Plan Review Details - Permit 19080658
Plan Review Stops For Permit 19080658
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2019-09-18 Cont ID  
Sent By jgomez Date 2019-09-18 Time 08:34 Rev Time 0.00
Received By jgomez Date 2019-09-18 Time 08:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-09-19 Cont ID  
Sent By jgomez Date 2019-09-19 Time 17:02 Rev Time 0.00
Received By jgomez Date 2019-09-19 Time 14:20 Sent To  
Notes
2019-09-19 14:20:2009/19/19 WAITING FOR CHUCK'S RESPONSE TO FINISH
 PROCESSING THE PERMIT.
  
  
 YES
 THAT IS IT
 THANK YOU!
  
 CHARLES MATHEWS
 FRANCO CONSTRUCTION INC.
 1011 NE JENSEN BEACH BLVD.
 JENSEN BEACH, FL. 34957
 PHONE: 772-334-9118
 CELL: 954-444-3732
 FAX: 772-679-6222
 ESTIMATE EMAIL: [email protected]
 WEBSITE: WWW.FRANCOCONSTRUCTIONINC.COM
  
  
 FROM: JULIO GOMEZ
 SENT: THURSDAY, SEPTEMBER 19, 2019 2:20 PM
 TO: SERVICE
 SUBJECT: 1701 S FLAGLER DR 1206 RE: PERMIT19080658 CORK
 SPECS
  
 HELLO CHUCK,
  
 THIS IS THE INFORMATION WE HAVE FOR THE QEP CORK.
 PLEASE LET ME KNOW IF THIS IS THE CORK YOU WANT TO USE
 AND I WILL PRINT THE INFORMATION AND FINISH PROCESSING
 THIS PERMIT.
 THANK YOU
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-19 Cont ID  
Sent By jgomez Date 2019-09-18 Time 17:48 Rev Time 0.00
Received By jgomez Date 2019-09-18 Time 17:48 Sent To  
Notes
2019-09-18 17:48:38 
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-09-18 Cont ID  
Sent By jgomez Date 2019-09-18 Time 08:41 Rev Time 0.00
Received By jgomez Date 2019-09-18 Time 08:30 Sent To E
Notes
2019-09-18 08:44:05RESIDENTIAL (R2) BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE:
 SEC. 702.6 FBC-EXISTING BUILDING CODE: MATERIALS AND
 METHODS.
 ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND
 METHODS REQUIREMENTS IN THE FLORIDA BUILDING CODE,
 BUILDING; FLORIDA BUILDING CODE, ENERGY CONSERVATION;
 FLORIDA BUILDING CODE, MECHANICAL; AND FLORIDA BUILDING
 CODE, PLUMBING, AS APPLICABLE, THAT SPECIFY MATERIAL
 STANDARDS, DETAIL OF INSTALLATION AND CONNECTION,
 JOINTS, PENETRATIONS, AND CONTINUITY OF ANY ELEMENT,
 COMPONENT, OR SYSTEM IN THE BUILDING.
  
 1- FLOORING SOUND INSULATION MATERIAL:
 A) PROVIDE 2 COPIES OF THE FLAME SPREAD INDEX AND SMOKE
 DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84
 OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 6TH EDITION
 (2017).
  
 B) PROVIDE 2 COPIES OF THE SOUND TRANSMISSION CLASS
 (STC) TEST DONE IN ACCORDANCE WITH ASTM E 90 AS
 REQUIRED BY SEC. 1207.2 OF FBC 6TH EDITION (2017).
  
 C) PROVIDE 2 COPIES OF THE IMPACT INSULATION CLASS
 (IIC) TEST DONE IN ACCORDANCE WITH ASTM E 492 AS
 REQUIRED BY SEC. 1207.3 OF FBC 6TH EDITION (2017).
  
 NOTE: TEST SAMPLES TO MATCH BUILDING CONSTRUCTION AND
 PROPOSED FLOOR FINISH. ALSO, THERE ARE TESTS FOR 6" OR
 8" CONCRETE SLABS WITH OR WITHOUT ACOUSTICAL CEILING.
 TYPICALLY THERE ARE NOT SUSPENDED ACOUSTICAL CEILINGS
 IN THESE BUILDINGS
  
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-09-19 Cont ID  
Sent By jleahy Date 2019-09-18 Time 09:36 Rev Time 0.00
Received By jleahy Date 2019-09-18 Time 09:36 Sent To  
Notes
2019-09-18 09:36:39NO ELECTRIC SHOWN ON DRAWINGS JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-09-16 Cont ID  
Sent By pleduc Date 2019-09-16 Time   Rev Time 0.00
Received By pleduc Date 2019-09-16 Time 14:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-09-19 Cont ID  
Sent By jgomez Date 2019-09-19 Time 17:02 Rev Time 0.00
Received By jgomez Date 2019-09-19 Time 14:19 Sent To  
Notes
2019-09-19 14:20:0209/19/19 WAITING FOR CHUCK'S RESPONSE TO FINISH
 PROCESSING THE PERMIT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-09-18 Cont ID  
Sent By jgomez Date 2019-09-18 Time 17:48 Rev Time 0.00
Received By jgomez Date 2019-09-18 Time 17:44 Sent To  
Notes
2019-09-18 17:48:06E-MAIL FROM CONTRACTOR.
  
 HI VINCENT,
 I AM PRINTING THESE REPORTS AND PASSING MY BUILDING
 REVIEW STOP. PLEASE VERIFY WITH YOUR SUPPLIER THAT THE
 MATERIAL IS ACOUSTICORK RC1000-10MM.
 I AM DONE WITH MY REVIEW. PLEASE COORDINATE WITH JAKE
 LEAHY (561)805-6713 (ELECTRICAL PLAN REVIEWER) FOR
 ELECTRICAL COMMENTS.
 THANK YOU.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  
 FROM: SERVICE
 SENT: WEDNESDAY, SEPTEMBER 18, 2019 3:07 PM
 TO: JULIO GOMEZ
 SUBJECT: RE: 1701 S FLAGLER DR 1206 PERMIT #19080658
 CORK SPECS
  
 I BELIEVE THAT THE ACOUSTIC CORK IS THE SAME OR SIMILAR
 PRODUCT , SO IF THESE REPORTS WILL WORK FOR ME THAT
 WOULD BE GREAT
 THANK YOU
 VINNY
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-09-18 Cont ID  
Sent By jgomez Date 2019-09-18 Time 11:38 Rev Time 0.00
Received By jgomez Date 2019-09-10 Time 15:00 Sent To I
Notes
2019-09-11 15:00:17B02

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-09-18 Cont ID  
Sent By jgomez Date 2019-09-18 Time 08:40 Rev Time 0.00
Received By jgomez Date 2019-09-18 Time 08:40 Sent To  
Notes
***NONE***