Plan Review Details - Permit 19080419
Plan Review Stops For Permit 19080419
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-11-21 Cont ID  
Sent By dbattles Date 2019-11-21 Time 14:36 Rev Time 0.00
Received By dbattles Date 2019-11-21 Time 14:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-09-16 Cont ID  
Sent By dbattles Date 2019-09-16 Time 08:17 Rev Time 0.00
Received By dbattles Date 2019-09-13 Time 09:11 Sent To  
Notes
2019-09-16 08:20:14BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19080419
 REVIEWED: SEPTEMBER 16, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1) PROVISOS:
 DEFERRED SUBMITTALS-
 INTERIOR STAIRWAY, RAILS AND GUARDS
 EXTERIOR STAIRWAY RAILS AND GUARDS
 SEPARATE PERMITS REQUIRED FOR-LANDSCAPE, FENCES
 CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO 8PM
 SAT-SUN
 - NO RESPONSE REQUIRED. PROVISOS WILL BE ADDED TO THE
 PLANS AT FINAL STAMPING.
  
 2) 109.3 FBC[AMENDED] PROVIDE COPY OF PROPOSAL WITH
 CONTRACTOR TO SHOW WORK VALUE EQUAL TO THE AMOUNT SHOWN
 ON PERMIT APPLICATION, OR ADJUST VALUE TO MATCH ACTUAL
 COST OF WORK. PLEASE ADJUST FEE AT FRONT DESK.
  
 3) 501.1.1 FBC[RE] ADDITIONS, ALTERATIONS, OR REPAIRS:
 GENERAL. ADDITIONS, ALTERATIONS, OR REPAIRS TO AN
 EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF
 SHALL COMPLY WITH SECTION R502, R503 OR R504. UNALTERED
 PORTIONS OF THE EXISTING BUILDING OR BUILDING SUPPLY
 SYSTEM SHALL NOT BE REQUIRED TO COMPLY WITH THIS CODE.
 - PLEASE PROVIDE DOCUMENTATION TO SUPPORT THE METHOD
 CHOSEN FOR COMPLIANCE.
  
 4) 408.1 FBC[R] PROVIDE VENTING CALCULATIONS FOR UNDER
 FLOOR SPACE, OR FOLLOW REQUIREMENTS FOR UNVENTED.
 - IF ADDITION CRAWL SPACE COMMUNICATES WITH EXISTING
 PLEASE INCLUDE EXISTING IN CALCULATION.
  
 5) 408.4 FBC[R] PROVIDE ACCESS TO THE UNDER FLOOR SPACE
 18X24 MINIMUM.
 - SHOW EXISTING ACCESS, OR PROVIDE ACCESS POINT TO
 FLOOR CRAWL SPACE IF APPLICABLE.
  
 6) 806 FBC[R] SUPPLY VENTING CALCULATIONS FOR THE ATTIC
 AND HOW THE AREA OF VENTING WILL BE ACHIEVED, OR FOLLOW
 R806.5 FOR UNVENTED.
 - PLEASE PROVIDE PRODUCT APPROVAL FOR ROOF INSULATION
 AND ATTACHMENT ACCORDING TO GENERAL LIMITATIONS 7 ON
 NOA 15-0729.18
  
 7) 806.5 FBC[R] UNVENTED ATTIC AND UNVENTED ENCLOSED
 RAFTER ASSEMBLIES. 5.1.2. WHERE AIR-PERMEABLE
 INSULATION IS PROVIDED INSIDE THE BUILDING THERMAL
 ENVELOPE, IT SHALL BE INSTALLED IN ACCORDANCE WITH
 SECTION 5.1.1. IN ADDITION TO THE AIR-PERMEABLE
 INSULATION INSTALLED DIRECTLY BELOW THE STRUCTURAL
 SHEATHING, RIGID BOARD OR SHEET INSULATION SHALL BE
 INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHEATHING
 IN ACCORDANCE WITH THE R-VALUES IN TABLE R806.5 FOR
 CONDENSATION CONTROL.
 - PLEASE REVIEW THIS SECTION FOR AIR PERMEABLE
 INSULATION AT ROOF DECK.
  
