| Plan Review Stops For Permit 19070552 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-11-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-11-26 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-25 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-08-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-14 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-13 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2019-08-14 08:08:53 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DESIGNER OF RECORD TO SIGN AND SEAL PLANS. | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND | | | EXTERIOR DOORS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | YOU MAY CHOOSE TO DEFER THESE PRODUCT APPROVALS | | | | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 3. PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2020-01-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-01-06 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-01-06 |
Time |
12:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-12-30 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-12-30 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-12-30 |
Time |
11:01 |
Sent To |
P |
|
| Notes |
| 2019-12-30 11:02:45 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. | | | 2. | | | 3. | | | 4. IF A PANEL IS TO BE INSTALLED IN THE GARAGE, FEEDERS | | | THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THIS PANEL. NEC 225.31, 225.32 250.32 | | | NEED METAL PIPE OR GROUND WIRE TO GARAGE | | | 5. | | | 6. | | | 7. SHOW LOCATION OF MINI-SPLIT UNIT ON ELECTRICAL PLAN. | | | 110.26 DISCONNECT BEHIND UNIT.OUTLET FOR UNIT MISSING | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-11-20 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-11-20 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-11-20 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2019-11-20 13:20:14 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. | | | 2. | | | 3. | | | 4. IF A PANEL IS TO BE INSTALLED IN THE GARAGE, FEEDERS | | | THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THIS PANEL. NEC 225.31, 225.32 250.32 | | | NEED METAL PIPE OR GROUND WIRE TO GARAGE | | | 5. | | | 6. | | | 7. SHOW LOCATION OF MINI-SPLIT UNIT ON ELECTRICAL PLAN. | | | 110.26 DISCONNECT BEHIND UNIT.OUTLET FOR UNIT MISSING | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-08-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-08-07 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-08-07 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2019-08-07 10:31:59 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC | | | 225.30 | | | 2. IF A PANEL IS TO BE INSTALLED IN THE GARAGE, PROVIDE | | | LOCATION OF PANEL TO CONFIRM CODE COMPLIANCE. PROVIDE | | | PANEL SCHEDULE. NEC 210.8, 210.12, 210.19, 210.20, | | | 215.5, 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 3. IF A PANEL IS TO BE INSTALLED IN THE GARAGE, PROVIDE | | | GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A BUILDING | | | OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH CIRCUIT. | | | NEC 250.32; FBC RE3607.3 | | | 4. IF A PANEL IS TO BE INSTALLED IN THE GARAGE, FEEDERS | | | THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THIS PANEL. NEC 225.31, 225.32 | | | 5. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 6. LOAD SCHEDULE INDICATES THAT THE BATHROOM RECEPTACLE | | | WILL BE ON A 15 AMP CIRCUIT. A MINIMUM OF ONE 20 AMPERE | | | BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM | | | RECEPTACLE OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER | | | OUTLETS. PROVIDE CORRECTION. NEC 210.11(C)(3) , FBC RE | | | E3703.4 | | | 7. SHOW LOCATION OF MINI-SPLIT UNIT ON ELECTRICAL PLAN. | | | PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR SERVICING | | | OF A/C EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER | | | CODE. NEC 210.63; FBC RE E3901.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2020-01-03 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-12-17 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2019-12-18 14:17:57 | RESUB ROUTED TO PPETTY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-11-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-11-27 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-11-08 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-08-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-14 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-11 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-11-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-11-26 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-25 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2019-11-26 06:55:49 | MU-2019-028391-0000. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-08-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-14 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-13 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2019-08-14 08:10:00 | PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-11-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-11-26 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-11-25 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-08-09 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-08-09 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2020-01-03 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2020-01-03 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-11-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-11-21 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-11-21 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2019-11-21 18:15:26 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE SIZING ON THE SANITARY ISOMETRIC IS NOT CODE | | | COMPLIANT 3" IS REQUIRED TO THE WATER CLOSET THE ISO | | | SHOWS 2" THEN REDUCES TO 11/2" THEN BACK UP TO 2" FOR | | | THE VENT IT SHALL REMAIN 2" ALL THE WAY THRU THE ROOF | | | 11/4 SHALL NOT BE USED ON SANITARY ISOMETRIC PER FBC | | | RES P2713.1 BATHTUB WASTE OUTLETS AND OVERFLOWS. | | | BATHTUBS SHALL BE EQUIPPED WITH A WASTE OUTLET AND AN | | | OVERFLOW OUTLET. THE OUTLETS SHALL BE CONNECTED TO | | | WASTE TUBING OR PIPING NOT LESS THAN 11/2 INCHES (38 | | | MM) IN DIAMETER. THE WASTE OUTLET SHALL BE EQUIPPED | | | WITH A WATER-TIGHT STOPPER. | | | P2714.1 SINK WASTE OUTLETS. SINKS SHALL BE PROVIDED | | | WITH WASTE OUTLETS NOT LESS THAN 11/2 INCHES (38 MM) IN | | | DIAMETER. A STRAINER, CROSSBAR OR OTHER DEVICE SHALL BE | | | PROVIDED TO RESTRICT THE CLEAR OPENING OF THE WASTE | | | OUTLET. | | | P3005.1.4 | | | | | | 2. PROVIDE DETAIL FOR SHOWER PAN SHOWING COMPLIANCE | | | WITH FBC RES P2709.1, P2709.2 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2019-08-09 |
Time |
06:21 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2019-08-08 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2019-08-09 06:24:48 | 8/9/2019 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1) SHOW LOCATION OF HOT WATER HEATER | | | | | | 2) REVISE PLUMBING ISOMETRIC TO MEET MINIMUM FBC 2017 | | | | | | | | | ATELYO BELISLE | | | PLUMBING INSPECTOR / | | | PLUMBING PLANS EXAMINER | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6695 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-27 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-11-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-11-27 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-26 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-07-26 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2019-07-26 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-07-26 11:09:52 | ************ZONING REVIEW FAILED********** | | | | | | PROVIDE A COPY OF SURVEY. | | | | | | WITH CONVERSION OF GARAGE INTO A DEN, WHERE WILL THE | | | REQUIRED PARKING BE LOCATED? | | | | | | ADDITIONAL COMMENTS MAY FOLLOW ADDITIONAL REVIEW. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|