Plan Review Details - Permit 19080122
| Plan Review Stops For Permit 19080122 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-09-27 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-09-27 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-24 |
Time |
07:00 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-24 |
Time |
07:00 |
Sent To |
|
|
| Notes |
| 2019-09-24 07:00:08 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. NO ELECTRICAL ISSUES, BUT PLAN CANNOT BE STAMPED | | | UNTIL THE SIGNATURE ISSUE IS RESOLVED. PROVIDE | | | CORRECTION. WPB FBC 107.1, 107.2.1; FS 471/481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-08-11 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-08-11 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-08-11 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2019-08-11 08:56:43 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE CUT SHEETS FOR PRODUCT APPROVAL SHOWING UL | | | OR ORTHER NRTL LISTINGS OF ALL MATERIALS AND EQUIPMENT | | | TO BE USED ( RFID ANTENNA AND RFID READER) FBC 107.2.1 | | | NEC 90.7, 110.2, 110.3B | | | | | | 2. DOCUMENT HAS AN ENGINEER'S SEAL AND SIGNATURE BUT IT | | | NOT DIGITALLY SIGNED. PLAN SAYS DRAWN BY "CDH" CHECKED | | | BY "BMM". | | | | | | ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND | | | SIGNED/SEALED BY A DESIGN PROFESSIONAL OR THE | | | ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | | 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-09-27 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-09-24 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2019-09-25 11:19:29 | HARD COPIES ROUTED TO JPEARSON'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-09-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-09-17 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-08-11 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-08-11 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-08-05 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-09-27 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-09-27 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-24 |
Time |
06:58 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-24 |
Time |
06:58 |
Sent To |
|
|
| Notes |
| 2019-09-24 06:58:35 | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A | | | DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY | | | VERIFICATION. SELF-CERTIFICATION IS NOT ACCEPTABLE FOR | | | ENGINEERS. ADDITIONALLY, THE DIGITAL SIGNATURE MUST | | | INCLUDE THE STATEMENT "SIGNED AND SEALED" AS PER FAC | | | 61G15-23.004. PROVIDE CORRECTION. WPB FBC 107.1; FS | | | 471/481 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-08-11 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-08-11 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-08-11 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2019-08-11 09:03:38 | DOCUMENT HAS A SIGNATURE AND SEAL FROM AN ENGINEER BUT | | | IS NOT DIGITALLY SIGNED. PLAN SAYS DRAWN BY "CDH" | | | CHECKED BY "BMM" | | | | | | | | | ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND | | | SIGNED/SEALED BY A DESIGN PROFESSIONAL OR THE | | | ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | | 471.003(2)(H); 471.025; WPB FBC 107.1 |
|
|
|