 8) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR
 WINDOW MULL AND GARAGE DOORS, OR INDICATE THAT YOU
 WOULD LIKE THEM DEFERRED.
 -
  
 9) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT ATTACHMENT
 FOR ROOF INSULATION, OR INDICATE THAT YOU WOULD LIKE IT
 DEFERRED.
 - ALSO, PROVIDE ENHANCED NAILING ENGINEERED FOR
 EXPOSURE C IN THE 3 WIND ZONES ESTABLISHED ON SHEET
 A-2C. PLEASE PROVIDE PRODUCT APPROVAL FOR ROOF
 INSULATION AND ATTACHMENT ACCORDING TO GENERAL
 LIMITATIONS 7 ON NOA 15-0729.18
  
 10) 107.2.1.2 FBC[AMENDED] SUBMIT TWO SETS OF SHOP
 DRAWINGS FOR STAIRCASE, APPROVED BY DESIGNER OF RECORD,
 FOR REVIEW BY WPB BUILDING DEPARTMENT AS A SUBMITTAL.
  
 NOTES:
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-01-09 Cont ID  
Sent By jpearson Date 2020-01-09 Time 14:17 Rev Time 0.00
Received By jpearson Date 2020-01-09 Time 14:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-12-09 Cont ID  
Sent By jpearson Date 2019-12-09 Time 15:41 Rev Time 0.00
Received By jpearson Date 2019-12-09 Time 14:31 Sent To  
Notes
2019-12-09 15:15:19CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC
 109.3 (NOT PROVIDED.)
 2. CORRECTED.
 3. CORRECTED.
 4. RISER DIAGRAM SHOWS A 225 AMP DISCONNECT AND PANEL
 FOR MAIN HOUSE. THE WIRE SIZE SHOWN FEEDING THESE ITEMS
 IS 2/0. THIS WIRE SIZE IS NOT RATED FOR A 225 AMP
 SERVICE. PROVIDE CORRECTION. NEC 310.15(B)(7) AND
 (B)(16); FBC RE E3603.1, E3705.1 (THE RISER NOW SHOWS A
 200 AMP DISCONNECT TO THE MAIN HOUSE, BUT THE WIRE IS
 STILL TOO SMALL. 2/0 WIRE IS ONLY RATED FOR 175 AMPS,
 UNLESS THE EXCEPTION IN NEC 310.15(B)(7) APPLIES, WHICH
 IN THIS CASE IT DOES NOT. PROVIDE CORRECTION.)
 5. CORRECTED.
 6. CORRECTED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-08-30 Cont ID  
Sent By jpearson Date 2019-08-30 Time 11:01 Rev Time 0.00
Received By jpearson Date 2019-08-30 Time 09:09 Sent To  
Notes
2019-08-30 10:32:39CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC
 109.3
 2. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS
 PERMITTED. PROVIDE CORRECTION AND/OR CLARIFICATION. WPB
 FBC 107.2.1; NEC 230.2; FBC RE E3601.2
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3
 4. RISER DIAGRAM SHOWS A 225 AMP DISCONNECT AND PANEL
 FOR MAIN HOUSE. THE WIRE SIZE SHOWN FEEDING THESE ITEMS
 IS 2/0. THIS WIRE SIZE IS NOT RATED FOR A 225 AMP
 SERVICE. PROVIDE CORRECTION. NEC 310.15(B)(7) AND
 (B)(16); FBC RE E3603.1, E3705.1
 5. LIGHTING IN CLOSETS APPEARS TO BE STANDARD RECESS
 LIGHTS. PER CODE, LIGHTING WITH OPEN OR PARTIALLY
 ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS
 SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. PROVIDE
 CORRECTION. NEC 410.16; FBC RE E4003.12
 6. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE
 SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC
 410.10(D); FBC RE E4003.11
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2019-08-26 Cont ID  
Sent By lcrespo Date 2019-08-26 Time 07:16 Rev Time 0.00
Received By lcrespo Date 2019-08-26 Time 07:16 Sent To  
Notes
2019-08-26 07:18:57GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE. AT
 THIS TIME. WPB AMENDMENTS TO FBC SEC. 107.2.1.

