Plan Review Details - Permit 19080767
| Plan Review Stops For Permit 19080767 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-10 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-10 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-08-26 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-08-26 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2019-08-26 10:58:54 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. WPB | | | FBC 107.2.1, 107.3.5; FS 471, 481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-09-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-09-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-09-06 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-08-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-08-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-08-16 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2019-08-16 11:10:28 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE NO PLANS SHEETS SUBMITTED TO REVIEW AND/OR | | | CONFIRM LOCATIONS OF DEVICES, AFFECTED DOORS AND FIRE | | | ALARM INTERFACES. | | | | | | PER NFPA 1 | | | | | | 1.7.11 PLANS AND SPECIFICATIONS. | | | | | | 1.7.11.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE | | | PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH | | | APPLICABLE CODES AND STANDARDS. | | | | | | 1.14 PLAN REVIEW. | | | | | | 1.14.1 WHERE REQUIRED BY THE AHJ FOR NEW CONSTRUCTION, | | | MODIFICATION, OR REHABILITATION, CONSTRUCTION DOCUMENTS | | | AND SHOP DRAWINGS SHALL BE SUBMITTED, REVIEWED, AND | | | APPROVED PRIOR TO THE START OF SUCH WORK AS PROVIDED IN | | | SECTION 1.14. | | | | | | 1.14.2 THE APPLICANT SHALL BE RESPONSIBLE TO ENSURE | | | THAT THE FOLLOWING CONDITIONS ARE MET: | | | (1) THE CONSTRUCTION DOCUMENTS INCLUDE ALL OF THE FIRE | | | PROTECTION REQUIREMENTS. | | | (2) THE SHOP DRAWINGS ARE CORRECT AND IN COMPLIANCE | | | WITH THE APPLICABLE CODES AND STANDARDS. | | | (3) THE CONTRACTOR MAINTAINS AN APPROVED SET OF | | | CONSTRUCTION DOCUMENTS ON SITE. | | | | | | | | | PLEASE SUBMITTED PLAN SHEETS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-09-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-09-05 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-08-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-08-15 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-10 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-10 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-08-26 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-08-26 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2019-08-26 11:01:06 | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A | | | DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY | | | VERIFICATION. PROVIDE CORRECTION. WPB FBC 107.1; FS | | | 471/481 |
|
|
|