| Plan Review Stops For Permit 19071321 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-10-08 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-10-08 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-10-08 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2019-10-08 15:59:05 | PROVISO: | | | ONCE CONTRACTOR DETERMINED, THE VALUE SHOULD BE | | | ADJUSTED PER THE CONTRACT VALUE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-24 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-24 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2019-09-24 13:13:51 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1) 109.3 FBC[AMENDED] PROJECT VALUE APPEARS LOW. (NO | | | PROPOSAL PROVIDED FOR REVIEW) | | | PLEASE PROVIDE COPY OF PROPOSAL WITH CONTRACTOR TO SHOW | | | WORK VALUE EQUAL TO THE AMOUNT SHOWN ON PERMIT | | | APPLICATION, OR PROVIDE ESTIMATE TO SHOW ANTICIPATED | | | COSTS. | | | | | | 2) CORRECTED | | | | | | 3) CORRECTED | | | | | | NEW COMMENT | | | | | | RESPONSE TO PLUMBING COMMENT # 4 INDICATES PERMIT TYPE | | | WILL CHANGE TO OWNER/BUILDER. PLEASE CLARIFY. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-08-07 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-07 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-07 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2019-08-07 15:00:15 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19071321 | | | REVIEWED: AUGUST 7, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[RE] = FBC ENERGY CONSERVATION | | | | | | 1) 109.3 FBC[AMENDED] PROJECT VALUE APPEARS LOW. | | | PLEASE PROVIDE COPY OF PROPOSAL WITH CONTRACTOR TO SHOW | | | WORK VALUE EQUAL TO THE AMOUNT SHOWN ON PERMIT | | | APPLICATION, OR PROVIDE ESTIMATE TO SHOW ANTICIPATED | | | COSTS. | | | | | | 2) 401.2 FBC[RE] PROVIDE ENERGY CALCULATIONS TO MEET | | | REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE. CHOOSE | | | METHOD IN R401.2 AND SUPPLY DOCUMENTATION. | | | -PLEASE SUPPLY ENERGY CALCULATIONS WITH CHECKLISTS AND | | | EPL CARD. | | | 2A) HOW IS CEILING INSULATED? PLEASE INCLUDE IN THE | | | ENERGY CALCULATIONS. | | | | | | 3) WIND DESIGN CRITERIA. | | | RISK CATEGORY = ___(II) | | | EXPOSURE CATEGORY = ___(B,C OR D) | | | BUILDING CLASSIFICATION = __________(ENCLOSED) | | | MEAN BLDG. HGT. = ___FT. ___IN.(TOP OF ROOF DECK) | | | WIND SPEED V ULT = _____(170) | | | WIND SPEED V ASD = _____(132) | | | DESIGN PRESSURE FOR EACH OPENING = +___ & -___ | | | ZONE OF OPENING = (4 OR 5?) | | | | | | WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-10-07 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-10-07 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-10-07 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-09-18 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-09-18 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-09-18 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2019-09-18 12:53:18 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. OK | | | 2. PROVIDE RISER DIAGRAM OF EXISTING SERVICE FOR MAIN | | | HOUSE. PROVIDE DETAILS OF FEED TO PANEL A. NEC 215.5; | | | WPB FBC 107.2.1 | | | 3. OK | | | 4. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 5. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | CORRECTION. NEC 210.12; FBC RE E3902.16 | | | 6. 240.24-E PANEL IN BATHROOM | | | 7. PROVIDE ACCURATE LOAD CALCULATION FOR MAIN SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | | E3602.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-08-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-08-13 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-08-13 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2019-08-13 10:28:35 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. IT APPEARS THAT A SERVICE IS INTENDED FOR THIS | | | STRUCTURE. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS | | | PERMITTED. PROVIDE CORRECTION AND/OR CLARIFICATION. WPB | | | FBC 107.2.1; NEC 230.2; FBC RE E3601.2 | | | 2. PROVIDE RISER DIAGRAM OF EXISTING SERVICE FOR MAIN | | | HOUSE. PROVIDE DETAILS OF FEED TO PANEL A. NEC 215.5; | | | WPB FBC 107.2.1 | | | 3. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 4. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 5. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | CORRECTION. NEC 210.12; FBC RE E3902.16 | | | 6. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | 7. PROVIDE ACCURATE LOAD CALCULATION FOR MAIN SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | | E3602.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-10-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-10-09 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-10-03 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-09-27 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-09-11 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-08-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-08-19 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-07-25 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2019-10-08 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-10-08 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-10-08 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2019-10-08 16:00:42 | OK-PLANS STAMPED | | | MU -2019-027170-0000 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-24 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-24 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2019-09-24 13:31:27 | PLANS ARE STAMPED WITH IMPACT FEE STAMP | | | #MU-2019-027170-0000. PROVIDE RECIEPT FROM PALM BEACH | | | COUNTY IN THE AMOUNT OF $180.65. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-08-07 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-07 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-07 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2019-08-07 15:01:41 | 109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU | | | MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-09-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-09-16 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-09-16 |
Time |
11:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-08-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-08-19 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-08-19 |
Time |
14:04 |
Sent To |
I |
|
| Notes |
| 2019-08-19 14:33:13 | PLAN DENIED | | | 1) REFER TO SECTION R403.7 HEATING AND COOLING | | | EQUIPMENT SIZING. | | | ENERGY CALCULATIONS REQUIRED 2017 FLORIDA ENERGY CODE | | | 2) PROVIDE EQUIPMENT SCHEDULE ON THE PLAN. SECTION 107 | | | FBC 2017 | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-09-24 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-09-24 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2019-09-24 11:03:02 | PLUMBING COMMENTS: APPROVED W/PROVISO | | | SEE RED LINED COMMENTS AND DRAWING CONFIGURATIONS ON | | | PLAN SHEET P101 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-08-15 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-08-15 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2019-08-15 15:24:03 | 08/14/2019 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. THE CLEAN OUT AT THE END OF THE SYSTEM NEEDS TO BE | | | IN THE OTHER SIDE OF BUILDING AS A CLEAN-OUT REQUIRED | | | AT THE BUILDING JUNCTION PER 2017 FBC RES. SEC. | | | 3005.2.3 BUILDING DRAIN AND BUILDING SEWER JUNCTION. | | | | | | THE JUNCTION OF THE BUILDING DRAIN AND THE BUILDING | | | SEWER SHALL BE SERVED BY A CLEANOUT THAT IS LOCATED AT | | | THE JUNCTION OR WITHIN 10 FEET (3048 MM) DEVELOPED | | | LENGTH OF PIPING UPSTREAM OF THE JUNCTION. FOR THE | | | REQUIREMENTS OF THIS SECTION, REMOVAL OF A WATER CLOSET | | | SHALL NOT BE REQUIRED TO PROVIDE CLEANOUT ACCESS. | | | | | | 2. IF THE SHOWER PAN IS NOT RECEDED AND NOT IN A | | | CONTINUOUS POOR IT SHALL COMPLY WITH REQUIRE LINING PER | | | 2017 FBC RES. SEC. 2709.2. | | | | | | 3. CITY OF WEST PALM BEACH ORD 2853-95 REQUIRES A | | | BACKFLOW FOR A MULTI-DWELLING, BY A LICENSED CONTRACTOR | | | WITH PERMIT APPLICATION INSPECTION AND CERTIFICATION | | | FROM UTILITIES DEPARTMENT. | | | | | | 4. THERE IS A VALUE LISTED ON THE APPLICATION AND THE | | | OVERALL VALUE IS LOW. WPB AMENDMENTS TO THE FBC 109.3 | | | BUILDING PERMITS VALUATIONS. IF IN THE OPINION OF THE | | | BUILDING OFFICIAL, THE CLAIMED VALUATION OF BUILDING, | | | ALTERATION, STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR | | | PLUMBING SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED UNLESS THE | | | APPLICANT CAN SHOW DETAILED, QUANTITY ESTIMATES, AND/OR | | | BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO | | | MEET THE APPROVAL OF THE BUILDING OFFICIAL. FOR | | | PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS | | | SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-10-09 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-10-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-10-09 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-09 09:21:30 | NO KITCHEN FACILITIES PERMITTED, AS AN ACCESSORY | | | DWELLING UNIT IS PROHIBITED IN THE SF7 ZONING DISTRICT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-09-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-09-26 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-09-27 08:25:25 | NO KITCHEN FACILITIES PERMITTED, AS AN ACCESSORY | | | DWELLING UNIT IS PROHIBITED IN THE SF7 ZONING DISTRICT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-08-09 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2019-08-09 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-09 09:59:26 | ** FAILED ** | | | | | | 1.) AN ACCESSORY DWELLING UNIT IS NOT PERMITTED IN THE | | | SF7 ZONING DISTRICT. | | | | | | | | | NOTES: | | | | | | * REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|