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-11-25 Cont ID  
Sent By fmittner Date 2019-11-25 Time 16:24 Rev Time 0.00
Received By fmittner Date 2019-11-25 Time 16:24 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-08-29 Cont ID  
Sent By fmittner Date 2019-08-29 Time 09:27 Rev Time 0.00
Received By fmittner Date 2019-08-29 Time 09:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2020-01-09 Time   Rev Time 0.00
Received By lmarchan Date 2019-12-27 Time 13:13 Sent To  
Notes
2019-12-27 13:13:06R38

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-12-10 Cont ID  
Sent By hmoser Date 2019-12-10 Time 10:38 Rev Time 0.00
Received By hmoser Date 2019-11-15 Time 15:23 Sent To  
Notes
2019-12-09 17:31:30TO HM DESK
  
2019-11-18 15:23:55R37

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-09-16 Cont ID  
Sent By dbattles Date 2019-09-16 Time 08:20 Rev Time 0.00
Received By dbattles Date 2019-08-08 Time 14:49 Sent To  
Notes
2019-08-09 14:49:43R33

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-01-30 Cont ID  
Sent By dbattles Date 2020-01-30 Time 14:15 Rev Time 0.00
Received By dbattles Date 2020-01-30 Time 14:15 Sent To  
Notes
2020-01-30 14:16:44MU 2020-002693-0000
 NO FEES PAID
 PLANS STAMPED - OK

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-09-13 Cont ID  
Sent By dbattles Date 2019-09-13 Time 14:13 Rev Time 0.00
Received By dbattles Date 2019-09-13 Time 09:11 Sent To  
Notes
2019-09-13 14:14:26109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU
 MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-01-03 Cont ID  
Sent By cmontell Date 2020-01-03 Time 14:29 Rev Time 0.00
Received By cmontell Date 2020-01-03 Time 14:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-12-10 Cont ID  
Sent By hmoser Date 2019-12-10 Time 10:36 Rev Time 0.00
Received By hmoser Date 2019-12-10 Time 10:36 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-09-09 Cont ID  
Sent By cmontell Date 2019-09-09 Time 13:17 Rev Time 0.00
Received By cmontell Date 2019-09-09 Time 13:25 Sent To  
Notes
2019-09-09 13:26:51MECHANICAL PLAN REVIEW FAIL
  
 1 - NEED MANUAL J OR OTHER APPROVED HEATING AND COOLING
 CALCULATION METHODOLOGIES. PER 2017 FLORIDA BUILDING
 CODE - RESIDENTIAL SEC M1401.3 EQUIPMENT AND APPLIANCE
 SIZING.
  
 CHRIS MONTELLO
 561-805-6733

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2020-01-21 Cont ID  
Sent By dbattles Date 2020-01-21 Time 08:48 Rev Time 0.00
Received By dbattles Date 2020-01-21 Time 08:48 Sent To  
Notes
2020-01-21 08:50:02ELEVATION CERTIFICATE RECEIVED.
 BFE WITH FREEBOARD = 8' NAVD
 PROPOSED BFE 8.55' NAVD

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2020-01-16 Cont ID  
Sent By dbattles Date 2020-01-13 Time 14:16 Rev Time 0.00
Received By dbattles Date 2020-01-13 Time 14:16 Sent To  
Notes
2020-01-13 14:27:40THIS PROJECT IS A SUBSTANTIAL IMPROVEMENT AND WE WILL
 NEED AN ELEVATION CERTIFICATE TO SHOW THE ADDITION
 FINISHED FLOOR AT OR ABOVE 8' NAVD.
 THE EXISTING SURVEY SHOWS FLOOR AT 8.55 NAVD SO THERE
 SHOULD BE NO PROBLEM TO COMPLY WITH FLOOD ZONE
 ORDINANCES IF THE FLOOR OF ADDITION MATCHES THE
 EXISTING.
  
