Plan Review Details - Permit 19081341
Plan Review Stops For Permit 19081341
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-23 Cont ID  
Sent By rmcdouga Date 2019-09-23 Time 11:19 Rev Time 0.00
Received By rmcdouga Date 2019-09-23 Time 11:19 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-09-11 Cont ID  
Sent By rmcdouga Date 2019-09-11 Time 08:15 Rev Time 0.00
Received By rmcdouga Date 2019-09-11 Time 07:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-09-19 Cont ID  
Sent By jleahy Date 2019-09-19 Time 10:49 Rev Time 0.00
Received By jleahy Date 2019-09-19 Time 10:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-09-13 Cont ID  
Sent By jleahy Date 2019-09-13 Time 14:27 Rev Time 0.00
Received By jleahy Date 2019-09-13 Time 14:27 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2019-09-05 Cont ID  
Sent By lcrespo Date 2019-09-05 Time 17:06 Rev Time 0.00
Received By lcrespo Date 2019-09-05 Time 17:06 Sent To  
Notes
2019-09-05 17:07:24GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2019-09-05 Cont ID  
Sent By lcrespo Date 2019-09-05 Time 17:12 Rev Time 0.00
Received By lcrespo Date 2019-09-05 Time 17:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-09-23 Cont ID  
Sent By rmcdouga Date 2019-09-23 Time 11:20 Rev Time 0.00
Received By rmcdouga Date 2019-09-17 Time 13:53 Sent To  
Notes
2019-09-18 13:53:38RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-09-13 Cont ID  
Sent By jleahy Date 2019-09-13 Time 14:27 Rev Time 0.00
Received By jleahy Date 2019-08-27 Time 14:44 Sent To  
Notes
2019-08-27 14:45:03ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-09-19 Cont ID  
Sent By lcrespo Date 2019-09-19 Time 16:02 Rev Time 0.00
Received By lcrespo Date 2019-09-19 Time 16:02 Sent To  
Notes
2019-09-19 16:03:219/19/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-09-05 Cont ID  
Sent By lcrespo Date 2019-09-05 Time 17:07 Rev Time 0.00
Received By lcrespo Date 2019-09-05 Time 17:07 Sent To  
Notes
2019-09-05 17:08:1209/05/2019 1ST PLUMBING/POOL REVIEW **DENIED** WITH
 COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. A REDUCED PRESSURE ZONE BACKFLOW DEVICE WILL BE
 REQUIRED AT THE WATER METER PER THE CITY OF WEST PALM
 CROSS CONNECTION CONTROL MANUAL AND A PVB FOR POOL FILL
 PER THE CITY OF WEST PALM BEACH ORD #2853-95 AND 2017
 FBC-PLUMBING SEC.608.1. A PERMIT REQUIRED BY A LICENSED
 CONTRACTOR AND MUST BE CERTIFIED BY UTILITIES PRIOR TO
 FINAL INSPECTION SO PLEASE CONTACT CITY OF WPB
 UTILITIES AT 561-822-2240 FOR FURTHER DIRECTIONS.
  
 2. SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE
 MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM
 ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN
 DETERMINING THE MAXIMUM SYSTEM FLOW RATE PER
 ANSI/APSP/ICC 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013
 EDITION ADDRESSES FLOW RATE IN GALLONS PER MINUTE
 (GPM). IT REQUIRES THAT THE MAXIMUM SYSTEM FLOW RATE
 DOES NOT EXCEED THE LISTED MAXIMUM FLOW RATE OF THE
 SUCTION OUTLET FITTING ASSEMBLY (DRAIN COVER). THE TDH
 CALCULATIONS MUST INCLUDE ALL OF THE SYSTEM COMPONENTS
 INCLUDING SUCTION AND RETURN PIPING, FITTINGS, VALVES,
 HEATER, FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS
 EXCEPT THE PUMP.
  
 3. IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS
 SPECIFIC TO THE PUMP BEING INSTALLED ON THIS POOL. THIS
 IS NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE
 TDH CALCULATIONS. ANSI/APSP/ICC 7 - 2013 SECS. 4.4.9,
 4.4.9.1.
  
 4. PLEASE PROVIDE DOCUMENT GAS AND SPA HEATERS THAT
 SHOW IT HAVING A MINIMUM THERMAL EFFICIENCY OF 82 % FOR
 HEATERS MANUFACTURED ON OR AFTER APRIL 16, 2013, WHEN
 TESTED IN ACCORDANCE WITH ANSI Z 21.56. POOL HEATERS
 FIRED BY NATURAL OR LP GAS SHALL NOT HAVE CONTINUOUSLY
 BURNING PILOT LIGHTS. 2017 FBC-ENERGY ? SEC. R403.10.4.
  
 5. HEATED SWIMMING POOLS AND IN GROUND PERMANENTLY
 INSTALLED SPAS SHALL BE EQUIPPED WITH A VAPOR-RETARDANT
 COVER ON OR AT THE WATER SURFACE OR A LIQUID COVER OR
 OTHER MEANS PROVEN TO REDUCE HEAT LOSS. 2017 FBC-
 ENERGY- SEC. R 403.10.3.
  
 6. SEPARATE PERMIT REQUIRED FOR GAS PER WPB AMENDMENTS
 TO THE FBC SEC. 105.1
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-09-18 Cont ID  
Sent By rfalcone Date 2019-09-18 Time 15:50 Rev Time 0.00
Received By rfalcone Date 2019-09-18 Time 15:50 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-08-29 Cont ID  
Sent By rfalcone Date 2019-08-29 Time 10:34 Rev Time 0.00
Received By rfalcone Date 2019-08-29 Time 10:34 Sent To B
Notes
***NONE***