Plan Review Details - Permit 19081475
Plan Review Stops For Permit 19081475
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2019-09-30 Cont ID  
Sent By jwitmer Date 2019-09-30 Time 07:25 Rev Time 0.00
Received By jwitmer Date 2019-09-30 Time 07:24 Sent To  
Notes
2019-09-30 07:25:28BUILT IN 2008.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-10-10 Cont ID  
Sent By pvalenti Date 2019-10-10 Time 15:07 Rev Time 0.00
Received By pvalenti Date 2019-10-10 Time 13:55 Sent To  
Notes
2019-10-10 15:11:10PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 2ND BUILDING REVIEW APPROVED WITH PROVISO:
  
 AT TIME OF INSPECTION, PROVIDE DESIGNER OF RECORD
 REVIEW STAMPED/SIGNED PRODUCT APPROVALS/SHOP DRAWINGS
 FOR DOORS, WINDOWS & GLAZING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-09-30 Cont ID  
Sent By jwitmer Date 2019-09-30 Time 07:22 Rev Time 0.00
Received By jwitmer Date 2019-09-30 Time 05:46 Sent To  
Notes
2019-09-30 07:23:572017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19081475
 ADD: 1641 WORTHINGTON RD. SUITE: 200
 CONT: ANDERSON-MOORE CONSTRUCTION CORP.
 TEL: 561-348-4805
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. SEPT. 30/ 2019
 ACTION: DENIED
  
 1) THE LIFE SAFETY PLAN AND SHEET A1.1 SHOWS THE
 OVERALL DIAGONAL DISTANCE OF SUITE # 200 BUT NOT THE
 1/3RD THE DISTANCE BETWEEN THE EXIT DOORS. PLEASE
 PROVIDE THE DISTANCE BETWEEN THE MAIN ENTRY DOOR (200)
 AND DOOR # 213.
 PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-B SECTION
 1007.1.1EXCEPTION # 2. WHERE A BUILDING IS EQUIPPED
 THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN
 ACCORDANCE WITH 903.3.1.1. THE SEPARATION DISTANCE
 SHALL NOT BE LESS THAN 1/3 THE OVERALL DIAGONAL
 DIMENSION OF THE AREA SERVED.
  
 2) THE PROPOSED NEWLY RECONFIGURED FORMED TENANT SPACE
 JUST BENEATH ROOM 214 ALSO IS MISSING THE OVERALL
 DIAGONAL DIMENSION AND THE DIAGONAL DISTANCE BETWEEN
 THE EXISTING EXIT ACCESS DOOR AND THE PROPOSED OPENING
 213 A.
 PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-B SECTION
 1007.1.1EXCEPTION # 2. WHERE A BUILDING IS EQUIPPED
 THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN
 ACCORDANCE WITH 903.3.1.1. THE SEPARATION DISTANCE
 SHALL NOT BE LESS THAN 1/3 THE OVERALL DIAGONAL
 DIMENSION OF THE AREA SERVED.
  
 3) DISCREPANCY IN THE PLANS SHEET A1.1 THE NEW PROPOSED
 FRONT ENTRY DOOR IS DESIGNATED WITH A DOOR TAG 200.
 SHEET A2.0 IN THE DOOR SCHEDULE DOOR # 200 THE DOOR IS
 IDENTIFIED AS A 1 ? INCH WOOD DOOR IDENTIFIED AS DOOR
 TYPE E. ON THE SAME SHEET IN THE DOOR ELEVATIONS IS
 WHERE THE DISCREPANCY OCCURS. THE WORDING BENEATH THE
 PICTURE INDICATES A 45 MINUTE RATED SOLID CORE WOOD
 DOOR BUT DEPICTED IS A GLAZED DOOR.
 DISCREPANCY, PLEASE PROVIDE ADDITIONAL INFORMATION
 107.2.1.2. PLEASE REVIEW OPENING PROTECTIVES UNDER
 FBC-B TABLE 716.5 AND &16.6.
  
 4) SHEET A2.0 DOORS IDENTIFIED AS DOOR TYPE A INDICATES
 THEY ARE TO BE RE-USED AND WITH A SIDE LITE. NEITHER
 THE DOOR SCHEDULE NOR DOOR ELEVATIONS INDICATE WHAT
 TYPE OF GLAZING IS IN THE SIDE-LITE.
 PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-B FOR
 HAZARDOUS LOCATIONS, SECTION 2406.4.2 GLAZING ADJACENT
 TO DOORS. 2017 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATIVE CODE
 104.9.1 USED MATERIALS. THE USE OF USED, RECYCLED OR
 RECLAIMED MATERIALS WHICH MEETS THE REQUIREMENTS OF
 THIS CODE FOR NEW MATERIALS IS PERMITTED.
  
