Plan Review Details - Permit 19080753
Plan Review Stops For Permit 19080753
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-08-20 Cont ID  
Sent By pvalenti Date 2019-08-20 Time 11:31 Rev Time 0.00
Received By pvalenti Date 2019-08-20 Time 11:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-08-19 Cont ID  
Sent By pvalenti Date 2019-08-19 Time 16:34 Rev Time 0.00
Received By pvalenti Date 2019-08-19 Time 16:34 Sent To  
Notes
2019-08-19 16:41:23***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1 THE FLAME SPREAD SPECIFICATIONS FOR THE
 WHISPER MAT WITH TILE ARE OK BUT WE STILL NEED THE
 FLAME SPREAD SPECIFICATIONS FOR WHISPER MAT WITH THE
 LVT/VINYL FLOORING AS PER:
  
 FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-20 Cont ID  
Sent By cpuell Date 2019-08-20 Time 12:42 Rev Time 0.00
Received By cpuell Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-08-19 Cont ID  
Sent By pvalenti Date 2019-08-19 Time 16:41 Rev Time 0.00
Received By pvalenti Date 2019-08-14 Time 13:00 Sent To  
Notes
2019-08-15 13:01:10BLDG <5K