Plan Review Details - Permit 19071622
| Plan Review Stops For Permit 19071622 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-08-27 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-08-27 |
Time |
12:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-08-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-08-19 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-07-31 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-08-27 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-08-27 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2019-08-27 12:02:31 | PLUMBING COMMEMTS: APPROVED W/PROVISO | | | ON P4.0, SANITARY RISER, CONNECT THE FLOOR DRAIN TO THE | | | WET VENT AHEAD OF THE WATER CLOSET (SEE RED LINED | | | COMMENT AND MARK UPS ON P4.0) AS SHOWN ON P1.0 PLAN | | | VIEW. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-08-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-08-19 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-08-19 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2019-08-19 09:52:51 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. P4.0 THE SANITARY ISOMETRIC IS TO CONGESTED TO | | | DETERMINE CODE COMPLIANCE PLEASE CORRECT THE FOLLOWING: | | | ENLARGE DRAWING, THE BRANCH DRAIN FOR THE TOILET FLOOR | | | DRAIN AND LAVATORY CONNECT TO MULTIPLE POINTS ALONG THE | | | BUILDING DRAIN AND TO EACH OTHER THEY SHALL ONLY | | | CONNECT ONCE. THE DIRECTION OF FLOW ON THE TOILET | | | BRANCH IS OPPOSITE OF THE OTHER PIPING. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | 2. THE WATER FOUNTAIN SHALL NOT CONNECT TO THE WET VENT | | | OF THE BATHROOM GROUP. PER FBC PL 912.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-08-27 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-08-27 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2019-08-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-08-19 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-08-19 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2019-08-19 09:55:40 | ANY REVISED SHEETS SHALL BE DIGITALLY SIGNED AND | | | SEALED. |
|
|
|