Plan Review Details - Permit 19070609
| Plan Review Stops For Permit 19070609 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-10-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-16 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-16 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2019-10-16 12:45:05 | PROVISO: REMOVE CABANA, PERGOLA/DECK & SPIRAL STAIRCASE | | | FROM SUBMITTAL. THESE ITEMS WILL BE SUBMITTED AS A | | | REVISION. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-10-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-15 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-10 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2019-10-15 11:46:11 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW EXTERIOR DOORS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 2. SPIRAL STAIRCASE SHOP DRAWINGS SHALL BE REVIEWED AND | | | APPROVED BY A LICENSED FLORIDA DESIGN PROFESSIONAL. | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | 3. PROVIDE A ROOF FRAMING PLAN FOR THE CABANA. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | | COMPONENTS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-31 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-31 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2019-07-31 12:56:37 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 1. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE | | | OF WORK. | | | | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 2. INCORRECT CODE REFERENCE STATED IN NOTE #2 PLAN PAGE | | | E-1. | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION. | | | | | | 3. SCOPE OF WORK INCLUDES DEMO OF EXISTING CABANA. THIS | | | WORK SHALL BE BY SEPERATE PERMIT. | | | PLEASE SEE THE "DEMOLITION PERMIT APPLICATION | | | CHECKLIST" WHICH YOU CAN FIND AT THE FOLLOWING WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | 4. PROVIDE SITE PLAN. | | | | | | 5. PROVIDE TWO COPIES OF A RECENT SURVEY. | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED ON A BOUNDARY LINE SURVEY. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-10-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-10-02 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-10-01 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2019-10-02 08:25:26 | PASSED WITH PROVISOS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-30 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-30 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2019-07-30 15:53:07 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 | | | 2. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE | | | SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC | | | 410.10(D); FBC RE E4003.11 | | | 3. NOTE 27 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | CORRECTION. NEC 210.12; FBC RE E3902.16 | | | 5. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 6. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE, INCLUDING GARAGE DOOR OPENER. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2 | | | 7. RECEPTACLES INSTALLED TO SERVE THE COUNTER TOP IN | | | KITCHEN, INCLUDING THE ISLAND, REQUIRE GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.6 | | | 8. DETAIL FOR DISHWASHER / DISPOSAL DOES NOT PERMIT FOR | | | GFCI PROTECTION OF DISHWASHER. PROVIDE GFCI PROTECTION | | | FOR DISHWASHER. NEC 210.8(D); FBC RE E3902.10 | | | 9. RECEPTACLE OUTLETS IN BATHROOMS REQUIRE GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8; FBC RE | | | E3902.1 | | | 10. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | 11. PLAN DOES NOT SHOW LOCATION OF PANEL B. PROVIDE | | | CORRECTION. WPB FBC 107.2.1 | | | 12. PLAN DOES NOT SHOW LOCATION OF LAUNDRY CIRCUITS | | | SHOWN IN PANEL SCHEDULEL. PROVIDE CORRECTION. WPB FBC | | | 107.2.1 | | | 13. PLAN SHOWS WHAT APPEARS TO BE STANDARD RECESS | | | LIGHTS IN CLOSET. PER CODE, LIGHTING WITH OPEN OR | | | PARTIALLY ENCLOSED LAMPS AND PENDANT LUMINAIRES OR | | | LAMPHOLDERS SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. | | | PROVIDE CORRECTION. NEC 410.16; FBC RE E4003.12 | | | 14. PLAN DOES NOT SHOW LOCATION OF AC EQUIPMENT. | | | PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR SERVICING | | | OF A/C EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER | | | CODE. NEC 210.63; FBC RE E3901.12 | | | 15. RECEPTACLES INSTALLED OUTDOORS REQUIRE GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8; FBC RE | | | E3902.3 | | | 16. RISER DIAGRAM DOES NOT PROVIDE WIRE SIZE TO MDP | | | FROM METER. PROVIDE CORRECTION. WPB FBC 107.2.1 | | | 17. RISER DIAGRAM SHOWS 4 CONDUCTORS AND AN EQUIPMENT | | | GROUND TO SUB-PANELS. IS THIS A 3 PHASE SYSTEM? LOAD | | | CALCULATION AND PANEL SCHEDULES SHOW A SINGLE PHASE | | | SERVICE. CORRECT DISCREPANCY. WPB FBC 107.2.1; NEC | | | 215.5 | | | 18. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM | | | BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET | | | FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE | | | R314.3(4), NFPA 72:29.8.3.4 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-10-09 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-10-09 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-09-25 |
