| Plan Review Stops For Permit 19080812 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-11-27 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-27 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-13 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-13 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2019-09-13 14:27:02 | ADDRESSING | | | | | | FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL): | | | | | | MICHAEL ORIO | | | GIS SUPPORT SPECIALIST | | | [email protected] | | | CITY OF WEST PALM BEACH | | | INFORMATION TECHNOLOGY DEPARTMENT | | | 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401 | | | P: 561.494.1080 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-02 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-27 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-13 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-13 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2019-09-13 14:53:26 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SITE DRAINAGE PLAN. - OK CT | | | | | | 2. PROVIDE WINDOW AND DOOR SCHEDULE. INCLUDE ROUGH | | | OPENINGS AND DESIGN PRESSURES. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR WINDOWS, DOORS AND | | | ROOFING. | | | DESIGNER SHALL REVIEW AND APPROVE IN WRITING. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-12-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-13 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-13 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-11-21 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-11-21 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-11-21 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2019-11-21 13:33:49 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. | | | 2. | | | 3. | | | 4. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-09-11 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-11 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-11 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2019-09-11 14:24:41 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR EXISTING MAIN | | | SERVICE, INCLUDE EXISTING AND NEW LOADS TO CONFIRM | | | CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, 220, | | | 408.30; FBC RE E3602.2 | | | 2. PROVIDE ACCURATE LOAD CALCULATION FOR SUB-PANEL. | | | DEMAND FACTORS ARE NOT PERMITTED TO BE USED WHEN THE | | | FEEDER IS LESS THAN 100 AMPS. NEC 220.82, 408.30; FBC | | | RE E3602.2.1 | | | 3. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR SUB-PANEL. NEC 225.31, | | | 225.32 | | | 4. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-11-15 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-11-15 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-08-29 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-08-29 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-08-29 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-02 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-12 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-13 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-15 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-11-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-11-27 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-27 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2019-11-27 11:02:47 | MU-2019-033601-0000. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-13 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-13 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2019-09-13 14:56:55 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-02 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-27 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-13 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-13 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2019-09-13 14:43:11 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE MECHANICAL PLAN. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-12-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-13 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-13 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-02 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-27 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2019-12-02 15:36:10 | PLAN REVIEW - PLUMBING | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PLUMBING RISER DIAGRAM REQUIRED WPB AMENDMENTS TO | | | THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL PLUMBING. (NOT | | | ADDRESSED) | | | | | | 2. PLEASE PROVIDE SOURCE OF HOT WATER, IF A DEVICE IS | | | BEING USED PROVIDE MANUFACTURES SPECIFICATION, 2017 FBC | | | RES. SEC. 2722.2. (PLAN SHOWS 28 GAL. WH - EQUIPMENT | | | TECH DATA IS FOR A TANKLESS WH - PLEASE CLARIFY) | | | | | | 3. A BACKFLOW PREVENTER MAY BE REQUIRED SINCE THIS A | | | DUAL DWELLING PER THE CITY OF WEST PALM BEACH ORD | | | #2853-95. A PERMIT REQUIRED BY A LICENSED CONTRACTOR | | | AND MUST BE CERTIFIED BY UTILITIES PRIOR TO FINAL | | | INSPECTION. PLEASE CONTACT CITY OF WPB UTILITIES AT | | | 561-822-2240 FOR FURTHER DIRECTIONS. (NOT ADDRESSED) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-08-27 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-08-27 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2019-08-27 18:10:11 | 08/27/2019 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLUMBING RISER DIAGRAM REQUIRED WPB AMENDMENTS TO | | | THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL PLUMBING. | | | | | | 2. PLEASE PROVIDE SOURCE OF HOT WATER, IF A DEVICE IS | | | BEING USED PROVIDE MANUFACTURES SPECIFICATION, 2017 FBC | | | RES. SEC. 2722.2. | | | | | | 3. A BACKFLOW PREVENTER MAY BE REQUIRED SINCE THIS A | | | DUAL DWELLING PER THE CITY OF WEST PALM BEACH ORD | | | #2853-95. A PERMIT REQUIRED BY A LICENSED CONTRACTOR | | | AND MUST BE CERTIFIED BY UTILITIES PRIOR TO FINAL | | | INSPECTION. PLEASE CONTACT CITY OF WPB UTILITIES AT | | | 561-822-2240 FOR FURTHER DIRECTIONS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-12-02 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-27 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-13 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-13 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2019-09-13 14:55:41 | BUILDING PLAN REVIEW -ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | | COMPONENTS. | | | DESIGNER SHALL REVIEW AND APPROVE IN WRITING. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-11-15 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-11-15 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-08-29 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-08-29 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-08-29 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|