Plan Review Details - Permit 19070727
Plan Review Stops For Permit 19070727
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-08-02 Cont ID  
Sent By rmcdouga Date 2019-08-02 Time 17:44 Rev Time 0.00
Received By rmcdouga Date 2019-08-02 Time 16:35 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-07-18 Cont ID  
Sent By rmcdouga Date 2019-07-18 Time 08:44 Rev Time 0.00
Received By rmcdouga Date 2019-07-18 Time 07:51 Sent To I
Notes
2019-07-18 08:44:19PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 SUBMITTALS DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE EXTERIOR FRAMING AND SHEATHING DOCUMENTS ARE
 REQUIRED TO BE SIGNED AND SEALED BY THE DELEGATE
 ENGINEER. WHEN PAPER DOCUMENTS ARE SUBMITTED FOR PUBLIC
 RECORD THEY ARE REQUIRED TO COMPLY WITH FAC
 61G15-23.003 PROCEDURES FOR PHYSICALLY SIGNING AND
 SEALING PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS.
 ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN
 ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025,
 F.S., AND RULE 61G15-23.001, F.A.C. MUST BE PHYSICALLY
 SIGNED, DATED AND SEALED AS PROVIDED HEREIN BY THE
 PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE.
 (1) THE LICENSEE SHALL SIGN BY HAND AN ORIGINAL OF THE
 LICENSEE'S SIGNATURE ON EACH PAGE REQUIRED TO BE
 SEALED. A SCANNED, FACSIMILE, DIGITALLY CREATED OR
 COPIED IMAGE OF THE LICENSEE'S SIGNATURE SHALL NOT BE
 USED.
 (2) THE LICENSEE MUST THEN USE A WET SEAL, A DIGITALLY
 CREATED SEAL, OR AN EMBOSSING SEAL PLACED PARTIALLY
 OVERLAPPING THE LICENSEE?S SIGNATURE ON EACH PAGE
 REQUIRED TO BE SEALED. THE PLACEMENT OF THE SEAL SHALL
 NOT RENDER THE SIGNATURE ILLEGIBLE.
  
 2) THIS PROJECT IS PERMITTED UNDER THE 2014 FBC FIFTH
 EDITION. THE SUBMITTAL DOCUMENTS SPECIFY THE 2017 FBC
 SIXTH EDITION. BOTH OF THESE EDITIONS REFERENCE ASCE
 7-10. PLEASE CORRECT SUBMITTALS.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-02 Cont ID  
Sent By rmcdouga Date 2019-08-02 Time 17:44 Rev Time 0.00
Received By rmcdouga Date 2019-08-01 Time 14:03 Sent To  
Notes
2019-08-02 14:03:39RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-07-18 Cont ID  
Sent By rmcdouga Date 2019-07-18 Time 08:44 Rev Time 0.00
Received By rmcdouga Date 2019-07-16 Time 15:51 Sent To  
Notes
2019-07-17 15:51:10SUBMITTAL ROUTED TO RMCDOUGAL


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved