18
 INCHES ON THE PULL SIDE OF THE LATCH SIDE OF THE DOOR.
  
 1B) DOOR 1513 NO, DOES NOT SHOW COMPLIANCE WITH THE
 2017 FBC-ACCESSIBILITY CODE 404.2.4.1(A) REQUIRING 18
 INCHES ON THE PULL SIDE OF THE LATCH SIDE OF THE DOOR.
  
 1C) DOOR 1514 NO, DOES NOT SHOW COMPLIANCE WITH THE
 2017 FBC-ACCESSIBILITY CODE 404.2.4.1(A) REQUIRING 18
 INCHES ON THE PULL SIDE OF THE LATCH SIDE OF THE DOOR.
  
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-10-21 Cont ID  
Sent By jwitmer Date 2019-10-21 Time 14:01 Rev Time 0.00
Received By jwitmer Date 2019-10-21 Time 13:34 Sent To  
Notes
2019-10-21 14:01:222017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19081491
 ADD: 250 S AUSTRALIAN AVE. SUITE # 1504
 CONT: CHANDLIER CONSTRUCTION CO.
 TEL: 561-791-6934
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. OCT. 21/ 2019
 ACTION: DENIED
  
 1) 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL
 NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING. PLEASE NOTE ON SHEET
 A1.1.1 PLEASE SHOW COMPLIANCE WITH THE 2017
 FBC-ACCESSIBILITY CODE SECTION CODE 404.2.4 MANEUVERING
 CLEARANCES. DOORS. MINIMUM MANEUVERING CLEARANCES AT
 DOORS AND GATES SHALL COMPLY WITH 404.2.4. MANEUVERING
 CLEARANCES SHALL EXTEND THE FULL WIDTH OF THE DOORWAY
 AND THE REQUIRED LATCH SIDE FOR SIDE CLEARANCE AND
 FIGURE 404.2.4.1(A) 18 INCHES ON THE PULL SIDE OF THE
 DOOR LATCH SIDE FOR THE FOLLOWING DOORS:
 1A) DOOR 1505
 1B) DOOR 1513
 1C) DOOR 1514
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-12-13 Cont ID  
Sent By jleahy Date 2019-12-13 Time 14:42 Rev Time 0.00
Received By jleahy Date 2019-12-13 Time 14:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-10-22 Cont ID  
Sent By jpearson Date 2019-10-22 Time 07:06 Rev Time 0.00
Received By jpearson Date 2019-10-22 Time 06:51 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2019-10-22 Cont ID  
Sent By jpearson Date 2019-10-22 Time 07:06 Rev Time 0.00
Received By jpearson Date 2019-10-22 Time 07:06 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-11-22 Cont ID  
Sent By pleduc Date 2019-11-22 Time   Rev Time 0.00
Received By pleduc Date 2019-11-22 Time 13:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-09-20 Cont ID  
Sent By J.Walker Date 2019-09-20 Time   Rev Time 0.00
Received By jwalker Date 2019-09-20 Time 14:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-12-18 Cont ID  
Sent By shill Date 2019-12-18 Time 14:17 Rev Time 0.00
Received By shill Date 2019-12-17 Time 12:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-12-13 Cont ID  
Sent By jleahy Date 2019-12-13 Time 14:42 Rev Time 0.00
Received By jleahy Date 2019-11-21 Time 15:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-10-30 Cont ID  
Sent By shill Date 2019-10-30 Time 07:58 Rev Time 0.00
Received By shill Date 2019-09-16 Time 08:29 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-10-21 Cont ID  
Sent By jwitmer Date 2019-10-21 Time 14:03 Rev Time 0.00
Received By jwitmer Date 2019-10-21 Time 13:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-10-16 Cont ID  
Sent By ccole Date 2019-10-16 Time 08:20 Rev Time 0.00
Received By ccole Date 2019-10-16 Time 07:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2019-10-10 Cont ID  
Sent By tklarge Date 2019-10-10 Time 10:24 Rev Time 0.00
Received By tklarge Date 2019-10-10 Time 10:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-12-18 Cont ID  
Sent By shill Date 2019-12-18 Time 14:17 Rev Time 0.00
Received By shill Date 2019-12-18 Time 14:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-12-13 Cont ID  
Sent By shill Date 2019-12-13 Time 09:44 Rev Time 0.00
Received By shill Date 2019-12-13 Time 09:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-10-22 Cont ID  
Sent By jpearson Date 2019-10-22 Time 07:01 Rev Time 0.00
Received By jpearson Date 2019-10-22 Time 07:01 Sent To  
Notes
2019-10-22 07:01:33ELECTRICAL SHEETS: PER THE WPB AMENDMENTS TO THE FBC,
 EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND SEALED
 BY THE PERSON RESPONSIBLE FOR THE DESIGN. A DIGITAL
 PLAN REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD
 PARTY VERIFICATION. SELF-CERTIFICATION IS NOT
 ACCEPTABLE FOR ENGINEERS. PROVIDE CORRECTION FOR SHEET
 E0.1. WPB FBC 107.1; FS 471/481
2019-10-21 14:10:53ARCHITECTURAL SHEETS ARE NOT OPENING UP FOR 3RD PARTY
 VARIFICATION. ARCHITECT DIGITAL SIGNING & SEALING
 PLANS. 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. JAMES A.
 WITMER BN, PX, CBO/ SENIOR COMMERCIAL COMBINATION PLANS
 EXAMINER
  
  

Review Stop Z ZONING
Rev No 1 Status N Date 2019-10-30 Cont ID  
Sent By aaponte Date 2019-10-30 Time 07:58 Rev Time 0.00
Received By shill Date 2019-10-30 Time 07:58 Sent To  
Notes
***NONE***