Plan Review Details - Permit 19070587
Plan Review Stops For Permit 19070587
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-08-08 Cont ID  
Sent By pvalenti Date 2019-08-08 Time 08:47 Rev Time 0.00
Received By pvalenti Date 2019-08-08 Time 08:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-07-29 Cont ID  
Sent By jwitmer Date 2019-07-29 Time 15:30 Rev Time 0.00
Received By jwitmer Date 2019-07-29 Time 15:16 Sent To  
Notes
2019-07-29 15:30:032017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19070587
 ADD: 701 S. OLIVE AVE. SUITE: 519
 CONT: GMB CONSTRUCTION, INC.
 TEL: 305-613-5572
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JULY 29/ 2019
 ACTION: DENIED
  
 1) SHEET A-1 DOES INDICATE NEW 24 X 48 INCH PORCELLAIN
 FLOOR TILE TO BE INSTALLED WITHIN THE UNITE WITH
 EXCEPTION OF THE 2 BATHROOMS. PLEASE REVIEW THE MISSING
 DOCUMENTS NEEDED FOR CODE COMPLIANCE. BLDG TYPE: TYPE
 I/ TYPE II FLOOR INSULATION (FBC-B 2017)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
  
 1A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2017 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 1C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-08-05 Cont ID  
Sent By jleahy Date 2019-08-05 Time 11:30 Rev Time 0.00
Received By jleahy Date 2019-08-05 Time 11:30 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-07-16 Cont ID  
Sent By pleduc Date 2019-07-16 Time   Rev Time 0.00
Received By pleduc Date 2019-07-16 Time 13:10 Sent To  
Notes
2019-07-16 13:12:51THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) MAINTAIN THE FIRE ALARM AND FIRE SPRINKLER
 PROTECTION.
  
 ENSURE PRECAUTION AROUND KITCHEN SPRINKLER HEADS TO
 AVOID DAMAGE AND ACCIDENTAL ACTIVATION OF WATER
 DISCHARGE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-08-05 Cont ID  
Sent By jleahy Date 2019-08-05 Time 11:30 Rev Time 0.00
Received By jleahy Date 2019-07-12 Time 12:46 Sent To  
Notes
2019-07-15 12:46:22B14

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-08-01 Cont ID  
Sent By jesmith Date 2019-08-01 Time 15:43 Rev Time 0.00
Received By jesmith Date 2019-08-01 Time 15:07 Sent To  
Notes
2019-08-01 15:43:25PLUMBING COMMEMTS: APPROVED