Time |
16:08 |
Sent To |
M |
|
| Notes |
| 2019-09-25 16:08:36 | 10/09/19 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-07-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-31 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-31 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2019-07-31 13:29:55 | GAS PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | 1. GAS SHALL BE BY SEPERATE PERMIT. | | | | | | PROVIDE THE FOLLOWING INFORMATION FOR YOUR GAS PERMIT | | | AND REVIEW. | | | | | | 1. SUBMIT TWO COPIES OF AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS THE LENGTH OF ALL CUT SECTIONS OF PIPE | | | PER 2017 FBC-R SEC. G2413.4.1, G2413.4.2. | | | | | | 2. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING | | | | | | (IF APPLICABLE) FOR EACH PIPE SIZE. WPB AMENDMENTS TO | | | FBC SEC.107.2.1. | | | | | | 3. TYPE OF GAS (LP OR NATURAL).WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | 4. LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-RES. SEC. | | | G2413.3, G2413.4 AND TABLES G2413.4 (1 ) THROUGH | | | G2413.4 (21). CONTRACTOR TO STATE WHICH TABLES ARE | | | USED. | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2017 | | | FBC-RES. SEC. G 2413.4.1, G2413.4.2. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-RES. SEC.G 2407.1 AND G2439.4 (CLOTHES DRYERS). | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC RES. SEC. G2413.2, G2413.4.3. | | | | | | 8. SUBMIT TWO COPIES OF A DETAIL SHOWING THE TYPE OF | | | VENT, LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE | | | THE ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) PER | | | 2017 FBC-RES. SEC.G2426 THROUGH G2439. | | | | | | 9. SUBMIT TWO COPIES OF THE MANUFACTURER?S | | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND | | | 301.3 OR 2017 FBC-RES. SEC. G2404.3. GAS APPLIANCES | | | SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS | | | FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT | | | THE TIME OF INSPECTION. FBC-RES. SEC.G2408.1. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-10-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-16 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-16 |
Time |
12:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-10-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-15 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-20 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-31 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-12 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-10-11 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-10-11 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-10-11 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-27 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-07-27 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-07-27 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2019-07-27 07:25:50 | MECHANICAL PLAN REVIEW FAIL | | | | | | NEED MECHANICAL PLAN PER WEST PALM BEACH AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, 6TH EDITION (2017), | | | CHAPTER 1, ADMINISTRATION, SEC 107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | | | | CHRIS MONTELLO | | | 805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-09-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-09-25 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-09-25 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2019-09-25 16:13:27 | 09/25/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-31 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-31 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2019-07-31 13:24:16 | PLUMBING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | 1. PLUMBING SUPPLY ISO SHOWS EXISTING WATER HEATER. | | | | | | 2. PLAN PAGE P-2 SHOWS WATER HEATER DETAIL. | | | | | | IS THE WATER HEATER BEING REPLACED? | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-10-16 |
|
|
Cont ID |
|
| Sent By |
rfalcone |
Date |
2019-10-16 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
rfalcone |
Date |
2019-10-16 |
Time |
13:23 |
Sent To |
I |
|
| Notes |
| 2019-10-16 13:25:22 | ONLY INTERIOR RENOVATIONS. RF | | | | | | PROVISO: REMOVE CABANA, PERGOLA/DECK & SPIRAL STAIRCASE | | | FROM SUBMITTAL. THESE ITEMS WILL BE SUBMITTED AS A | | | REVISION. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-09-27 |
|
|
Cont ID |
|
| Sent By |
rfalcone |
Date |
2019-09-27 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
rfalcone |
Date |
2019-09-27 |
Time |
09:24 |
Sent To |
I |
|
| Notes |
| 2019-09-27 09:26:41 | 09/27/19 FAILED. | | | | | | THE PERGOLA ACCESSORY STRUCTURE ON THE EASTERN PORTION | | | OF THE SUBJECT PROPOERTY IS ENCROACHING THE REQUIRED 5 | | | FT SIDE SETBACK. PLEASE REVISE PLANS TO MEET CODE | | | REQUIREMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: (561) 822-1442 | | | E-MAIL: [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy