Plan Review Details - Permit 19081130
Plan Review Stops For Permit 19081130
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2019-10-01 Cont ID  
Sent By shill Date 2019-10-01 Time 16:25 Rev Time 0.00
Received By shill Date 2019-10-01 Time 16:25 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2019-09-30 Cont ID  
Sent By jwitmer Date 2019-09-30 Time 15:38 Rev Time 0.00
Received By jwitmer Date 2019-09-30 Time 15:20 Sent To  
Notes
2019-09-30 15:37:59ASBESTOS COMMERCIAL: PLEASE PROVIDE A SIGNED
 ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON LETTERHEAD,
 STATING THAT THE INSTRUCTIONS ON THE WEBSITE OF
 ASBESTOS PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF
 HEALTH PALM BEACH COUNTY WILL BE FOLLOWED AND THAT
 NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL
 INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE
 FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/_DOCUMENTS/ASBESTOS-
 NOTIFICATION-FORM-PBC-FILLABLE-UPDATE-07-30-2015.PDF
  
 901 EVERNIA STREET
 WEST PALM BEACH, FL 33401
 (561) 837-5900 ASBESTOS PROGRAM COORDINATOR
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
  
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2019-09-17 Cont ID  
Sent By jwitmer Date 2019-09-17 Time 06:12 Rev Time  
Received By jwitmer Date 2019-09-17 Time   Sent To  
Notes
2019-09-17 06:12:32PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-30 Cont ID  
Sent By jwitmer Date 2019-09-30 Time 15:36 Rev Time 0.00
Received By jwitmer Date 2019-09-30 Time 15:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-09-17 Cont ID  
Sent By jwitmer Date 2019-09-17 Time 06:09 Rev Time  
Received By jwitmer Date 2019-09-17 Time   Sent To  
Notes
2019-09-17 06:10:242017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19081130
 ADD: 120 S OLIVE AVE. SUITE- 210
 CONT: PATTERSON CONSTRUCTION GROUP
 TEL: 954-649-5986
 E-MAIL: INFO@PATTERSON CONSTRUCTIONGROUP.COM
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. SEPT. 17/2019
 ACTION: DENIED
  
 1) THE SUBMITTED FLOOR PLAN A1.20 DOES NOT INDICATE
 WITHIN THE TENANT SPACE WHERE THE RESTROOMS ARE
 LOCATED. PLEASE REVIEW THE 2017 FBC-B SECTION 2902.3.
  
 2) THE SUBMITTED FLOOR PLAN A-1.20 SHOWS A KITCHENETTE,
 ROOM 108 AND A KITCHEN SINK. SHEET A-4.00 DETAIL 2
 SHOWS AN ELEVATION VIEW OF THE SAME KITCHENETTE AND
 KITCHEN SINK. IN THIS SAME DETAIL THE DESIGNER OF
 RECORD INDICATES THE USE OF AN INTEGRAL TOE KICK. WHAT
 IS MISSING IN THE FLOOR PLAN VIEW IS THE REQUIRED CLEAR
 FLOOR SPACE AS IN THE 2017 FBC-ACCESSIBILITY CODE
 SECTION 606.2, ALSO REVIEW THE EXCEPTION 1A.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-09-16 Cont ID  
Sent By fgiaquin Date 2019-09-16 Time 07:39 Rev Time 0.00
Received By fgiaquin Date 2019-09-16 Time 06:15 Sent To  
Notes
2019-09-16 07:39:06APPROVED WITH PROVISIONS:
  
 PROVIDE LOAD CALCULATION FOR PANEL FEEDING NEW PANEL.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-09-26 Cont ID  
Sent By J.Walker Date 2019-09-26 Time   Rev Time 0.00
Received By jwalker Date 2019-09-26 Time   Sent To  
Notes
2019-09-26 07:36:08PERMITS AND SHOP DRAWINGD WILL BE REQUIRED FOR
 1 ) FIRE SPRINKLER SYSTEM MODIFICATIONS PER NFPA 13
 2 ) FIRE ALARM MODIFICATIONS PER NFPA 72

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-08-30 Cont ID  
Sent By J.Walker Date 2019-08-30 Time   Rev Time 0.00
Received By jwalker Date 2019-08-29 Time 14:52 Sent To B
Notes
2019-08-29 14:57:49WILL REQUIRE SHOP DRAWINGS AND PERMITS FOR
 1) FIRE SPRINKLER WORK PER (NFPA 13)
 2) FIRE ALARM WORK PER (NFPA 72)

