Plan Review Details - Permit 19070700
Plan Review Stops For Permit 19070700
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-08-29 Cont ID  
Sent By rmcdouga Date 2019-08-29 Time 09:46 Rev Time 0.00
Received By rmcdouga Date 2019-08-29 Time 09:46 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-07-23 Cont ID  
Sent By jwitmer Date 2019-07-23 Time 13:54 Rev Time 0.00
Received By jwitmer Date 2019-07-23 Time 13:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-08-21 Cont ID  
Sent By jpearson Date 2019-08-21 Time 13:30 Rev Time 0.00
Received By jpearson Date 2019-08-21 Time 13:30 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-07-24 Cont ID  
Sent By jpearson Date 2019-07-24 Time 11:16 Rev Time 0.00
Received By jpearson Date 2019-07-24 Time 11:16 Sent To  
Notes
2019-07-24 11:15:50CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND
 SEALED BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY
 THE ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H);
 471.025; WPB FBC 107.2.1, 107.3.5
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-07-17 Cont ID  
Sent By pleduc Date 2019-07-17 Time   Rev Time 0.00
Received By pleduc Date 2019-07-17 Time 15:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-08-29 Cont ID  
Sent By rmcdouga Date 2019-08-29 Time 09:46 Rev Time 0.00
Received By rmcdouga Date 2019-08-27 Time 16:05 Sent To  
Notes
2019-08-27 16:05:20RESUB ROUTED TO JESMITH

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-27 Cont ID  
Sent By jesmith Date 2019-08-27 Time 14:14 Rev Time 0.00
Received By jesmith Date 2019-08-27 Time 14:14 Sent To  
Notes
2019-08-19 16:09:08RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-07-26 Cont ID  
Sent By gjohnson Date 2019-07-26 Time 10:43 Rev Time 0.00
Received By gjohnson Date 2019-07-15 Time 14:10 Sent To  
Notes
2019-07-16 14:10:31B16

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-08-29 Cont ID  
Sent By jesmith Date 2019-08-29 Time 08:40 Rev Time 0.00
Received By jesmith Date 2019-08-29 Time 08:37 Sent To  
Notes
2019-08-29 08:40:40PLUMBING COMMEMTS: APPROVED
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-08-27 Cont ID  
Sent By jesmith Date 2019-08-27 Time 14:13 Rev Time 0.00
Received By jesmith Date 2019-08-27 Time 14:12 Sent To  
Notes
2019-08-27 14:13:42CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 2ND REVIEW
  
 PLUMBING COMMEMTS: DENIED
  
 1. SHOW DIMENSIONS AND LABEL CLEAR FLOOR SPACE FOR THE
 TOILET. PER FBC ACC 604.3.1
  
 2. TOILET PAPER DISPENSERS SHALL BE 7 INCHES MINIMUM
 AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET
 MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET
 OF THE DISPENSER SHALL BE 15 INCHES MINIMUM AND 48
 INCHES MAXIMUM ABOVE THE FINISH FLOOR. PER FBC ACC
 604.7
  
 3. SHOW COMPLIANCE FOR LAVATORY IN THE ACCESSIBLE STALL
 HEIGHT OF THE RIM AND KNEE AND TOE CLEARANCE. FBC ACC
 606.2, 606.3
  
 4. GRAB BARS SHALL BE MEASURED FROM FINISH FLOOR TO THE
 TOP OF THE GRIPPING SURFACE AT 33" MIN- 36" MAX. PER
 FBC ACC 609.4
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19070700 1601 BELVEDERE RD

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-07-26 Cont ID  
Sent By gjohnson Date 2019-07-26 Time 10:42 Rev Time 0.00
Received By gjohnson Date 2019-07-26 Time 09:45 Sent To  
Notes
2019-07-26 10:42:581ST REVIEW: 19070700
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. SHOW DIMENSIONS AND LABEL CLEAR FLOOR SPACE FOR THE
 TOILET. PER FBC ACC 604.3.1
  
 2. TOILET PAPER DISPENSERS SHALL BE 7 INCHES MINIMUM
 AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET
 MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET
 OF THE DISPENSER SHALL BE 15 INCHES MINIMUM AND 48
 INCHES MAXIMUM ABOVE THE FINISH FLOOR. PER FBC ACC
 604.7
  
 3. SHOW COMPLIANCE FOR LAVATORY IN THE ACCESSIBLE STALL
 HEIGHT OF THE RIM AND KNEE AND TOE CLEARANCE. FBC ACC
 606.2, 606.3
  
 4. GRAB BARS SHALL BE MEASURED FROM FINISH FLOOR TO THE
 TOP OF THE GRIPPING SURFACE AT 33" MIN- 36" MAX. PER
 FBC ACC 609.4
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved