| Plan Review Stops For Permit 19081001 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-09-13 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-09-13 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2019-09-13 15:13:53 | NO LOAD BEARING MEMBERS ARE BEING REMOVED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-10-07 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-10-07 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2019-10-07 09:45:09 | BUILDING PROVISO | | | REVISED PLANS ADDRESSING THIS ISSUE SHALL BE SUBMITTED | | | AND APPROVED BEFORE FINAL BUILDING INSPECTION PER PHONE | | | CONVERSATION WITH ALAN BIRSE, ARCHITECT. FBC | | | ACCESSIBILITY SECTION 202.4 ALTERATIONS AFFECTING | | | PRIMARY FUNCTION AREAS. DOOR #10 BETWEEN CORRIDOR 811 | | | AND 810 IS REQUIRED TO HAVE 18 INCHES AT THE LATCH ON | | | THE PULL SIDE OF THE DOOR. SEE SECTION 404.2.4.1 FOR A | | | FRONT APPROACH TO THE PULL SIDE OF A SWING DOOR. | | | ANOTHER OPTION WOULD BE TO REMOVE THIS DOOR AND CREATE | | | A CASED OPENING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-10-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-10-03 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-10-01 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2019-10-03 09:33:34 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC ACCESSIBILITY SECTION 202.4 ALTERATIONS | | | AFFECTING PRIMARY FUNCTION AREAS. DOOR #10 BETWEEN | | | CORRIDOR 811 AND 810 IS REQUIRED TO HAVE 18 INCHES AT | | | THE LATCH ON THE PULL SIDE OF THE DOOR. SEE SECTION | | | 404.2.4.1 FOR A FRONT APPROACH TO THE PULL SIDE OF A | | | SWING DOOR. ANOTHER OPTION WOULD BE TO REMOVE THIS DOOR | | | AND CREATE A CASED OPENING. | | | | | | 2) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-09-13 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-09-13 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-09-12 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-09-12 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-09-12 |
Time |
07:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-08-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-08-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-08-22 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-10-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-10-03 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-09-24 |
Time |
09:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-09-13 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-08-20 |
Time |
15:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-09-13 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-09-13 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-09-13 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-09-13 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2019-09-13 15:38:59 | NO MECHANICAL PLANS WERE SUBMITTED. A SEPERATE | | | APPLICATION, PLAN REVIEW AND PERMIT IS REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-10-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-01 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-09-28 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2019-10-01 11:49:20 | 1 OF THE NEW EXAM ROOM SINKS SHALL MEET FLORIDA | | | ACCESSIBILITY SECTIONS 212.3 AND 606 | | | REVIEWED BY TIM HUNT | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-09-06 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-09-06 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-09-06 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2019-09-06 07:45:42 | PLUMBING 1ST REVIEW**DENIED**19081001 | | | | | | 1-SUB PLUMBING PERMIT/ APPLICATION REQUIRED. FBC 105.1 | | | 2-SHT. A0.01 UNDER APPLICABLE CODE LIST THE 2014 5TH | | | EDITION. PLEASE CORRECT LISTING THE CORRECT 2017 6TH | | | EDITION TO MATCH THE OTHER CODE IN EFFECT. FBC 107.1 | | | 3-PROVIDE DIMENSIONS FOR ALL ROOMS. FBC 107.3.5 | | | 4-SHT. A0.11 UNDER ACCESSIBILITY NOTE #17 IT LEADS ME | | | TO BELIEVE THE EXISTING UNISEX TOILET ROOM WILL FULLY | | | COMPLY WITH CURRENT ADA. PLEASE CLARIFY AND IF SO THE | | | FOLLOWING COMMENTS APPLY. | | | 4A-UNDER ACCESSIBILITY NOTE #18 IT LIST THE MOUNTING OF | | | THE MIRROR TO BE 40? FROM THE BOTTOM EDGE. THE | | | MEASUREMENT FOR MIRRORS IS TO THE REFLECTIVE SURFACE. | | | FBC-ACC 603.3 | | | 4B-UNDER ACCESSIBILITY NOTE #18 IT CALLS FOR THE TOILET | | | PAPER DISPENSER MOUNTING 12? FROM THE LIP OG THE | | | TOILET. FLORIDA ACCESSIBILITY REQUIRES 7? TO 9? TO THE | | | CENTER OF THE ROLL. FBC-ACC 604.7 | | | 4C-UNDER ACCESSIBILITY DETAIL #20 GRAB BAR DETAIL IS | | | CONFUSING AND DOES NOT MEET THE INSTALLATION PER | | | FBC-ACC 604.5, 604.5.1, 604.5.2, 609.4. PLEASE PROVIDE | | | A GRAB BAR DETAIL. FBC 107.3.5 | | | 4D-UNDER ACCESSIBILITY NOT #26 PLEASE INCLUDE THE COLD | | | WATER AS BEING INSULATED FOR PROTECTION AND NOT JUST | | | THE HOT AND DRAIN LINE. FBC-ACC 606.5 | | | 5-SHT. PO.1 ONLY SHOW 1 NEW SINK AND 1 POINT OF USE | | | WATER HEATER BUT THE DEMO SHOW ONLY 1 EXISTING BUT NEW | | | LAY OUT SHOWS 4 TOTAL.PLEASE CORRECT THE PLUMBING | | | FIXTURE SCHEDULE. | | | 6- PROVIDE A COMPLETE SANITARY AND DOM WATER ISOMETRIC | | | TO INCLUDE ALL NEW SINKS. FBC 107.3.5 | | | 7-PROVIDE NOTE ON PLAN THAT EACH SINK SHALL BE TEMPERED | | | TO MAX 110F BY A ASSE 1070 DEVICE. TEMPERING BY MEANS | | | OF THE WATER HEATERS TEMP CONTROL IS NOT PERMITTED. | | | FBC-ACC 607.1.1, 607.1.2 | | | 8- PROVIDE THE CLEAR FLOOR SPACE ON ALL REQUIRED | | | FIXTURES THAT WILL MEET FLORIDA ACCESSIBILITY. FBC | | | 107.3.5 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH (CGA SOLUTIONS) | | | [email protected] | | | 561-248-2703 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-10-01 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-10-01 |
Time |
16:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-09-13 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-09-13 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2019-09-13 15:40:05 | CURRENT PLANS SIGNATURES ARE APPROVED. ANY NEW PLAN | | | SHEETS WILL HAVE TO BE CHECKED FOR VALID SIGNATURES. |
|
|