 THE INITIAL ELEVATION CERTIFICATE CAN BE E-MAILED TO ME
 SO THE PERMIT CAN BE ISSUED.
 HOWEVER, THE FINAL CONSTRUCTION ELEVATION CERTIFICATE
 NEEDS TO BE ORIGINAL.
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE CITY OF WEST PALM BEACH
 BUILDING PLANS EXAMINER PX4191
  
 SUBSTANTIAL IMPROVEMENT REVIEW
 ONLY THE PROPOSED RENOVATION AND DEMO
 $35,000.00 19051565 DEMO PERMIT
 $62,000.00 19080419 RENOVATION
 $97,000.00 / 189,116.00 = 51%
  
 BFE=6' NAVD +2' FREEBOARD = 8' NAVD
 ALL EXISTING AND NEW WORK IS ABOVE BFE.
 CONFIRMED SURVEY SHOWS AT 8.55' NAVD
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-01-07 Cont ID  
Sent By jesmith Date 2020-01-07 Time 13:47 Rev Time 0.00
Received By jesmith Date 2020-01-07 Time 12:02 Sent To  
Notes
2020-01-07 13:47:15PLUMBING COMMENTS: APPROVED; SEE PROVISOS ON MP-1 AND
 MP-1C
  
 1. A BACKFLOW DEVICE (REDUCED PRESSURE ZONE PRINCIPAL
 BACKLFOW ASSEMBLY) MAY BE REQUIRED PER CITY OF WEST
 PALM BEACH UTILITIES DEPARTMENT CROSS CONNECTION MANUAL
 AND ORD #2853-95, PLEASE CALL 561-822-2240 FOR MORE
 INFORMATION SINCE THIS IS A DUAL DWELLING.
 2. A SEPARATE GAS PLAN REVIEW WILL BE REQUIRED A GAS, A
 GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS AND GAS RISER THAT REFLECTS THE
 ENTIRE SCOPE OF GAS WORK TO BE DONE AT THIS TIME PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
 3. PER FBC RES P3114.5, ACCESS SHALL BE PROVIDED TO AIR
 ADMITTANCE VALVES. SUCH VALVES SHALL BE INSTALLED IN A
 LOCATION THAT ALLOWS AIR TO ENTER THE VALVE.
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-12-09 Cont ID  
Sent By tklarge Date 2019-12-09 Time 12:10 Rev Time 0.00
Received By tklarge Date 2019-12-09 Time 11:50 Sent To  
Notes
2019-12-09 12:10:121) SHTS. D-1, A-1, A-2, A1C, & A-2C DO NOT BEAR THE
 SEAL OF THE DESIGN PROFESSIONAL AS REQUIRED BY FL.
 ADMIN. CODE RULE 61G1--16.001. PLEASE SEAL THE
 AFOREMENTIONED SHEETS.
 2) SHOW THE LOCATION OF THE TANKLESS WATER HEATER FOR
 THE MAIN HOUSE ON THE ARCHITECTURAL PLANS. THE TANKLESS
 WATER HEATER IS USUALLY REQUIRED TO BE A MINIMUM OF 48
 INCHES FROM ANY OPERABLE DOOR, WINDOW OR BUILDING
 OPENING INCLUDING SOFFIT VENTS PER THE MANUFACTURER'S
 INSTALLATION MANUAL.
 3) SIZE ALL THE DRAINAGE LINES AND VENT LINES ON ALL
 RISER DIAGRAMS. WPB AMEND. TO FBC SEC. 107.2.1.
 4) MASTER BATH SANITARY RISER - THE TUB, WATER CLOSET
 AND SHOWER ARE NOT VENTED. 2017 FBCR SEC. P3101.2,
 P3108.1.
 5) ACCESS SHALL BE PROVIDED TO THE SHUTOFF VALVES FOR
 THE WASHING MACHINE. 2017 FBCR SEC. P2903.9.3.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-08-26 Cont ID  
Sent By lcrespo Date 2019-08-26 Time 15:51 Rev Time 0.00
Received By lcrespo Date 2019-08-26 Time 06:51 Sent To  
Notes
2019-08-26 15:51:1908/26/2019 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON RISER DIAGRAM MP-1 FIRST FLOOR GUEST BATH SHOWER
 LABELED AS LAV AND LAV NOT LABELED PLEASE MAKE CHANGES,
 WPB AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11)
 RESIDENTIAL PLUMBING.
  
