Plan Review Details - Permit 19070649
| Plan Review Stops For Permit 19070649 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2019-07-30 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2019-07-30 |
Time |
14:37 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-07-18 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2019-07-18 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2019-07-18 |
Time |
16:22 |
Sent To |
I |
|
| Notes |
| 2019-07-18 16:21:40 | 7/18/19 1ST REVIEW DENIED A. BELISLE | | | | | | 1) THE CLAIMED VALUE APPEARS TO BE UNDERESTIMATED ON | | | THE APPLICATION, PLEASE PROVIDE A BONA FIDE SIGNED | | | CONTRACT. WPB AMENDMENTS TO THE FBC SEC. 109.3 BUILDING | | | PERMIT VALUATIONS. | | | | | | 2) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED GAS | | | APPLIANCES. WHERE IS COMBUSTION AIR PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR? 2017 FGC | | | SEC.304.9.3 OR 2017 FBC R G2407.9.3. COMBINED | | | COMBUSTION AIR AND VENTILATION AIR SYSTEM. | | | | | | 3) I HAVE RESEARCHED CITY RECORDS BACK TO 0000 AND | | | THERE IS NO RECORD OF A PERMIT FOR THE INSTALLATION OF | | | ANY GAS. WHAT OTHER APPLIANCES/EQUIPMENT IS SUPPLIED BY | | | THIS "EXISTING GAS"? SINCE THERE IS NO RECORD OF A | | | PERMIT FOR THE GAS, THE GAS MUST BE INCLUDED IN THIS | | | PERMIT FOR THIS SCOPE OF WORK. WPB AMENDMENTS TO THE | | | FBC SEC. 105.1. | | | | | | 4) PLEASE CLARIFY THE NEW 1/2" WATER LINE GOING TO THE | | | WASHING MACHINE, IS THIS THE OLD LOCATION OF THE WATER | | | HEATER? | | | | | | 5) HOW MANY GALLONS IS THE REPLACEMENT WATER HEATER ? | | | | | | 6) NO VALUE OR WORK DESCRIPTION WAS LISTED FOR PERMIT | | | #19070651. PLEASE STATE THE WORK DECRIPTION AND VALUE | | | ON THE APPLICATION | | | | | | ATELYO BELISLE | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6695 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-07-19 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-07-12 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2019-07-15 11:30:28 | PLUMB <5K |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2019-07-30 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2019-07-30 |
Time |
14:36 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-18 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2019-07-18 |
Time |
06:37 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2019-07-18 |
Time |
06:40 |
Sent To |
I |
|
| Notes |
| 2019-07-18 06:36:24 | 7/18/19 1ST REVIEW DENIED A. BELISLE | | | | | | 1) THE CLAIMED VALUE APPEARS TO BE UNDERESTIMATED ON | | | THE APPLICATION, PLEASE PROVIDE A BONA FIDE SIGNED | | | CONTRACT. WPB AMENDMENTS TO THE FBC SEC. 109.3 BUILDING | | | PERMIT VALUATIONS. | | | | | | 2) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED GAS | | | APPLIANCES. WHERE IS COMBUSTION AIR PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR? 2017 FGC | | | SEC.304.9.3 OR 2017 FBC R G2407.9.3. COMBINED | | | COMBUSTION AIR AND VENTILATION AIR SYSTEM. | | | | | | 3) I HAVE RESEARCHED CITY RECORDS BACK TO 0000 AND | | | THERE IS NO RECORD OF A PERMIT FOR THE INSTALLATION OF | | | ANY GAS. WHAT OTHER APPLIANCES/EQUIPMENT IS SUPPLIED BY | | | THIS "EXISTING GAS"? SINCE THERE IS NO RECORD OF A | | | PERMIT FOR THE GAS, THE GAS MUST BE INCLUDED IN THIS | | | PERMIT FOR THIS SCOPE OF WORK. WPB AMENDMENTS TO THE | | | FBC SEC. 105.1. | | | | | | 4) PLEASE CLARIFY THE NEW 1/2" WATER LINE GOING TO THE | | | WASHING MACHINE, IS THIS THE OLD LOCATION OF THE WATER | | | HEATER? | | | | | | 5) HOW MANY GALLONS IS THE REPLACEMENT WATER HEATER ? | | | | | | 6) NO VALUE OR WORK DESCRIPTION WAS LISTED FOR PERMIT | | | #19070651. PLEASE STATE THE WORK DECRIPTION AND VALUE | | | ON THE APPLICATION | | | | | | ATELYO BELISLE | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6695 | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |