| Plan Review Stops For Permit 19081209 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-11-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-11-01 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-01 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-20 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-19 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2019-09-20 15:47:22 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE HAS BEEN ADJUSTED FROM $390,000 TO $412,750 | | | PER THE ICC BUILDING VALUATION DATA PUBLISHED AUGUST | | | 2019. | | | | | | 2. PROVIDE SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | | | | 3. SEVERAL PRODUCT APPROVALS ARE MISSING FROM THE | | | WINDOW SCHEDULE ON PLAN PAGE A-1. | | | | | | 4. PALM BEACH COUNTY IMPACT FEES MAY APPLY. | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-10-23 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-10-23 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-10-23 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-09-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-18 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-18 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2019-09-18 10:47:30 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RISER DIAGRAM SHOWS 250 KCMIL WIRE FEEDING A 320 AMP | | | SERVICE. THIS WIRE SPECIFIED HAS THE CAPACITY FOR A 300 | | | AMP SERVICE AND IS THEREFORE UNDERSIZED. BE ADVISED, | | | THAT 320 AMPS IS NOT A STANDARD FUSE SIZE. PROVIDE | | | CORRECTIONS. NEC 310.15(B)(7) AND (B)(16); FBC RE | | | E3603.1, E3705.1 | | | 2. ALL RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS | | | SHALL HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8(A)(9); FBC RE E3902.9 | | | 3. THE DISHWASHER AND DISPOSAL ARE SHOWN ON A 25 AMP | | | BREAKER FED WITH #12 WIRE. PROVIDE CORRECTION. NEC | | | 240.4(D); FBC RE E3705.5.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-11-15 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-13 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2019-11-14 13:28:40 | IMPACT FEES ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-11-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-11-01 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-10 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-20 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-23 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-11-15 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-15 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2019-11-15 09:33:39 | MU-2019-034845-0000. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-20 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-19 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2019-09-20 15:48:06 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-11-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-11-01 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-01 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-19 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-09-19 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-09-19 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2019-09-19 14:28:47 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED 2 COPYS OF ENERGY CALCULATIONS PER WEST PALM | | | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, 6TH | | | EDITION (2017), CHAPTER 1, ADMINISTRATION SEC 107.1 | | | GENERAL. | | | | | | 2 - NEED EQUIPMENT SIZING. PER 2017 FLORIDA BUILDING | | | CODE - RESIDENTIAL, SIXTH EDITION SEC M1401.3 EQUIPMENT | | | AND APPLIANCE SIZING. | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-10-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-23 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-23 |
Time |
12:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-08-30 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-08-30 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-08-30 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2019-08-30 17:01:36 | 08/30/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-20 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-19 |
Time |
16:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-10-17 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-10-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-10-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-17 15:17:55 | ZONING APPROVED WITH THE FOLLOWING PROVISOS: | | | | | | 1.) PRIOR TO THE ISSUANCE OF A CERTIFICATE OF | | | OCCUPANCY, A LANDSCAPE PERMIT, WHICH INCLUDES A | | | LANDSCAPE PLAN IN COMPLIANCE WITH THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, ARTICLE XIV, SHALL BE | | | SUBMITTED TO THE BUILDING DIVISION FOR REVIEW. | | | | | | 2.) AN IRRIGATION PERMIT ALL BE SUBMITTED TO THE | | | BUILDING DIVISION FOR REVIEW. | | | | | | 3.) THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED | | | LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL | | | LANDSCAPE INSPECTION. | | | | | | 4.) THE IRRIGATION SHALL BE INSTALLED IN ACCORDANCE | | | WITH THE APPROVED IRRIGATION PERMIT AND PASS A FINAL | | | PLUMBING INSPECTION. | | | | | | | | | NOTE(S): | | | | | | * SEPARATE PERMITS REQUIRED FOR: LANDSCAPING, | | | IRRIGATION, DRIVEWAY/WALKWAYS, SWIMMING POOL, WALL. | | | | | | * SEE ATTACHED CONDITIONAL APPROVAL DOCUMENT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-08-30 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-08-30 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2019-08-30 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-30 14:52:13 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) SHOW 5 FT. WIDE UTILITY EASEMENT AT THE REAR OF THE | | | PROPERTY PER THE SURVEY OF THE PROPERTY. | | | | | | 2.) PROPOSED DRIVEWAY SHALL NOT EXCEED 20 FT. IN WIDTH | | | AT THE PROPERTY LINE. [ZLDR S.94-312] | | | | | | 3.) PROVIDE THE REQUIRED FRONT YARD LANDSCAPE | | | CALCULATIONS. PLEASE NOTE THAT THE REQUIRED FRONT YARD | | | (AREA WITHIN THE FIRST 25 FT. OF SUMMA ST.) SHALL BE | | | LANDSCAPED WITH VEGETATIVE MATERIAL. [ZLDR S.94-482] | | | | | | 4.) SHOW SETBACK DISTANCE FROM ALL MECHANICAL EQUIPMENT | | | TO THE PROPERTY LINE(S). PLEASE NOTE THAT ANY | | | MECHANICAL EQUIPMENT SHALL NOT PROJECT MORE THAN 4 FT. | | | INTO A REQUIRED SETBACK. [ZLDR S.94-305] | | | | | | 5.) HOW TALL ARE THE PROPOSED SIDE GATES? PLEASE NOTATE | | | DIMENSION IN THE SITE PLAN. | | | | | | 6.) SITE PLAN SHOWS A DETAIL OF A 6 FT. HIGH SITE WALL; | | | HOWEVER, THE SITE WALL IS NOT ILLUSTRATED IN THE PLANS. | | | PLEASE ILLUSTRATE SO THAT STAFF CAN ASSESS IF THE WALL | | | IS IN COMPLIANCE WITH THE ZLDRS | | | | | | | | | | | | NOTES: | | | | | | * CONDITIONAL APPROVAL FOR LANDSCAPING PROVIDED ? NEEDS | | | P&Z ADMINISTRATOR AND BUILDING OFFICIAL SIGNATURES. | | | | | | * SEPARATE PERMITS AND REVIEWS REQUIRED FOR: | | | LANDSCAPING, DRIVEWAY AND HARDSCAPES, SWIMMING POOL | | | | | | * REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|