| Plan Review Stops For Permit 19080055 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-11-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-11-12 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-11-12 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2019-11-12 09:58:28 | PROVISO: | | | 107.3.4.1 FBC[AMENDED] SUBMIT TRUSS SHOP DRAWINGS TO | | | THE BUILDING INSPECTOR PRIOR TO INSTALLATION. | | 2019-10-04 14:45:52 | BUILDING PLANS EXAMINER, PLEASE EVALUATE EXPIRED | | | PERMITS AND COMMUNICATE EACH STATUS TO OWNER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-09-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-09 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-09 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2019-09-09 15:54:22 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19080055 | | | REVIEWED: SEPTEMBER 9, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[B] = FBC BUILDING | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | FBC[R] = FBC RESIDENTIAL | | | | | | 1) 107.5.3 FBC[AMENDED]THE TWO SETS OF DRAWINGS | | | PROVIDED DO NOT MATCH. ONE SET INCLUDES REVISIONS AND | | | THE OTHER DOES NOT. | | | ALSO, SHEET S4 IS MISSING FROM THE SET WITHOUT | | | REVISIONS. | | | I?M REVIEWING THE SET WITH REVISIONS. | | | | | | 2) 501.1.1 FBC[RE] ADDITIONS, ALTERATIONS, OR REPAIRS: | | | GENERAL. ADDITIONS, ALTERATIONS, OR REPAIRS TO AN | | | EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF | | | SHALL COMPLY WITH SECTION R502. UNALTERED PORTIONS OF | | | THE EXISTING BUILDING OR BUILDING SUPPLY SYSTEM SHALL | | | NOT BE REQUIRED TO COMPLY WITH THIS CODE. | | | -PLEASE CHOOSE METHOD (R502.1.1, R502.1.2 OR | | | R502.1.3)AND SUPPLY DOCUMENTAION TO COMPLY WITH THE | | | METHOD CHOOSEN. | | | | | | 3) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR | | | WINDOWS, MULL BAR AND DOORS W/SIDELITES IN ADDITION, OR | | | INDICATE THAT YOU WOULD LIKE IT DEFERRED. | | | | | | 4) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR | | | TILE ROOFING AND ADHESIVE, OR INDICATE THAT YOU WOULD | | | LIKE IT DEFERRED. | | | | | | 5) 107.3.4.1 FBC[AMENDED] SUBMIT TRUSS SHOP DRAWINGS TO | | | THE BUILDING INSPECTOR PRIOR TO INSTALLATION. | | | - THE TRUSS SUBMITTAL CAN BE APPROVED NOW IF PUT IN | | | SUPPORTING DOCUMENTS AS A SUBMITTAL, OR IT CAN BE | | | DEFERRED. IF DEFERED THE TRUSS PACKAGE NEEDS TO BE | | | REVIEWED BY BUILDING INSPECTOR PRIOR TO INSTALLATION. | | | | | | NOTES: | | | | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-12-03 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-12-03 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-12-03 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-11-05 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-11-05 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-11-05 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2019-11-05 11:49:22 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RISER DIAGRAM SHOWS #1 WIRE FEEDING A 200 AMP | | | DISCONNECT AND PANEL. THIS WIRE IS NOT RATED FOR200 | | | AMPS. IN ADDITION, THE LOAD CALCULATION SHOWS A LOAD OF | | | 170 AMPS. THE #1 WIRE IS RATED FOR 130 AMPS. PROVIDE | | | CORRECTION. NEC 310.15(B)(16); FBC RE E3603.1, E3705.1 | | | 2. RISER DIAGRAM SHOWS A # 8 EQUIPMENT GROUNDING | | | CONDUCTOR IN THE FEED FOR THE 200 AMP PANEL. THIS WIRE | | | IS NOT SIZED PROPERLY, PROVIDE CORRECTION. NEC 250.122; | | | FBC RE E3704.6, 3607.3.1 | | | 3. OK | | | 4. RISER DIAGRAM DOES NOT SHOW THE WIRE SIZE TO THE 60 | | | AMP DISCONNECT. PROVIDE CORRECTION. NEC 215.5; FBC RE | | | E3706.1, E3608.1, E3609.3; WPB FBC 107.2.1 | | | 5. RISER DIAGRAM INDICATES THE 60 AMP DISCONNECT WILL | | | BE FED FROM THE DUAL LUGS IN THE METER CAN. HOWEVER, | | | THE LOAD IS SHOWN AS PART OF THE MAIN. WHERE IS THIS | | | PANEL FED FROM? PROVIDE CLARIFICAITONS AND CORRECTIONS. | | | WPB FBC 107.2.1 | | | 6. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | 7. THE MECHANICAL PLAN SHOWS THE NEW ROOM AS A DINING | | | ROOM. IF SO, THE RECEPTACLE OUTLETS IN THIS ROOM ARE | | | REQUIRED TO BE ON A SMALL APPLIANCE BRANCH CIRCUIT WITH | | | A 20 AMP RATING AND WIRE SIZE. PROVIDE CORRECTION. NEC | | | 210.52(B)(2); FBC RE E3703.