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-10-02 Cont ID  
Sent By lmarchan Date 2019-10-02 Time 15:21 Rev Time 0.00
Received By lmarchan Date 2019-09-24 Time 08:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-09-17 Time   Rev Time 0.00
Received By lmarchan Date 2019-08-26 Time 07:45 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-09-17 Cont ID  
Sent By jwitmer Date 2019-09-17 Time 06:10 Rev Time  
Received By jwitmer Date 2019-09-17 Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-10-01 Cont ID  
Sent By ccole Date 2019-10-01 Time 15:07 Rev Time 0.00
Received By ccole Date 2019-10-01 Time 12:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-09-16 Cont ID  
Sent By ccole Date 2019-09-16 Time 09:12 Rev Time 0.00
Received By ccole Date 2019-09-16 Time 09:12 Sent To  
Notes
2019-09-16 09:18:331ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19081130
 9/16/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) 1) SHEET M102: THE LOUVERED AC DOORS SHALL BE NON
 COMBUSTIBLE PER SECTION C403.2.9.2 FBC EC. WOOD DOORS
 ARE SPECIFIED IN THE SCHEDULE ON SHEET A6.00.
  
 2) M102: REVISE NOTES #6, 7, 8 TO REMOVE MANUAL
 DAMPERS- C403.2.4.3 FBC EC.
  
 3) M102: PROVIDE A NOTE INDICATING A TEST AND BALANCE
 REPORT FOR THE NEW AC SYSTEMS WILL BE PROVIDED FOR
 FINAL APPROVAL- SECTION C408.2.2 FBC EC.
  
 4) PROVIDE AC LOAD CALCULATIONS FOR THE PROPOSED NEW
 SYSTEMS- SECTION C403.2.1 FBC EC, SECTION 312.1 FBC M.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-10-01 Cont ID  
Sent By shill Date 2019-10-01 Time 11:46 Rev Time 0.00
Received By shill Date 2019-09-28 Time 17:10 Sent To  
Notes
2019-10-01 11:46:52PROVISO APPROVAL, REVIEWED BY TIM HUNT
  
 1) WATER HEATER RELIEF SHALL DISCHARGE THOUGH AN AIR
 CAP IN THE SAME ROOM AS THE HEATER AND NOT CONNECT INTO
 THE DRAINAGE SYSTEM FBC-PLB 504.6
  
  
 2) A WATER HEATER PAN AND PAN DRAIN IS REQUIRED. PAN
 DRAIN SHALL BE DRAINED BY AN INDIRECT WASTE PIPE TO AN
 APPROVED WASTE RECEPTOR, FLOOR DRAIN, OR DISCHARGE TO
 THE OUTSIDE. FBC-PLB 504.7, 504.7.1, 504.7.2
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-09-09 Cont ID  
Sent By thunt Date 2019-09-09 Time 07:50 Rev Time 0.00
Received By rmcdouga Date 2019-09-09 Time 07:50 Sent To  
Notes
2019-09-09 07:50:59PLUMBING 1ST REVIEW**DENIED**
  
 1) SHOW KITCHENETTE CLEAR FLOOR SPACE ON PLAN 30? X
 48?. A FORWARD APPROACH IS REQUIRED. FBC-ACC 804.3.1
 2) PROVIDE CLEAR FLOOR SPACE ON PLAN FOR ALL KITCHEN
 APPLIANCES. FBC-ACC 804.6.1, 804.6.4
 3) PASS THROUGH KITCHENETTES REQUIRE 40? MIN BETWEEN
 ALL WALLS, CABINETS AND FIXTURES. YOUR PLAN SHOWS ONLY
 36?. FBC-ACC 804.2.1
 4) THE TANKLESS WATER HEATER SPEC PROVIDE IS NOT ABLE
 TO PRODUCE HOT WATER TO THIS FIXTURE AS REQUIRED.
 FBC-PLB 607.1. HEAT RISE MUST BE MIN 40F @ 2.2 GPM.
 FBC-PLB 604.3
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH (CGA SOLUTIONS)
 [email protected]
 561-248-2703
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-10-02 Cont ID  
Sent By lmarchan Date 2019-10-02 Time 15:21 Rev Time 0.00
Received By lmarchan Date 2019-10-02 Time 15:21 Sent To  
Notes
2019-10-01 15:08:48MECH SHEETS OK.
 CCOLE- 10/1/19

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-09-17 Time   Rev Time 0.00
Received By   Date 2019-09-17 Time   Sent To  
Notes
2019-09-17 06:22:5609/17/19 ARCHITECTURAL SHEETS ELECTRONIC SIGNATURE. OK.
 JW
2019-08-27 07:50:348/27/19 DIGITALLY SIGNED VERSION OF 004 A-1.10
 DEMOLITION FLOOR PLAN IS UNDER "SIGNATURES" FOLDER. LEM

Review Stop Z ZONING
Rev No 2 Status P Date 2019-10-02 Cont ID  
Sent By aaponte Date 2019-10-02 Time 15:04 Rev Time 0.00
Received By aaponte Date 2019-10-02 Time 15:04 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-09-12 Cont ID  
Sent By aaponte Date 2019-09-12 Time 15:56 Rev Time 0.00
Received By aaponte Date 2019-09-12 Time 15:56 Sent To  
Notes
***NONE***