Plan Review Details - Permit 19070770
| Plan Review Stops For Permit 19070770 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-08-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-21 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-21 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-14 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-14 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2019-08-14 15:14:38 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | 2ND PLAN REVIEW DENIED: | | | | | | FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | PLEASE NOTE THAT TEST REPORTS ARE REQUIRED - | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-19 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-19 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2019-07-19 14:37:11 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FBC B 1207.2 & .3, STC AND IIC TESTS PROVIDED ARE | | | FOR HARDWOOD, LAMINATE PROPOSED. AN ANALYSIS BY THE | | | MANUFACTURER, OR TEST REPORTS FOR LAMINATE, IS | | | REQUIRED. | | | | | | 2. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-08-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-21 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-20 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2019-08-20 15:39:15 | RESUB ROUTED TO PVALENTI |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-14 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-06 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2019-08-07 14:09:49 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-19 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-16 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2019-07-17 11:29:33 | BLDG <5K |
|
|
|