| Plan Review Stops For Permit 19080390 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-08-27 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-08-27 |
Time |
09:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-08-27 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-08-27 |
Time |
09:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-10-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-10-01 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-10-01 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2019-09-27 16:10:23 | SIGNATURES MOVED TO LARGE DENIED TBD6. LEM | | 2019-09-26 15:31:58 | DIGITAL SIGNATURES IN LIBRARY FOR ELECTRICAL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-08-26 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-08-23 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2019-08-26 07:55:30 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) NEED TO SUBMIT A RISER DIAGRAM PER 215.5 | | | | | | 2) NEED TO SUBMIT PANEL SCHEDULE(S) | | | | | | 3) NEED TO COMPLY WITH THE ENERGY CODE FOR LIGHTING | | | CONTROL AND RECEPTACLE CONTROL | | | | | | 4) NEED TO SUBMIT A LOAD CALCULATION PER ARTICLE 220 OF | | | THE NEC. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-08-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-08-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-08-12 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-10-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-10-01 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-09-25 |
Time |
08:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-09-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-09-11 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-08-08 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-09-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-09-11 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-09-11 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-08-27 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-08-20 |
Time |
19:39 |
Sent To |
|
|
| Notes |
| 2019-08-27 07:55:19 | REVIEWED BY TIM HUNT: | | | NO PLUMBING WORK IS SHOWN ON THE PLANS. SEPARATE | | | PERMIT, APPLICATION AND REVIEW IS REQUIRED FOR | | | PLUMBING. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-10-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-10-01 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-10-01 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2019-09-26 15:32:14 | DIGITAL SIGNATURES IN LIBRARY FOR ELECTRICAL |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-09-13 |
Time |
05:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-09-13 |
Time |
05:16 |
Sent To |
|
|
| Notes |
| 2019-08-27 09:35:12 | ARCHITECTURAL PLANS REVIEWED FOR DIFITAL SIGNATURE. JW | | | 8/27/2019 |
|
|