| 2019-08-22 11:10:57 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| | MANUAL REVISED 2017 |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | NFPA 54 = NATIONAL FUEL GAS CODE |
| | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE |
| | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE |
| | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 |
| | NFPA 99 = HEALTH CARE FACILITIES CODE |
| | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | |
| | 1ST REVIEW |
| | PLUMBING COMMEMTS: DENIED |
| | 1.PER WPB FBC 107.2.1, PROVIDE ON THE DEMO PLAN, |
| | ORIGINAL CONFIGURATIONS OF FIXTURES AND APPLIANCES IN |
| | THE KITCHEN AND IN THE BATHROOMS BEING REMODELED. |
| | 2.RE: P-1 SANITARY RISER DIAGRAM AND PLAN VIEW PIPING, |
| | SEE THE FOLLOWING AND CORRECT. |
| | 3. WITH THE EXCEPTION OF THE VENT FOR THE WASHER, ALL |
| | OF THE VENTS TO THE EXTERIOR SHOWN ON THE SANITARY |
| | PIPING DIAGRAMS (RISER AND PLAN VIEW) DO NOT COMPLY |
| | WITH THE REQUIREMENTS OF FBC RES P3104.3 (VENT |
| | CONNECTION TO DRAINAGE SYSTEM. A DRY VENT CONNECTING TO |
| | A HORIZONTAL DRAIN SHALL CONNECT ABOVE THE CENTERLINE |
| | OF THE HORIZONTAL DRAIN PIPE.) AND FBC RES P3104.4 |
| | (VERTICAL RISE OF VENT. A DRY VENT SHALL RISE |
| | VERTICALLY TO NOT LESS THAN 6 INCHES ABOVE THE FLOOD |
| | LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE BEING |
| | VENTED.) |
| | 4. PER FBC RES 3108.1, THE BATHTUB SHALL NOT BE VENTED |
| | BY THE WASHER. THE BATHTUB FIXTURE DRAIN SHALL CONNECT |
| | TO THE HORIZONTAL WET VENT OR BE INDIVIDUALLY VENTED IN |
| | ACCORDANCE WITH FBC RES 3105 AND P3601.1. |
| | 5. PER FBC RES P3108.1, THE SHOWER DRAIN IN BATHROOM #1 |
| | SHALL NOT CONNECT TO THE WATER CLOSET DRAIN AHEAD OF |
| | THE VENT. EACH FIXTURE DRAIN SHALL CONNECT |
| | INDEPENDENTLY TO THE WET VENT OR SHALL HAVE A DRY VENT |
| | CONFORMING TO FBC RES P3104.3 AND P3104.4. |
| | 6. PER FBC RES 3105.2 AND P3201.5(3), PROVIDE VENT AT |
| | THE POINT WHERE THE TRAPPED FIXTURE DRAIN GOES FROM |
| | HORIZONTAL TO VERTICAL (SEE ALL VANITIES AND SINKS). |
| | 7. GENERAL NOTE: PLEASE REFER TO FBC RES SECTION 3108 |
| | WET VENTING WHEN DESIGNING THE BATHROOM DRAINAGE, WASTE |
| | AND VENTS. ADDITIONALLY, THE USE OF AIR ADMITTANCE |
| | VALVES IN LIEU OF VENTS TO THE EXTERIOR IS PERMITTED |
| | (SEE FBC RES P3104.1, EXCEPTION) AS LONG AS A MINIMUM |
| | OF ONE (1) VENT PER BUILDING DRAIN(YOU HAVE TWO (2) |
| | BUILDING DRAINS) EXTENDS TO THE EXTERIOR (SEE FBC RES |
| | P3102.1). |
| | 8. AS THE PLANS ARE NOT SIGNED AND SEALED BY A |
| | PROFESSIONAL ENGINEER OR ARCHITECT, THE PLUMBING PLAN |
| | SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE |
| | DESIGNER PER WPB FBC 107.2.1. |
| | |
| | |
| | END OF COMMENTS. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | AS THE PLANS ARE NOT SIGNED AND SEALED BY A |
| | PROFESSIONAL ENGINEER OR ARCHITECT, THE PLUMBING PLAN |
| | SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE |
| | DESIGNER PER WPB FBC 107.2.1. |
| | |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | PHONE 561-805-6715 |
| | |
| | 19080405 140 MONROE DR |
| | |