| Plan Review Stops For Permit 19080511 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-12-03 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-03 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-03 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2019-12-03 12:46:45 | PROVISOS: | | | 1) ROOFING PRODUCT APPROVALS DUE WITH ROOFING SUB | | | PERMIT. | | | 2) ROOF TRUSS SHOP DRAWINGS TO BE PROVIDED TO BUILDING | | | INSPECTOR PRIOR TO INSTALLATION | | | 3) SUBMITTAL FOR STAIRS, HANDRAILS AND GUARDRAILS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-10-21 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-10-21 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2019-10-21 10:44:58 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19080511 | | | 1ST REVIEW: SEPTEMBER 17, 2019 | | | 2ND REVIEW: OCTOBER 21, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[E] = FBC ENERGY CONSERVATION | | | FBC[R] = FBC RESIDENTIAL | | | FEMA P-758 | | | | | | 1. 501.1.1 FBC[RE] ADDITIONS, ALTERATIONS, OR REPAIRS: | | | GENERAL. ADDITIONS, ALTERATIONS, OR REPAIRS TO AN | | | EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF | | | SHALL COMPLY WITH SECTION R502, R503 OR R504. UNALTERED | | | PORTIONS OF THE EXISTING BUILDING OR BUILDING SUPPLY | | | SYSTEM SHALL NOT BE REQUIRED TO COMPLY WITH THIS CODE. | | | - PROVIDE DOCUMENTATION OF ENERGY CODE COMPLIANCE FOR | | | THE METHOD CHOSEN. | | | 2 ND REVIEW ADDITIONAL COMMENT. | | | NO DOCUMENTATION PROVIDED TO SHOW COMPLIANCE WITH | | | ENERGY CODE. PLEASE REVIEW COMMENT 1 AND PROVIDE | | | DOCUMENTATION FOR THE COMPLIANCE METHOD CHOSEN. | | | | | | 2. OK. | | | | | | 3. OK. | | | | | | 4. OK. | | | | | | 5. OK. | | | | | | 6. 322.2.2 FBC[R] ENCLOSED AREAS BELOW DESIGN FLOOD | | | ELEVATION. | | | - AREAS THAT ARE BELOW B.F.E. ,AND MEET THE | | | REQUIREMENTS OF R322.2.2 (1), NEED TO BE DESIGNED WITH | | | FLOOD OPENINGS AS OUTLINED IN R322.2.2 (2). | | | | | | R322.2.2 ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION. | | | ENCLOSED AREAS, INCLUDING CRAWL SPACES, THAT ARE BELOW | | | THE DESIGN FLOOD ELEVATION SHALL: (SEE R322.2.2 FOR | | | REQUIREMENTS) | | | | | | R322.2.2.1 INSTALLATION OF OPENINGS. THE WALLS OF | | | ENCLOSED AREAS SHALL HAVE OPENINGS INSTALLED SUCH THAT: | | | (SEE R322.2.2 FOR REQUIREMENTS) | | | | | | | | | 7. OK. | | | | | | WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-17 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-16 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2019-09-17 10:39:53 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19080511 | | | REVIEWED: SEPTEMBER 17, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[E] = FBC ENERGY CONSERVATION | | | FBC[R] = FBC RESIDENTIAL | | | FEMA P-758 | | | | | | THIS PROJECT MEETS THRESHOLD FOR A SUBSTANTIAL | | | IMPROVEMENT IN FLOOD ZONE AE. | | | PLEASE PROVIDE ELEVATION CERTIFICATE SO WE CAN REVIEW | | | BASE FLOOD ELEVATIONS (B.F.E.) | | | IF THE LOWEST FLOOR ELEVATION IS AT LEAST 9 FEET NAVD | | | THEN THE PROPOSED ADDITIONS AND REVOVATIONS CAN MOVE | | | FORWARD AS SHOWN. | | | OTHERWISE, ALL PORTIONS OF EXISTING BUILDINGS NEED TO | | | COME INTO COMPLIANCE WITH FEMA FLOOD ZONE PROVISIONS | | | AND THE CITY OF WPB ORDINANCES. | | | | | | I DID A PRELIMINARY REVIEW OF THE PROPOSED WORK SO THAT | | | ADDITIONAL MATERIALS COULD BE PROVIDED WHILE THE | | | REQUIREMENTS NEEDED TO MEET SUBSTANTIAL IMPROVEMENT ARE | | | BEING REVIEWED. ADDITIONAL COMMENTS MAY BE FORTHCOMING | | | PENDING REVIEW OF MATERIALS REQUESTED. | | | | | | 1. 