Plan Review Details - Permit 19071543
Plan Review Stops For Permit 19071543
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-10-15 Cont ID  
Sent By jwitmer Date 2019-10-15 Time 10:45 Rev Time 0.00
Received By jwitmer Date 2019-10-15 Time 10:36 Sent To  
Notes
2019-10-15 10:45:492017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19071543
 ADD: 3200 N CONGRESS AVE.
 CONT: BUDGET FENCE & GATE SYSTEMS
 TEL: 561-793-6404
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. OCT. 15, 2019
 ACTION: BUILDING PROVISO
  
 1) FUTURE OPERATORS WILL REQUIRE A SEPARATE PERMIT AND
 WILL NEED TO SHOW COMPLIANCE WITH 2017 FBC-B SECTION
 3110.4 VEHICULAR GATE OPENERS. VEHICULAR GATE OPENERS,
 WHERE PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL
 325.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-08-20 Cont ID  
Sent By jwitmer Date 2019-08-20 Time 10:01 Rev Time 0.00
Received By jwitmer Date 2019-08-20 Time 09:41 Sent To  
Notes
2019-08-20 09:42:062017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19071543
 ADD: 3200 N CONGRESS AVE.
 CONT: BUDGET FENCE & GATE SYSTEMS
 TEL: 561-793-6404
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. AUGUST 20, 2019
 ACTION: DENIED
  
 1) THE SUBMITTED PERMIT IS FOR 2 DOUBLE SWING GATES, 1
 SINGLE ALUMINUM GATE AND 5 CONCRETE PADS FOR FUTURE
 OPERATORS. THE ONLY INFORMATION SUBMITTED FOR THESE
 GATES IS A SURVEY WITH THE LOCATION OF THE GATES AND
 PADS FOR FUTURE OPERATORS. THERE IS INSUFFICIENT
 INFORMATION TO DO A PLAN REVIEW ON THE AUTOMATIC
 VEHICULAR GATE SYSTEM. THE GATES WILL NEED TO SHOW
 COMPLIANCE WITH THE 2017 FBC-B SECTION
 3110.3. VEHICULAR GATES INTENDED FOR AUTOMATION SHALL
 BE DESIGNED, CONSTRUCTED AND INSTALLED TO COMPLY WITH
 THE REQUIREMENTS OF ASTM F2200.
  
 PLEASE PROVIDE DETAILED DRAWINGS SHOWING HOW COMPLIANCE
 WITH THIS STANDARD WILL BE ACHIEVED.
  
 2) FUTURE OPERATORS WILL REQUIRE A SEPARATE PERMIT AND
 WILL NEED TO SHOW COMPLIANCE WITH 2017 FBC-B SECTION
 3110.4 VEHICULAR GATE OPENERS. VEHICULAR GATE OPENERS,
 WHERE PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL
 325.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-10-01 Cont ID  
Sent By J.Walker Date 2019-10-01 Time   Rev Time 0.00
Received By jwalker Date 2019-10-01 Time   Sent To  
Notes
2019-10-01 11:41:05SUBMITTED PLANS DO NOT INDICATE THE INSTALLATION OF A
 KNOX KEY SWITCH OR THE SEQUENCE OF GATE OPERATION.
 ALL REQUIREMENTS OF NFPA 1 CH.18 WILL BE ENFORCED AT
 TIME OF INSPECTION

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-09-09 Cont ID  
Sent By J.Walker Date 2019-09-09 Time   Rev Time 0.00
Received By jwalker Date 2019-09-09 Time   Sent To  
Notes
2019-09-09 07:57:11PROVIDE SEQUENCE OF OPPERATION DETAILS
 PROVIDE DETAILS AND LOCATION OF FIRE DEPARTMENT KEY
 ACCESS PANEL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-10-16 Cont ID  
Sent By cpuell Date 2019-10-16 Time 14:52 Rev Time 0.00
Received By cpuell Date 2019-09-26 Time 13:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-09-12 Cont ID  
Sent By lmarchan Date 2019-09-12 Time 14:31 Rev Time 0.00
Received By lmarchan Date 2019-08-01 Time 10:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2019-10-15 Cont ID  
Sent By jwitmer Date 2019-10-15 Time 10:46 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2019-09-13 Cont ID  
Sent By shill Date 2019-09-13 Time 05:02 Rev Time 0.00
Received By shill Date 2019-09-13 Time 05:02 Sent To  
Notes
2019-09-13 05:03:52ORIGINAL SURVEYS ON FILE WITH GUARDHOUSE PERMIT
 PROVISO: RESUBMITTAL NEEDS TO BE REVIEWED FOR SIGNATURE
 REQUIREMENTS
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-10-16 Cont ID  
Sent By jroach Date 2019-10-16 Time 14:04 Rev Time 0.00
Received By jroach Date 2019-10-16 Time 14:04 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-09-12 Cont ID  
Sent By jroach Date 2019-09-12 Time 14:17 Rev Time 0.00
Received By jroach Date 2019-09-12 Time 14:17 Sent To  
Notes
2019-09-12 14:17:33ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 09.12.2019
 PERMIT NO.: 19071543
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. DETAILS/ELEVATIONS SHALL BE PROVIDED OF THE PROPOSED
 GATES.
  
 2. PLEASE EXPLAIN THE PURPOSE OF THE CALL BOX AS IT IS
 STAFF?S UNDERSTANDING THAT THIS WAS A FACILITY OCCUPIED
 BY A SECURITY GUARD 24/7.
  
 3. A DOCUMENT FROM FPL REGARDING AN EASEMENT WAS
 INCLUDED IN THE PERMIT DOCUMENTS, BUT EXHIBIT A WAS
 MISSING AND IT IS UNCLEAR WHY THE DOCUMENT WAS BEING
 PROVIDED. PLEASE CLARIFY.
  
 4. THE SURVEY PROVIDED DOES NOT SHOW THE LOCATION OF
 THE SIDEWALK THAT IS TO BE PROVIDED ADJACENT TO THE
 LAKE MAINTENANCE EASEMENT. PLEASE NOTE THAT THE RFID
 SCANNER AND OPERATOR SHALL NOT ENCROACH INTO OR
 OTHERWISE IMPEDE WITH THE PEDESTRIAN SIDEWALK.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved