| Plan Review Stops For Permit 19081109 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2019-08-23 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2019-08-23 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2019-08-23 11:32:04 | NO DEMOLITION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-27 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-27 |
Time |
13:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-08-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-08-22 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-08-22 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2019-08-22 13:21:13 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | PROVISIO | | | | | | 1) PANEL NEEDS MAIN | | | 2) NEED SIZE OF WATER HEATER | | | 3) SEE APNEL SCHEDULE FOR PROBLEMS | | | 4) NEED BRANCH CKT #S ON PLAN | | | 5) NEED LOAD CALC FOR SERVICE | | | 6) NEED FAULT CURRENT CALC FOR SERVICE | | | 7) PLAN SHOWS 4 SWITCHES IN DOORWAY | | | 8) E5 NOT SHOWN ON PANEL SCHEDULE | | | | | | SUBMIT BEFORE FINAL ELECTRICAL INSPECTION. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-08-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-08-23 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2019-08-23 14:44:03 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) THERE IS AN INDICATION OF A TWO BURNER HOTPLATE. | | | HOTPLATE COOKING SHALL NOT PRODICE GREASE LADIN VAPORS | | | UNLESS PROTECT BY A HOOD AND SUPPRESSION SYSTEM. | | | | | | PLEASE ENSURE COMPLIANCE. | | | | | | | | | 2) THERE IS AN INDICATION OF A WOOD BURNING PIZZA OVEN | | | UNDER SEPARATE PERMIT. | | | | | | PLEASE ENSURE THAT THE PROPOSED OVEN IS LISTED AND THAT | | | THE MANUFACTURES SPECIFICATION SHEET(S) IS SUBMITTED. | | | | | | | | | | | | 3) THERE IS AN INDICATION OF A WOOD BURNING PIZZA OVEN | | | UNDER SEPARATE PERMIT. | | | | | | ON SUBMITTAL OF THE OVEN PERMIT, PLEASE PROVIDE DETAILS | | | OF WHERE THE WOOD WILL BE STORED AND HOW MUCH. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-27 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-22 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-10 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-10 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2019-09-10 16:14:19 | OK-PLANS STAMPED | | | MU-2019-27837-0000 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-27 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-27 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2019-08-27 16:41:12 | 109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU | | | MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-08-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-08-22 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-08-22 |
Time |
11:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-08-23 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-08-23 |
Time |
12:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-08-23 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-08-23 |
Time |
12:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-08-23 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-08-23 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2019-08-23 15:48:37 | PERMIT APPROVED PER PLANS AND FOR INTERNAL WORK ONLY. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | |
|
|