 2. BATH 2 SHOWER IS NOT VENTED CORRECTLY, WET VENT
 REQUIRED BETWEEN WATER CLOSET AND SHOWER, WPB
 AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL
 PLUMBING.
  
 3. BATH 3 DIAGRAM HAS A WASHING MACHINE ON A 2" DRAIN,
 PER MANUFACTURE SPECIFICATION ON MOST UNITS REQUIRE A
 3" DRAIN LINE, PLEASE SUBMIT SPECS ON WASHING MACHINE
 OR MAKE CHANGES ON PIPE SIZE, WPB AMENDMENTS TO THE FBC
 SEC. 107.3.5.3 (11) RESIDENTIAL PLUMBING.
  
 4. SANITARY RISER DIAGRAM MC-1C FOR CABANA BATH FIRST
 FLOOR STACK TO THE SECOND FLOOR MUST BE ON ITS OWN
 SYSTEM AND CANNOT VENT ON STACK, NEED KITCHEN ON ITS
 OWN STACK AND LAV ON ITS OWN BATHROOM GROUP, WILL NEED
 A AIR ADMITTANCE OR A VENT THROUGH ROOF FOR KITCHEN AND
 BATHROOM GROUP DOWNSTAIRS, WPB AMENDMENTS TO THE FBC
 SEC. 107.3.5.3 (11) RESIDENTIAL PLUMBING.
  
 5. SANITARY RISER DIAGRAM MC-1C FOR CABANA BATH SECOND
 FLOOR WAS LABELED AS 1ST FLOOR PLEASE CHANGE TO 2ND
 FLOOR AND WASHING MACHINE STACK MUST BE 3" (REFER TO
 COMMENT 3), SHOWER NEEDS WET VENT BETWEEN WC AND
 SHOWER, PLEASE CHANGE, WPB AMENDMENTS TO THE FBC SEC.
 107.3.5.3 (11) RESIDENTIAL PLUMBING.
  
 6. A BACKFLOW DEVICE (REDUCED PRESSURE ZONE PRINCIPAL
 BACKLFOW ASSEMBLY) MAY BE REQUIRED PER CITY OF WEST
 PALM BEACH UTILITIES DEPARTMENT CROSS CONNECTION MANUAL
 AND ORD #2853-95, PLEASE CALL 561-822-2240 FOR MORE
 INFORMATION SINCE THIS IS A DUAL DWELLING.
  
 7. A SEPARATE GAS PLAN REVIEW WILL BE REQUIRED A GAS, A
 GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS AND GAS RISER THAT REFLECTS THE
 ENTIRE SCOPE OF GAS WORK TO BE DONE AT THIS TIME PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 8. SHOWER PAN DETAIL REFERS TO PLB 471.5.2 WHICH IS NOT
 THE RESIDENTIAL CODE 2017 FBC RES. SEC 2709.2 LINING
 REQUIRED, PLEASE REVISE TO REFLECT RESIDENTIAL CODE,
 WPB AMENDMENTS TO THE FBC SEC. 107.2.1.4 QUALITY OF
 BUILDING PLANS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2019-09-16 Cont ID  
Sent By dbattles Date 2019-09-16 Time 08:17 Rev Time 0.00
Received By dbattles Date 2019-09-13 Time 09:11 Sent To  
Notes
2019-09-16 08:18:40SEE BUILDING COMMENTS 6,7 AND 9.

Review Stop Z ZONING
Rev No 2 Status P Date 2019-11-25 Cont ID  
Sent By fmittner Date 2019-11-25 Time 16:24 Rev Time 0.00
Received By fmittner Date 2019-11-25 Time 16:24 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-08-29 Cont ID  
Sent By fmittner Date 2019-08-29 Time 09:27 Rev Time 0.00
Received By fmittner Date 2019-08-29 Time 09:27 Sent To  
Notes
***NONE***