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-08-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-08-21 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-08-21 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2019-08-21 13:59:38 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RISER DIAGRAM SHOWS #1 WIRE FEEDING A 200 AMP | | | DISCONNECT AND PANEL. THIS WIRE IS NOT RATED FOR200 | | | AMPS. IN ADDITION, THE LOAD CALCULATION SHOWS A LOAD OF | | | 170 AMPS. THE #1 WIRE IS RATED FOR 130 AMPS. PROVIDE | | | CORRECTION. NEC 310.15(B)(16); FBC RE E3603.1, E3705.1 | | | 2. RISER DIAGRAM SHOWS A # 8 EQUIPMENT GROUNDING | | | CONDUCTOR IN THE FEED FOR THE 200 AMP PANEL. THIS WIRE | | | IS NOT SIZED PROPERLY, PROVIDE CORRECTION. NEC 250.122; | | | FBC RE E3704.6, 3607.3.1 | | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 | | | 4. RISER DIAGRAM DOES NOT SHOW THE WIRE SIZE TO THE 60 | | | AMP DISCONNECT. PROVIDE CORRECTION. NEC 215.5; FBC RE | | | E3706.1, E3608.1, E3609.3; WPB FBC 107.2.1 | | | 5. RISER DIAGRAM INDICATES THE 60 AMP DISCONNECT WILL | | | BE FED FROM THE DUAL LUGS IN THE METER CAN. HOWEVER, | | | THE LOAD IS SHOWN AS PART OF THE MAIN. WHERE IS THIS | | | PANEL FED FROM? PROVIDE CLARIFICAITONS AND CORRECTIONS. | | | WPB FBC 107.2.1 | | | 6. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | 7. THE MECHANICAL PLAN SHOWS THE NEW ROOM AS A DINING | | | ROOM. IF SO, THE RECEPTACLE OUTLETS IN THIS ROOM ARE | | | REQUIRED TO BE ON A SMALL APPLIANCE BRANCH CIRCUIT WITH | | | A 20 AMP RATING AND WIRE SIZE. PROVIDE CORRECTION. NEC | | | 210.52(B)(2); FBC RE E3703.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
P |
Date |
2019-12-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-12 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-12 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2019-12-12 09:59:11 | OK-PLANS STAMPED | | | MU-2019-038543-0000 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-12-03 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-12-03 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-11-19 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2019-11-20 14:15:48 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-11-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-11-12 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-10-21 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-09-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-09 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-01 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-12-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-12 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-12 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-09-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-09 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-09 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-08-23 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-08-23 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2019-11-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-11-12 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-11-12 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2019-11-12 10:07:25 | PROVIDE PRODUCT APPROVAL FOR ROOF TILE ATTACHMENT. | | | TILE AND SEAL APPROVED PER PRODUCT APPROVALS BELOW: | | | NOA 18-0829.02 AND NOA 18-0502.03 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-09-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-09 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-09 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2019-09-09 15:36:08 | SEE BUILDING COMMENT FOR ROOFING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-11-21 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-11-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-11-21 |
Time |
|
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-10-29 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-10-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-10-29 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-29 09:11:36 | *************************ZONING REVIEW | | | FAILED********************* | | | | | | PLEASE PROVIDE A COPY OF SURVEY OF PROPRETY. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-08-12 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-08-12 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2019-08-12 |
Time |
|
Sent To |
|
|
| Notes |
|
|