Plan Review Details - Permit 19081362
| Plan Review Stops For Permit 19081362 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-03-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-03-12 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-03-12 |
Time |
13:04 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-09-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-09-20 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-09-20 |
Time |
12:05 |
Sent To |
FIRE |
|
| Notes |
| 2019-09-20 12:10:57 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NEED AN ELECTRICAL PERMIT FOR THE 120 VOLT WORK | | | | | | VALUE LOOKS LOW, PLEASE SUBMIT A SIGNED CONTRACT FOR | | | THE WORK INVOLVED | | | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. | | | . | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-03-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-03-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-03-04 |
Time |
14:18 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-09-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-09-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-09-23 |
Time |
13:34 |
Sent To |
I |
|
| Notes |
| 2019-09-23 13:39:48 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE IS NO INDICATION OF AN ENGINEER'S SEAL AND | | | SIGNATURE. | | | | | | PER FLORIDA STATUTE 61G15-32.008 DESIGN OF FIRE ALARMS | | | AND DETECTION SYSTEMS, THE AMOUNT THRESHOLD FOR THIS | | | DESIGN EXCEEDS THE REQUIREMENT FOR A EOR OF THE | | | BUILDING CODE. | | | | | | PLEASE PROVIDE THE APPLICABLE SIGNATURE AND SEA OF AN | | | EOR. | | | | | | | | | | | | 2) THERE ARE SD INDICAED IN THE CENTER OF THE ROOMS. | | | THE MANUFACTURERS SPEC DO NOT INDICATE ANY MOUNTING | | | INFORMATION. | | | | | | PLEASE ENSURE THAT THEY ARE NOT MOUNTED OVER CEILING | | | FANS OR WITHIN THE CODE REQUIRMENTS FOR A/C VENTS. | | | | | | PLEASE PROVIDE MOUNTING DETAILS AND INDICATE ANY | | | CEILING FANS AND A/C VENTS. | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-03-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-03-02 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2020-03-03 14:20:03 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-09-24 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-08-27 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2019-08-27 15:01:12 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2020-03-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-03-17 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-03-17 |
Time |
14:40 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-09-20 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-09-20 |
Time |
08:25 |
Sent To |
E |
|
| Notes |
| 2019-09-20 08:31:37 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19081362 | | | 9/20/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE VALUE OF THE PROJECT EXCEEDS $5000 WHICH | | | REQUIRES A FL. LICENSED ENGINEER TO SIGN AND SEAL THE | | | PLANS- SECTION 105.3.1.2 WPB. | | | | | | 2) PLEASE SHOW THE LOCATIONS OF DUCT SMOKE DETECTORS ON | | | THE PLAN IF APPLICABLE- SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|