| Plan Review Stops For Permit 19080920 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-15 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-10-15 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-09-24 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-09-24 |
Time |
06:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-21 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-10-21 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2019-10-21 07:58:33 | ELECTRICAL REVISION TO BE SUBMITTED UNDER A NEW | | | REVISION | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-10-21 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-10-21 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2019-10-21 07:44:33 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE NEW COMMENT | | | BELOW. | | | | | | 1. CORRECTIONS TO PREVIOUS COMMENTS NOW SHOW THAT THERE | | | ARE 2 FEEDS FROM THE SAME PANEL TO THIS STRUCTURE. A | | | BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A BRANCH | | | CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC | | | 225.30 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-13 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-13 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2019-09-13 10:56:10 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. REVISION SHOWS TWO 150 AMP FEEDS FROM A PANEL THAT | | | IS NOT IDENTIFIED. WHERE IS THIS PANEL LOCATED, WHAT IS | | | THE DISTANCE OF THE FEEDERS? PROVIDE VOLTAGE DROP | | | CALCULATIONS TO COMPLY WITH CODE. FBC EC C405.6.3; WPB | | | FBC 107.2.1 | | | 2. PROVIDE ACCURATE LOAD CALCULATION FOR EXISTING | | | PANEL, INCLUDE EXISTING AND NEW LOADS TO CONFIRM | | | CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30 | | | 3. FEED FROM EXISTING PANEL TO PANELS SHOULD INCLUDE AN | | | EQUIPMENT GROUNDING CONDUCTOR. PROVIDE CORRECTION. NEC | | | 250.32(B), 250.118 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-08-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-08-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-08-22 |
Time |
13:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-10-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-09-27 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2019-10-21 06:23:17 | 10/21 TO JP DESK | | | | | 2019-10-15 14:06:47 | C12 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-09-24 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-08-19 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-10-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-10-15 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-10-15 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-09-16 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-09-13 |
Time |
17:01 |
Sent To |
|
|
| Notes |
| 2019-09-16 11:45:59 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M2.1: PROVIDE MAKEUP AIR FOR THE TOILET | | | EXHAUST FANS 3-6- SECTION 501.4 FBC M. | | | | | | 2) M2.1 & M2.2: A GRAVITY VENTILATOR (GH-1) FOR THE | | | KITCHEN IS SHOWN IN THE SCHEDULE BUT THE LOCATION IS | | | NOT SHOWN ON THE PLANS- SECTION 107.2.1 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-18 |
Time |
06:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-10-18 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2019-10-21 09:19:58 | REVIEWED BY GEORGE JOHNSON | | | SIGNED OFF ON REVISION FORM | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-09-12 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-09-10 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2019-09-12 11:26:11 | 1ST REVIEW: 19080920 | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. IT IS UNCLEAR WHAT PLUMBING HAS BEEN CHANGED PLEASE | | | PROVIDE A NARRATIVE. WPB AMEND TO FBC 107.2.1 | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 2. THE SANITARY AND STORM ISOMETRICS ARE MISSING. WPB | | | AMEND TO FBC 107.2.1 ADDITIONAL INFORMATION REQUIRED. | | | | | | 3. PLEASE ADD NOTES TO PLAN SEPARATE PERMITS REQUIRED | | | FOR GAS CONNECTIONS, GREASE INTERCEPTOR,BACK FLOW | | | PREVENTER'S. WPB AMEND TO FBC 107.2.1 ADDITIONAL | | | INFORMATION REQUIRED. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
ahansen |
Date |
2019-09-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
ahansen |
Date |
2019-09-24 |
Time |
11:16 |
Sent To |
I |
|
| Notes |
|
|