Plan Review Details - Permit 19080990
Plan Review Stops For Permit 19080990
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-10-07 Cont ID  
Sent By rmcdouga Date 2019-10-07 Time 11:10 Rev Time 0.00
Received By rmcdouga Date 2019-10-07 Time 10:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-10-03 Cont ID  
Sent By rmcdouga Date 2019-10-03 Time 08:48 Rev Time 0.00
Received By rmcdouga Date 2019-10-02 Time 18:58 Sent To I
Notes
2019-10-03 08:48:13PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE VALUE FOR THIS WORK HAS BEEN ADJUSTED TO
 $7309.00 FROM $5000.00 BASED ON MARSHALL-SWIFT
 VALUATION. FBC 109.3 BUILDING PERMIT VALUATION. FOR
 PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS
 SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 2) THE MAXIMUM DESIGN PRESSURE FOR THE FASTENING OPTION
 #1 THAT YOU SELECTED ON PAGE 21 OF NOA NO.18-0919.07 IS
 -52.5 PSF. THIS IS NOT ADEQUATE FOR THE HIGHER
 PRESSURES REQUIRED AT THE PERIMETER AND CORNER ROOF
 AREAS. THIS PROJECT IS LOCATED IN A 170 MPH VULT
 WINDSPEED, EXPOSURE C. SUBMIT TWO SETS OF RAS 117
 ENHANCED FASTENING CALCULATIONS AS REQUIRED BY
 LIMITATION #7 ON PAGE 27 OF THE NOA. NOTE: THE CITY OF
 WEST PALM BEACH DOES NOT ACCEPT THE PALM BEACH COUNTY
 ROOFING FORMS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-08-21 Cont ID  
Sent By rmcdouga Date 2019-08-21 Time 15:29 Rev Time 0.00
Received By rmcdouga Date 2019-08-21 Time 14:35 Sent To  
Notes
2019-08-21 15:29:55PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE DESCRIPTION OF WORK ON THE PERMIT APPLICATION
 SPECIFIES ROOF REPAIR. PROVIDE A COMPLETE DESCRIPTION
 OF THE REPAIRS THAT ARE TO BE DONE. MARK THE AREAS THAT
 WILL BE REPAIRED ON A ROOF DIAGRAM AND SPECIFY THE
 APPROXIMATE SQUARE FEET OF EACH OF THE AREAS. FBC
 107.2.1 FBC EXISTING BUILDING 706.1.1 NOT MORE THAN 25
 PERCENT OF THE TOTAL ROOF AREA OR ROOF SECTION OF ANY
 EXISTING BUILDING SHALL BE REPAIRED OR REPLACED IN ANY
 12 MONTH PERIOD UNLESS THE ENTIRE EXISTING ROOFING
 SYSTEM OR SECTION IS REPLACED.
  
 2) ON THE PRODUCT APPROVAL FOR THE MODIFIED BITUMEN
 ROOFING MARK THE SYSTEM TYPE AND DESIGN PRESSURE FOR
 THE SYSTEM THAT YOU WISH TO INSTALL. FBC 107.2.1

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-10-07 Cont ID  
Sent By rmcdouga Date 2019-10-07 Time 11:10 Rev Time 0.00
Received By rmcdouga Date 2019-10-07 Time 11:10 Sent To  
Notes
2019-10-07 11:11:42ROOFING RESUBMITTAL TURNED AROUND.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-10-03 Cont ID  
Sent By rmcdouga Date 2019-10-03 Time 08:48 Rev Time 0.00
Received By rmcdouga Date 2019-10-01 Time 13:45 Sent To  
Notes
2019-10-02 13:45:55RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-08-21 Cont ID  
Sent By rmcdouga Date 2019-08-21 Time 15:30 Rev Time 0.00
Received By rmcdouga Date 2019-08-20 Time 13:37 Sent To I
Notes
***NONE***