| 2019-08-27 13:46:18 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19080441 |
| | ADD: 505 S. FLAGLER DR. |
| | CONT: ANDERSON MOORE CONTRACTING |
| | TEL: 561-348-4805 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. AUGUST 27/ 2019 |
| | ACTION: DENIED |
| | |
| | 1) 002-SITE DEV. PLAN. PLEASE PROVIDE AN EXPLANATION AS |
| | TO WHY THERE IS A NEW DRIVEWAY AND STAIRS BEING CUT |
| | INTO S. FLAGLER DR. WHEN THE ENTRY TO THE BUILDING IS |
| | ON THE WEST FACE OF THE BUILDING? 107.2.1.2 ADDITIONAL |
| | INFORMATION IS REQUIRED. |
| | |
| | 2) 002-SITE DEV. PLAN. IS THIS NEW DRIVE AND STAIRWAY |
| | PART OF A VALET SERVICE OR DOES THE PROPOSED NEW DRIVE |
| | HAVE A DROP OFF ZONE (PASSENGER LOADING ZONE) TO BE |
| | INCORPORATED INTO THE DRIVE? 107.2.1.2 ADDITIONAL |
| | INFORMATION IS REQUIRED. |
| | |
| | 3A) THERE ARE MANY ELEVATION MARKERS ON THE DRIVE PLAN |
| | 002-SITE DEV. PLAN. THE ELEVATION MARKERS DO NOT MAKE |
| | IT CLEAR IF THEY ARE THE TOP OF THE D CURB OR THE TOP |
| | OF THE DRIVEWAY? 107.2.1.2 ADDITIONAL INFORMATION |
| | REQUIRED. PLEASE NOTE DIRECTLY IN FRONT OF THE NEW |
| | STAIR AND LANDING THERE IS A 0.84 FT. CROSS SLOPE DROP |
| | IF THERE IS TO BE A DROP OFF ZONE (PASSENGER LOADING |
| | ZONE)? 2017 FBC-ACCESS. CODE 503.4 SLOPES NOT STEEPER |
| | THAN 1:48 SHALL BE PERMITTED. |
| | |
| | 3B) VEHICLE PULL UP SPACE IS TO COMPLY WITH ACCESS. |
| | CODE REQUIREMENTS 503.2-503.4. |
| | |
| | 4) SHEET 002 SITE DEV. PLAN IF THERE IS NOT A PASSENGER |
| | DROP OFF ZONE, THE PLANS DO NOT STATE THERE IS A |
| | DROPPED CURB AT THE STAIR AND LANDING YOU WOULD HAVE TO |
| | WHEEL A WHEELCHAIR SOUTH OUT INTO THE TRAFFIC LANE FOR |
| | THE PARKING GARAGE TO GET TO THE SIDEWALK. 107.2.1.2. |
| | ADDITIONAL INFORMATION REQUIRED. IT WOULD APPEAR THIS |
| | NEW DRIVEWAY AND STAIR ARE NOT ACCESSIBLE TO THE UPPER |
| | LANDING, IF NOT PLEASE PROVIDE SIGNAGE WHERE THE |
| | ACCESSIBLE ENTRANCE IS LOCATED. PLEASE SHOW COMPLIANCE |
| | WITH: |
| | 2017 FBC-ACCESSIBILITY CODE SECTION 216.6 ENTRANCES. |
| | |
| | WHERE NOT ALL ENTRANCES COMPLY WITH 404, ENTRANCES |
| | COMPLYING WITH 404 SHALL BE IDENTIFIED BY THE |
| | INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH |
| | 703.7.2.1. DIRECTIONAL SIGNS COMPLYING WITH 703.5 THAT |
| | INDICATE THE LOCATION OF THE NEAREST ENTRANCE COMPLYING |
| | WITH 404 SHALL BE PROVIDED AT ENTRANCES THAT DO NOT |
| | COMPLY WITH 404. |
| | |
| | 5) SHEET 002 SITE DEV. PLAN INDICATES THE REMOVAL OF A |
| | PORTION OF A RETAINING WALL. THERE IS ALSO A NOTE |
| | STAIRS BY OTHERS. WHAT IS NOT CLEAR, ARE THE STAIRS TO |
| | BE PART OF SEPARATE PERMIT? THE SHEET 007L1 INDICATES |
| | GRANITE STEP TREADS AND ALUMINUM HANDRAIL BUT NO PLANS |
| | HAVE BEEN SUBMITTED FOR THE STAIR LAYOUT, STEEL |
| | RE-ENFORCING NOR AND INFORMATION ON A HANDRAIL/ |
| | GUARDRAIL SYSTEM. 107.2.1.2 ADDITIONAL INFORMATION IS |
| | REQUIRED. |
| | |
| | 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE |
| | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED |
| | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE |
| | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS |
| | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. |
| | |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |