Plan Review Details - Permit 19070762
Plan Review Stops For Permit 19070762
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-24 Cont ID  
Sent By cthroop Date 2019-09-24 Time 09:23 Rev Time 0.00
Received By cthroop Date 2019-09-24 Time 09:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-08-09 Cont ID  
Sent By cthroop Date 2019-08-09 Time 16:38 Rev Time 0.00
Received By cthroop Date 2019-08-09 Time 14:29 Sent To  
Notes
2019-08-09 16:44:23BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGNER SHALL SIGN PLAN PER FBC 107.2.1.
  
 2. PROVIDE SHOWER PAN DETAIL PER P2709.1
  
 3. PROVIDE DEMENSIONS OF SHOWER COMPARTMENT PER P2708.1
  
 4. STATE CFM OF EXHAUST FAN PER R303.3 & M1507.
  
 5. STATE CEILING HEIGHT OF BATHROOM. CEILING HEIGHT
 SHALL COMPLY WITH R305.1
  
 6. PROVIDE DEMENSIONS OF BATHROOM FIXTURES. CLEAR SPACE
 SHALL COMPLY WITH R307.1
  
 7. STATE CLASSIFICATION OF SHOWER DOOR GLAZING PER
 TABLE R308.1 (1)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-09-18 Cont ID  
Sent By ppetty Date 2019-09-18 Time 10:10 Rev Time 0.00
Received By ppetty Date 2019-09-18 Time 10:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-08-02 Cont ID  
Sent By fgiaquin Date 2019-08-02 Time 13:04 Rev Time 0.00
Received By fgiaquin Date 2019-08-02 Time 11:00 Sent To  
Notes
2019-08-02 11:23:13ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS BOTH NEW AND EXISTING (FOR ADDITION OF WATER
 HEATER) NEC 220; FBC RE E3602.2
  
 2. PROVIDE ACTUAL LOCATION OF WATER HEATER, SHOWING
 SIZE OF WATER HEATER, WIRE SIZE, OCP SIZE ETC. FBC
 107.2.1
  
 3. ELECTRICAL PLAN IS REQUIRED TO BE SIGNED BY PERSON
 RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. FS
 481.229; WPB FBC 107.2.1, 107.3.5.1.2
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-09-24 Cont ID  
Sent By cthroop Date 2019-09-24 Time 09:24 Rev Time 0.00
Received By cthroop Date 2019-09-06 Time 09:44 Sent To  
Notes
2019-09-09 09:44:30R32

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-08-09 Cont ID  
Sent By cthroop Date 2019-08-09 Time 16:44 Rev Time 0.00
Received By cthroop Date 2019-07-16 Time 15:16 Sent To  
Notes
2019-07-17 15:16:20R01

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-09-24 Cont ID  
Sent By cthroop Date 2019-09-24 Time 09:24 Rev Time 0.00
Received By cthroop Date 2019-09-24 Time 09:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-08-09 Cont ID  
Sent By cmontell Date 2019-08-09 Time 13:25 Rev Time 0.00
Received By cmontell Date 2019-08-09 Time 13:23 Sent To  
Notes
2019-08-09 13:25:46MECHANICAL PLAN REVIEW FAIL
 1 - NEED MECHANICAL PLAN PER WEST PALM BEACH AMENDMENTS
 TO THE FLORIDA BUILDING CODE, 6TH EDITION (2017),
 CHAPTER 1, ADMINISTRATION, SEC 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 CHRIS MONTELLO
 805-6733

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-09-17 Cont ID  
Sent By jesmith Date 2019-09-17 Time 12:04 Rev Time 0.00
Received By jesmith Date 2019-09-17 Time 12:00 Sent To  
Notes
2019-09-17 12:04:34PLUMBING COMMENTS: APPROVED

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-08-01 Cont ID  
Sent By jesmith Date 2019-08-01 Time 08:29 Rev Time 0.00
Received By jesmith Date 2019-08-01 Time 08:08 Sent To  
Notes
2019-08-01 08:29:05CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 96= STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 PLUMBING COMMEMTS: DENIED
  
 1. PER WPB FBC 107.2.1 AND 107.3.5.3(12), PROVIDE CODE
 COMPLIANT PLUMBING (SANITARY) RISER DIAGRAM
  
 2. PER WPB FBC 107.2.1, PROVIDE INTERIOR FINISH
 DIMENSIONS OF BATHROOM SHOWING COMPLIANCE WITH FBC RES
 P2705.1, P2708.1 AND P2708.1.1. SPECIFICALLY, THE
 FOLLOWING SHOULD BE MADE CLEAR.
  
 A.A WATER CLOSET, LAVATORY OR BIDET SHALL NOT BE SET
 CLOSER THAN 15 INCHES (381 MM) FROM ITS CENTER TO ANY
 SIDE WALL, PARTITION OR VANITY OR CLOSER THAN 30 INCHES
 (762 MM) CENTER-TO-CENTER BETWEEN ADJACENT FIXTURES.
 THERE SHALL BE A CLEARANCE OF NOT LESS THAN 21 INCHES
 (533 MM) IN FRONT OF A WATER CLOSET, LAVATORY OR BIDET
 TO ANY WALL, FIXTURE OR DOOR.
 B.SHOWER COMPARTMENTS SHALL HAVE NOT LESS THAN 900
 SQUARE INCHES (0.6 M2) OF INTERIOR CROSS-SECTIONAL
 AREA. SHOWER COMPARTMENTS SHALL BE NOT LESS THAN 30
 INCHES (762 MM) IN MINIMUM DIMENSION MEASURED FROM THE
 FINISHED INTERIOR DIMENSION OF THE SHOWER COMPARTMENT,
 EXCLUSIVE OF FIXTURE VALVES, SHOWER HEADS, SOAP DISHES,
 AND SAFETY GRAB BARS OR RAILS.
 C.THE SHOWER COMPARTMENT ACCESS AND EGRESS OPENING
 SHALL HAVE A CLEAR AND UNOBSTRUCTED FINISHED WIDTH OF
 NOT LESS THAN 22 INCHES (559 MM).
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19070762 349 NOTTINGHAM BLVD