 5) THE SAME QUESTION AS THE PLUMBING PLANS EXAMINER,
 THE DEMOLITION PLAN AD1.1 DOES NOT SHOW THE BREAK ROOM
 CABINETRY NOR SINK NOR IS THERE ANY NOTES UNDER THE
 HEADING OF DEMOLITION KEYNOTES OR PLUMBING DEMOLITION
 NOTES? ADDITIONAL INFORMATION IS REQUIRED 107.2.1.2 FOR
 COMPLIANCE WITH:
  
 5A) 2017 FBC-ACCESSIBILITY CODE 606.2 CLEAR FLOOR
 SPACE. A CLEAR FLOOR SPACE COMPLYING WITH 305,
 POSITIONED FOR A FORWARD APPROACH, AND KNEE AND TOE
 CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED.
 EXCEPTIONS:
 1.A PARALLEL APPROACH COMPLYING WITH 305 SHALL BE
 PERMITTED TO A KITCHEN SINK, IN A SPACE WHERE A COOK
 TOP OR CONVENTIONAL RANGE IS NOT PROVIDED, AND TO WET
 BARS.
  
 5B) 2017 FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 5C) WORK SURFACES.2017 FBC-ACCESSIBILITY CODE 902.3
 HEIGHT. THE TOPS OF WORK SURFACES SHALL BE 28 INCHES
 MINIMUM AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-09-17 Cont ID  
Sent By jleahy Date 2019-09-17 Time 15:03 Rev Time 0.00
Received By jleahy Date 2019-09-17 Time 15:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-09-06 Cont ID  
Sent By pleduc Date 2019-09-06 Time   Rev Time 0.00
Received By pleduc Date 2019-09-06 Time 15:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-10-10 Cont ID  
Sent By lmarchan Date 2019-10-10 Time 16:39 Rev Time 0.00
Received By lmarchan Date 2019-10-07 Time 13:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-09-30 Time   Rev Time 0.00
Received By lmarchan Date 2019-09-05 Time 16:47 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-09-30 Cont ID  
Sent By jwitmer Date 2019-09-30 Time 07:24 Rev Time  
Received By jwitmer Date 2019-09-30 Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-10-10 Cont ID  
Sent By ccole Date 2019-10-10 Time 10:31 Rev Time 0.00
Received By ccole Date 2019-10-10 Time 10:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-09-19 Cont ID  
Sent By ccole Date 2019-09-19 Time 17:17 Rev Time 0.00
Received By ccole Date 2019-09-19 Time 17:17 Sent To  
Notes
2019-09-19 17:22:301ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19081475
 9/19/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M2.2: REFER TO SECTION 602.1 FBC M: PLENUMS
 SHALL BE LIMITED TO ONE FIRE AREA. AIR SYSTEMS SHALL BE
 DUCTED FROM THE BOUNDARY OF THE FIRE AREA SERVED
 DIRECTLY TO THE AIR-HANDLING EQUIPMENT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2019-10-10 Cont ID  
Sent By tklarge Date 2019-10-10 Time 09:41 Rev Time 0.00
Received By tklarge Date 2019-10-10 Time 09:07 Sent To  
Notes
2019-10-10 09:41:59EXISTING ACCESSIBLE BREAK ROOM SINK TO REMAIN. NO NEW
 PLUMBING WORK BEING DONE. TKL.

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-09-09 Cont ID  
Sent By thunt Date 2019-09-09 Time 07:52 Rev Time 0.00
Received By rmcdouga Date 2019-09-09 Time 07:52 Sent To  
Notes
2019-09-09 07:53:47PLUMBING 1ST REVIEW**DENIED**
  
 1) THE BREAK ROOM SINK (202) YOUR CLAIMING IS EXISTING
 BUT NOT SHOWING IT ON DEMO PLAN. PLEASE CLARIFY. FBC
 107.2.1
 2) ADD NOTE ON PLAN THAT EXISTING BREAK ROOM SINK WILL
 MEET FLORIDA ACCESSIBILITY SHOWING CLEAR FLOOR SPACE
 AND MAX COUNTER TOP HEIGHT AS 34?. FBC-ACC 804.3.1,
 804.3.2
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH (CGA SOLUTIONS)
 [email protected]
 561-248-2703
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-10-10 Cont ID  
Sent By shill Date 2019-10-10 Time 08:25 Rev Time 0.00
Received By shill Date 2019-10-10 Time 08:25 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2019-10-03 Cont ID  
Sent By shill Date 2019-10-03 Time 07:17 Rev Time 0.00
Received By shill Date 2019-10-03 Time 07:17 Sent To  
Notes
2019-09-30 07:27:57ARCHITECTURAL SHEETS REVIEWED BY J. W. ELECTRONIC
 SIGNATURES, OK.

Review Stop Z ZONING
Rev No 2 Status P Date 2019-10-10 Cont ID  
Sent By llouie Date 2019-10-10 Time   Rev Time 0.00
Received By llouie Date 2019-10-10 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-09-13 Cont ID  
Sent By llouie Date 2019-09-13 Time   Rev Time  
Received By llouie Date 2019-09-13 Time   Sent To  
Notes
***NONE***