Plan Review Details - Permit 19080730
| Plan Review Stops For Permit 19080730 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-09-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-09-11 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-09-11 |
Time |
10:19 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-10-04 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-10-04 |
Time |
07:19 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-09-09 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-09-09 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-09-09 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2019-09-09 06:45:52 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. 200AMP ATS IS BEING FED WITH #1'S FROM A 150AMP | | | SERVICE. NEC 110.3B 240.4B | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-08-21 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-08-21 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-08-21 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2019-08-21 15:23:54 | 08/21/19 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-09-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-09-11 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-08-14 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2019-08-15 12:50:48 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-08-20 |
|
|
Cont ID |
|
| Sent By |
rfalcone |
Date |
2019-08-20 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
rfalcone |
Date |
2019-08-20 |
Time |
11:46 |
Sent To |
B |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |