Plan Review Details - Permit 19071048
Plan Review Stops For Permit 19071048
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-08-23 Cont ID  
Sent By fgiaquin Date 2019-08-22 Time 22:10 Rev Time 0.00
Received By fgiaquin Date 2019-08-22 Time 21:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-07-28 Cont ID  
Sent By fgiaquin Date 2019-07-28 Time 04:58 Rev Time 0.00
Received By fgiaquin Date 2019-07-28 Time 03:45 Sent To  
Notes
2019-07-28 04:57:25CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. SPEC SHEETS FOR MAGNETIC DOOR LOCK AND HORN STROBE
 DEVICES DO NOT SHOW THAT THEY ARE LISTED BY A NRTL
 (NATIONALL RECOGNIZED TESTING LABORATORY) FOR EXAMPLE
 UL, ETL, CSA, ETC. NEC 90.7,110.2,110.3B FBC107.2.1
  
 2. FIRE ALARM DESIGNS OVER $5000 MUST BE SIGNED AND
 SEALED BY A DESIGN PROFESSIONAL FBC 105.3.1.2 #4 FS
 471.003(2)(H); 471.025; WPB FBC 107.1
  
 3. VALUE LOW FOR AMOUNT OF WORK SHOWN.
  
 FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
  
  
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop E ELECTRICAL
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By fgiaquin Date 2019-07-28 Time 03:45 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-08-21 Cont ID  
Sent By pleduc Date 2019-08-21 Time   Rev Time 0.00
Received By pleduc Date 2019-08-21 Time 09:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-07-22 Cont ID  
Sent By pleduc Date 2019-07-22 Time   Rev Time 0.00
Received By pleduc Date 2019-07-22 Time 09:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-23 Cont ID  
Sent By fgiaquin Date 2019-08-23 Time 05:53 Rev Time 0.00
Received By fgiaquin Date 2019-08-20 Time 13:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-08-16 Cont ID  
Sent By pvalenti Date 2019-08-16 Time 07:26 Rev Time 0.00
Received By pvalenti Date 2019-07-19 Time 16:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2019-08-14 Cont ID  
Sent By pvalenti Date 2019-08-14 Time 07:32 Rev Time 0.00
Received By ccole Date 2019-08-14 Time 07:31 Sent To  
Notes
2019-08-14 07:33:23MECHANICAL PLAN REVIEW
  
 NOT REQUIRED PER CHRIS COLE (REMOTELY)

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-08-23 Cont ID  
Sent By fgiaquin Date 2019-08-22 Time 21:10 Rev Time 0.00
Received By fgiaquin Date 2019-08-22 Time 21:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-07-28 Cont ID  
Sent By fgiaquin Date 2019-07-28 Time 04:58 Rev Time 0.00
Received By fgiaquin Date 2019-07-28 Time 04:57 Sent To  
Notes
2019-07-28 04:57:59FIRE ALARM DESIGNS OVER $5000 MUST BE SIGNED AND SEALED
 BY A DESIGN PROFESSIONAL FBC 105.3.1.2 #4 FS
 471.003(2)(H); 471.025; WPB FBC 107.1