501.1.1 FBC[RE] ADDITIONS, ALTERATIONS, OR REPAIRS: | | | GENERAL. ADDITIONS, ALTERATIONS, OR REPAIRS TO AN | | | EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF | | | SHALL COMPLY WITH SECTION R502, R503 OR R504. UNALTERED | | | PORTIONS OF THE EXISTING BUILDING OR BUILDING SUPPLY | | | SYSTEM SHALL NOT BE REQUIRED TO COMPLY WITH THIS CODE. | | | - PROVIDE DOCUMENTATION OF ENERGY CODE COMPLIANCE FOR | | | THE METHOD CHOSEN. | | | | | | 2. IS THE BUILDING PRE-FIRE OR POST FIRM (ADOPTED | | | SEPTEMBER, 1978)? | | | | | | 3. 107.3.5.3.1 FBC [AMENDED ]PROVIDE BASE FLOOD | | | ELEVATION (B.F.E.)CERTIFICATE WITH DESIGN FLOOD | | | ELEVATIONS TO INCLUDE ANY MECHANICAL EQUIPMENT AS | | | APPLICABLE. ALL ELEVATION CERTIFICATES CERTIFIED | | | OCTOBER 5, 2017 AND LATER ARE TO UTILIZE NAVD88 AND | | | INCLUDE A CONVERSION TO NGVD29. | | | - THIS PROJECT IS A SUBSTANTIAL IMPROVEMENT AND THE IF | | | THE B.F.E. IS LESS THAN 9 FEET THAN THE STRUCTURES WILL | | | NEED TO BE BROUGHT INTO COMPLIANCE. | | | | | | 4. 322.2.1 FBC[R] THE CITY OF WPB HAS ADOPTED A TWO | | | FOOT FREEBOARD ABOVE B.F.E. SEE AMENDMENT TO FBC | | | R322.2.1 IN ORD. NO. 4765-18, ? 2, 3-12-2018(SEC 18-33) | | | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS | | | AE WITH A BASE FLOOD ELEVATION (BFE) OF 7FT. THE CITY | | | OF WEST PALM BEACH (THROUGH ORDINANCE) REQUIRES AN | | | ADDITIONAL 24 INCHES OF FREEBOARD REQUIRING THE DESIGN | | | FLOOD ELEVATION (DFE) TO BE 9.0 FEET. PLEASE NOTE THIS | | | INFORMATION ON YOUR PLANS. A CONSTRUCTION DRAWING | | | ELEVATION CERTIFICATE IS REQUIRED AT TIME OF PERMIT | | | APPLICATION. NOTE: ALL EQUIPMENT SERVICING THE | | | BUILDINGS ON THIS SITE ARE REQUIRED TO BE AT OR ABOVE | | | 9.0 FEET NGVD. AN UNDER CONSTRUCTION (FORMBOARD) SURVEY | | | WITH FINISHED FLOOR ELEVATION IS RECOMMENDED. A | | | FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED | | | AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL PRIOR TO | | | THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | - CURRENT FLOOD ZONE = AE = B.F.E. 7 FEET PLUS 2 FOOT | | | FREEBOARD = 9 FOOT DESIGN FLOOD ELEVATION(D.F.E.) | | | | | | 5. 110.3(A)1.1 FBC[AMENDED] A FOUNDATION/FORM BOARD | | | SURVEY PREPARED AND CERTIFIED BY A REGISTERED SURVEYOR | | | MAY BE REQUIRED, PRIOR TO APPROVAL OF THE SLAB | | | INSPECTION. THE SURVEY SHALL CERTIFY PLACEMENT OF THE | | | BUILDING ON THE SITE, ILLUSTRATE ALL SURROUNDING | | | SETBACK DIMENSIONS AND SHALL BE AVAILABLE AT THE JOB | | | SITE FOR REVIEW BY THE BUILDING INSPECTOR. | | | - PLEASE PROVIDE TO BUILDING INSPECTOR AT THE JOB SITE. | | | | | | 6. 322.2.2 FBC[R] ENCLOSED AREAS BELOW DESIGN FLOOD | | | ELEVATION. | | | - SHOW ELEVATION OF GARAGE ON ELEVATION CERTIFICATE. | | | | | | 7. 301.2(7) FIGURE FBC[R] PROVIDE WIND DIAGRAM THAT | | | MATCHES THE ROOF CONDITION OF THIS HOUSE. | | | - ALSO, ADJUST MEAN ROOF HEIGHT ON SHEET A-4.1 IN WIND | | | DESIGN CRITERIA TO ACCOUNT FOR 3RD FLOOR ROOF DECK | | | HEIGHT. | | | | | | NOTES: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-12-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-18 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-18 |
Time |
06:49 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-10-31 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-10-31 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-10-31 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2019-10-31 15:41:37 | APPROVED WITH PROVISO ON PLAN FOR FEEDER SIZES, WIRE TO | | | FPL MUST BE SIZED FOR 350 AMP SERVICE PER NEC | | | 310.15(B)(7) AND FBC RE E3603.1.1. WIRE FROM METER TO | | | PANELS MUST BE SIZED PER NEC 310.15(B)(16) AND FBC RE | | | E3704.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-09-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-05 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-08-30 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2019-09-05 14:53:34 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RISER DIAGRAM SHOWS THE ELECTRICAL PANELS IN THE | | | GARAGE BEHIND THE METER CAN AND NO MAIN DISCONNECT IS | | | SHOWN. THE GROUND FLOOR ELECTRICAL PLAN SHOWS THE | | | PANELS IN THE HALLWAY ACROSS FROM THE LAUNDRY. | | | CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR | | | DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE | | | IN THIS FASHION. PROVIDE EITHER A MAIN ON THE OUTSIDE | | | OF THE HOME, OR INSTALL THE CONDUCTORS UNDER THE SLAB. | | | IF CONDUCTORS ARE INSTALLED UNDER THE SLAB, THEN THERE | | | SHOULD NOT BE AN EQUIPMENT GROUNDING CONDUCTOR IN THIS | | | CONDUIT. PROVIDE CORRECTIONS. NEC 230.70, 250.6; FBC RE | | | E3601.6 | | | 2. AFCI PROTECTION SHOWN IN ELECTRICAL NOTE 8 IS NOT | | | CODE COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY | | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | | PROTECTED. THIS INCLUDES LIGHTING AND POWER OUTLETS AND | | | RECEPTACLES. SOME AREAS REQUIRE BOTH AFCI AND GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12; FBC | | | RE E3902; FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS | | | APPLICABLE. | | | 3. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM | | | BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET | | | FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE | | | R314.3(4), NFPA 72:29.8.3.4 | | | 4. ELECTRICAL NOTE 17 STATES THAT LIGHTING IN CLOTHES | | | CLOSETS SHALL COMPLY WITH NEC 410.8, WHICH DOESN?T | | | APPLY TO LIGHTING IN CLOSETS. PROVIDE CORRECTION. NEC | | | 410.16; FBC RE E4003.12 | | | 5. ELECTRICAL NOTE 22 STATES THAT RECEPTACLES SHALL BE | | | TAMPER RESISTANT PER NEC 406.11. THIS CODE SECTION DOES | | | NOT APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | | 6. RECEPTACLES INSTALLED TO SERVE THE COUNTER TOP IN | | | KITCHEN REQUIRE GFCI PROTECTION, INCLUDING THE ISLAND. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.6 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2019-12-17 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-12-17 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-12-17 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2019-12-17 14:19:08 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | NFPA 99 = HEALTH CARE FACILITIES CODE | | | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 2ND REVIEW | | | | | | GAS COMMENTS: DENIED | | | | | | REGARDING PAST REVIEW DATED 10/23/2019 | | | 1. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2017 FUEL GAS APPENDIX A; USE | | | OF CAPACITY SECTION A.3.1(4) & 2017 FUEL GAS CODE SEC. | | | 402.4.1. | | | REGARDING COMMENT #1; PER WPB FBC 107.2.1 AND | | | 107.3.5.3(13), OUTLET FOR FUTURE BBQ SHALL BE INCLUDED | | | IN CALCULATIONS. CALCULATIONS BASED ON FBC FG TABLE | | | 402.4(2) MAXIMUM 90? POINT OF DELIVERY TO FARTHEST | | | OUTLET. THEREFORE, THE BRANCH TO THE FUTURE BBQ OUTLET | | | AT 120CFH IS UNDERSIZED. | | | 2. COMPLIED | | | 3. SECOND REQUEST: SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, LENGTH, SIZE AND TERMINATION OF THE GAS VENTS | | | PER FBC-2017 FUEL GAS CODE SEC. 502 THRU 505. | | | ADDITIONAL COMMENT: THIS APPLIES TO THE LINEAR GAS | | | FIREPLACE AND IF LOCATED INDOORS, THE GAS TANKLESS | | | WATER HEATERS. | | | 4. SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT AND REGULATORS TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2017 FUEL GAS SEC. | | | 402.2 | | | REGARDING COMMENT #4 FROM LAST REVIEW; PER WPB FBC | | | 107.2.1 AND 107.3.5.3(13), THE MANUFACTURER?S | | | SPECIFICATION SHEETS PROVIDED AS REQUIRED BY WPB FBC | | | 107.2.1 AND 107.3.5.3(13) ARE INCOMPLETE. PER WPB FBC | | | 107.2.1 AND WPB FBC AND 107.3.5.3(13), PROVIDE THE | | | MANUFACTURER?S SPECIFICATION SHEETS FOR ALL GAS FIRED | | | EQUIPMENT AND APPLIANCES. INFORMATION PROVIDED SHALL | | | INCLUDE BUT NOT BE LIMITED TO MODEL NUMBER, BTU INPUT, | | | FUEL TYPE, VENTING REQUIREMENTS/CONNECTIONS WHERE | | | APPLICABLE, GAS CONNECTION LOCATION AND SIZE AND | | | MAXIMUM PRESSURE INLET REQUIREMENTS. INCLUDE | | | REGULATORS, DRYER, COOKTOP, LINEAR GAS FIREPLACE, | | | FUTURE BBQ AND TANKLESS WATER HEATERS. SHOW OUTDOOR | | | RATING IF APPLICABLE. BTU INPUT ON SUBMITTALS SHALL | | | MATCH INFORMATION NOTED ON THE PLAN. | | | 5. COMPLIED | | | 6. COMPLIED | | | | | | NEW COMMENTS: | | | 1. SHOW LOCATIONS OF TANKLESS WATER HEATERS ON THE | | | FLOOR PLAN. | | | 2. PROVIDE LOCATION OF FUTURE BBQ GRILL ON FLOOR PLAN | | | 3. REGARDING REGULATORS INSTALLED INDOORS, IF VENT | | | ELIMINATORS ARE TO BE USED IN LIEU OF VENT PIPING TO | | | EXTERIOR, PROVIDE A NOTE STATING SUCH AND PROVIDE A | | | MANUFACTURER?S SPECIFICATION SHEET FOR THE VENT | | | ELIMINATOR. CONFIRM THE SUBMITTED REGULATOR AND VENT | | | ELIMINATOR ARE COMPATIBLE. OTHERWISE, PROVIDE VENT PIPE | | | ROUTING, SIZE, TERMINATION AND MATERIAL FOR VENTS TO | | | THE OUTSIDE. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19080511 215 9TH ST | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-10-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-23 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-23 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2019-10-23 10:07:57 | 1ST REVIEW: 19080511 | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | GAS COMMENTS: | | | | | | 1. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2017 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2017 FUEL GAS CODE | | | SEC. 402.4.1. | | | | | | 2. PLEASE SHOW METER ON FLOOR PLAN. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 3. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, LENGTH, | | | SIZE AND TERMINATION OF THE GAS VENTS PER FBC-2017 FUEL | | | GAS CODE SEC. 502 THRU 505. | | | | | | 4. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT AND REGULATORS TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2017 FUEL GAS SEC. | | | 402.2 | | | | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2017 FUEL GAS CODE SEC. 304. | | | | | | 6. PROVIDE SIZING TABLES USED FOR SIZING SYSTEM . PER | | | FBC FG SEC 402.4 TABLES 402.4(1)- 402.4(37) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-08-27 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-08-27 |
