Plan Review Details - Permit 19080429
Plan Review Stops For Permit 19080429
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-11-25 Cont ID  
Sent By cthroop Date 2019-11-25 Time 14:36 Rev Time 0.00
Received By cthroop Date 2019-11-25 Time 12:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-09-13 Cont ID  
Sent By cthroop Date 2019-09-13 Time 09:04 Rev Time 0.00
Received By cthroop Date 2019-09-12 Time 16:10 Sent To  
Notes
2019-09-13 09:25:07BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE DRAINAGE PLAN.
 FBC R401.3 SITE DRAINAGE
 PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBC R401.3
  
 2. PROVIDE ENERGY SUBMITTAL.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 3. PROVIDE DESIGN PRESSURES FOR ALL WINDOW AND DOOR
 OPENINGS.
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4).
  
 4. DESIGNER SHALL REVIEW AND APPROVE PRODUCT APPROVALS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-11-25 Cont ID  
Sent By jpearson Date 2019-11-25 Time 15:44 Rev Time 0.00
Received By jpearson Date 2019-11-25 Time 15:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-09-05 Cont ID  
Sent By jpearson Date 2019-09-05 Time 09:14 Rev Time 0.00
Received By jpearson Date 2019-08-30 Time 09:09 Sent To  
Notes
2019-09-05 09:14:44CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC
 109.3
 2. LOAD CALCULATION SHOWS A LOAD OF 223 AMPS ON
 SERVICE. RISER DIAGRAM SHOWS DISCONNECT AND PANEL RATED
 FOR 200 AMPS. PROVIDE CORRECTION. NEC 215.2, 408.30,
 408.36; WPB FBC 107.3.5; FBC RE E3602.3
 3. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE
 CORRECTION. NEC 210.12; FBC RE E3902.16
 4. ALL RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS
 SHALL HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8(A)(9); FBC RE E3902.9
 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 6. PROVIDE LOCATION OF ELECTRICAL SERVICE AND
 ELECTRICAL PANELS ON PLAN. WPB FBC 107.2.1
 7. RISER DIAGRAM SHOWS AN EQUIPMENT GROUNDING CONDUCTOR
 (EGC) FROM THE METER CAN TO THE MAIN DISCONNECT. THIS
 CONDUIT SHOULD NOT INCLUDE AN EGC. PROVIDE CORRECTION.
 NEC 250.6; FBC RE E3610.4
 8. RISER DIAGRAM SHOWS (2) 250 KCMIL CONUCTORS FROM
 METER TO MAIN DISCONNECT, AND FROM MAIN DISCONNECT TO
 INTERIOR PANEL. A GROUNDED (NEUTRAL) CONDUCTOR IS
 REQUIRED AT EACH SERVICE DISCONNECT AND WHERE THER ARE
 120 VOLT LOADS. PROVIDE CORRECTION. NEC 250.24(C); FBC
 RE E3607
 9. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM
 BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET
 FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE
 R314.3(4), NFPA 72:29.8.3.4
 10. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14
 11. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE
 PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH
 CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE
 CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-11-08 Cont ID  
Sent By fmittner Date 2019-11-08 Time 13:56 Rev Time 0.00
Received By fmittner Date 2019-11-08 Time 13:56 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-08-29 Cont ID  
Sent By fmittner Date 2019-08-29 Time 09:13 Rev Time 0.00
Received By fmittner Date 2019-08-29 Time 09:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-11-25 Time   Rev Time 0.00
Received By lmarchan Date 2019-11-06 Time 16:09 Sent To  
Notes
2019-11-06 16:09:11R27

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-09-13 Cont ID  
Sent By cthroop Date 2019-09-13 Time 09:27 Rev Time 0.00
Received By cthroop Date 2019-08-08 Time 14:51 Sent To  
Notes
2019-08-09 14:51:52R34

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-12-06 Cont ID  
Sent By cthroop Date 2019-12-06 Time 11:29 Rev Time 0.00
Received By cthroop Date 2019-12-06 Time 11:29 Sent To  
Notes
2019-12-06 11:31:30MU-2019-037549-0000. CT

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-09-13 Cont ID  
Sent By cthroop Date 2019-09-13 Time 09:27 Rev Time 0.00
Received By cthroop Date 2019-09-12 Time 16:10 Sent To  
Notes
2019-09-13 09:28:02PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-11-25 Cont ID  
Sent By cthroop Date 2019-11-25 Time 14:37 Rev Time 0.00
Received By cthroop Date 2019-11-25 Time 12:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-09-09 Cont ID  
Sent By cmontell Date 2019-09-09 Time 14:07 Rev Time 0.00
Received By cmontell Date 2019-09-09 Time 14:04 Sent To  
Notes
2019-09-09 14:07:50MECHANICAL PLAN REVIEW
  
  
 1 - NEED MANUAL J PER 2017 FLORIDA BUILDING CODE -
 RESIDENTIAL SEC M1401.3 EQUIPMENT AND APPLIANCE SIZING.
  
  
 CHRIS MONTELLO
 561-805-6733
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-11-21 Cont ID  
Sent By gjohnson Date 2019-11-21 Time 12:13 Rev Time 0.00
Received By gjohnson Date 2019-11-21 Time 11:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-08-26 Cont ID  
Sent By lcrespo Date 2019-08-26 Time 06:46 Rev Time 0.00
Received By lcrespo Date 2019-08-26 Time 06:39 Sent To  
Notes
2019-08-26 06:46:4608/26/2019 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLUMBING RISER DIAGRAM REQUIRED, CLEAR AND LEGIBLE
 SANITARY RISER DIAGRAM SHALL BE SUBMITTED SHOWING ALL
 PIPE SIZES, CONNECTION POINTS TO EXISTING PIPING, THE
 CONNECTIONS TO THE EXISTING PIPE, AND THE LOCATIONS OF
 REQUIRED CLEANOUTS. WPB AMENDMENTS TO THE FBC SEC.
 107.3.5.3 (11) RESIDENTIAL PLUMBING.
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-11-25 Cont ID  
Sent By cthroop Date 2019-11-25 Time 14:36 Rev Time 0.00
Received By cthroop Date 2019-11-25 Time 12:18 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-09-13 Cont ID  
Sent By cthroop Date 2019-09-13 Time 09:25 Rev Time 0.00
Received By cthroop Date 2019-09-12 Time 16:10 Sent To  
Notes
2019-09-13 09:27:09BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING SUB PERMIT REQUIRED.
 PERMITS
 105.1 REQUIRED.
  
 2. DESIGNER SHALL REVIEW AND APPROVE ROOFING PRODUCT
 APPROVALS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-11-08 Cont ID  
Sent By fmittner Date 2019-11-08 Time 13:56 Rev Time 0.00
Received By fmittner Date 2019-11-08 Time 13:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-08-29 Cont ID  
Sent By fmittner Date 2019-08-29 Time 09:13 Rev Time 0.00
Received By fmittner Date 2019-08-29 Time 09:13 Sent To  
Notes
***NONE***