Time |
06:32 |
Sent To |
|
|
| Notes |
| 2019-08-27 06:33:22 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-12-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-11-26 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-11-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-11-19 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-09 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-17 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-09 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-01-13 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-01-13 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-01-13 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2020-01-13 13:10:13 | OK-PLANS STAMPED | | | MU-2020-001188-0000 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-17 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-16 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2019-09-17 10:34:53 | 109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU | | | MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF | | | | | | DYLAN BATTLES | | | 561-805-6718 | | | [email protected] | | | | | | THE CITY OF WEST PALM BEACH | | | BUILDING PLANS EXAMINER PX4191 | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-10-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-10-25 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-10-25 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-09-12 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-09-12 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2019-09-12 10:48:38 | PLAN DENIED | | | MASTER BEDROOM HIS WALK IN CLOSET HAS A RETURN AIR IN | | | IT | | | REFER TO SECTION 1602.2 # 4 RETURN AIR OPENING. RETURN | | | AIR SHALL | | | NOT BE TAKEN FROM A CLOSET 2017 RESIDENTIAL CODE. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
P |
Date |
2019-12-03 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-03 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-03 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2019-12-03 12:27:41 | B.F.E. = 7'-0" NAVD | | | D.F.E. = 9'-0" | | | | | | PRE-CONSTRUCTION ELEVATION CERTIFICATE RECEIVED | | | UNDER CONSTRUCTION (WITH FORMBOARD SURVEY) AND FINAL | | | CONSTRUCTION ELEVATION CERTIFICATE (BEFORE FINAL | | | BUILDING INSPECTION) NEED TO BE PROVIDED TO BUILDING | | | INSPECTOR. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-12-17 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-12-17 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-12-17 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2019-12-17 14:26:48 | PLUMBING COMMENTS: APPROVED | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-10-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-23 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-22 |
Time |
08:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-08-27 |
Time |
06:11 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-08-27 |
Time |
06:11 |
Sent To |
|
|
| Notes |
| 2019-08-27 06:34:08 | 08/27/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2019-12-03 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-03 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-03 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2019-12-03 10:13:53 | PROVIDE ROOFING PRODUCT APPROVALS WITH SUB PERMIT | | | APPLICATION. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-17 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-16 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2019-09-17 10:35:27 | ROOFING SUBMITTAL NEEDED WITH SUB=PERMIT APPLICATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-12-16 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-12-16 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-12-16 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2019-12-16 08:31:08 | PROVISO: A LANDSCAPE PERMIT SHALL BE SUBMITTED AND | | | APPROVED BY THE CITY WITHIN 90 DAYS OF APPROVAL OF | | | BUILDING PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-18 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-11-18 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-11-18 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2019-11-18 17:39:16 | PROVISO: A LANDSCAPE PERMIT SHALL BE SUBMITTED AND | | | APPROVED BY THE CITY WITHIN 90 DAYS OF APPROVAL OF | | | BUILDING PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-09-13 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-09-13 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2019-09-13 13:16:46 | 1. PLEASE PROVIDE A SURVEY OF THE PROPERTY THAT | | | INCLUDES THE TOTAL SQUARE FOOTAGE OF THE SITE. | | | 2. PLEASE PROVIDE A BUILDING DATA TABLE INDICATING THE | | | LOT SQUARE FOOTAGE AND THE SQUARE FOOTAGE OF EACH OF | | | THE FLOORS. ALSO INCLUDE A SMALL SKETCH REFLECTING THE | | | BUILDNG FOOTPRINT FOR EACH FLOOR TO CONFIRM COMPLIANCE | | | WITH SEC 94-129 TABLE IV-40 OF THE ZLDRS. | | | 3. PLEASE INDICATE THE REQUIRED SETBACKS IN THE SITE | | | PLAN AND THE PROPOSED SETBACKS. EXISTING WALLS NOT IN | | | COMPLIANCE WITH THE MINIMUM SETBACK MAY REMAIN BUT | | | PLEASE CLEARLY INDICATE THEY ARE EXISTING WALLS TO | | | REMAIN. | | | 4. PLEASE SUBMTI A SEPARATE LANDSCAPE PERMIT IN | | | COMPLIANCE WITH THE FOLLOWING REGULATIONS: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | GROSS LOT SQUARE FOOTAGE MINUS | | | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR | | | PORTION THEREOF | | | ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR | | | PORTION THEREOF | | | SECTION 94-442 (D) SUBSTITUTION OF PALM TREES. | | | PALM TREES MAY BE SUBSTITUTED FOR NOT MORE THAN 35 | | | PERCENT OF THE SHADE OR FLOWERING TREES REQUIRED BY | | | THIS ARTICLE. HOWEVER, WHEN PALM TREES ARE SUBSTITUTED | | | FOR SHADE TREES, THREE PALM TREES SHALL BE PROVIDED FOR | | | EACH REQUIRED SHADE TREE. THIS 3:1 SUBSTITUTION SHALL | | | NOT BE REQUIRED FOR ROYAL PALM TREES (ROYSTONEA SPP.), | | | SENEGAL DATE PALM (PHOENIX RECLINATA), MEDJOOL DATE | | | PALM (PHOENIX DACTYLIFERA), BISMARCK PALM (BISMARCKIA | | | NOBILIS), AND SILVER DATE PALM (PHOENIX SYLVESTRIS). | | | SECTION 94-442 (G) FLORIDA FRIENDLY LANDSCAPE | | | REQUIREMENTS | | | LANDSCAPE PLAN MUST SATISFY A MINIMUM TOTAL OF 25 | | | POINTS FROM THE DESIGN OPTIONS CHART. | | | SECTION 94-445 (4) REQUIRED PLANT MATERIAL | | | SPECIFICATIONS. | | | SHADE AND FLOWERING TREES MINIMUM 12 FEET IN HEIGHT AND | | | FLORIDA GRADE #1 OR BETTER QUALITY. | | | PALM SPECIES MINIMUM EIGHT FEET CLEAR WOOD. | | | SHRUBS MINIMUM OF 3 GALLON, GROUNDCOVER MAY BE SMALLER. | | | SECTION 94-445 I. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439 |
|
|